Nova StatStrip Glucose Hospital Meter System Recalled for Software Defect
Nova Biomedical is recalling StatStrip Glucose Hospital Meter Systems due to a software defect that may cause patient glucose results to be assigned to the wrong medical record.
What this means for you
Highest-severity recall. Risk of serious injury or death is documented or strongly suspected. Stop using the product now and follow the agency's instructions.
Our severity reasoning: The source text explicitly states the agency has classified this as a Class I recall, which mandates a severity score of 5 per the rubric.
Plain-English summary
Nova Biomedical Corporation is recalling the StatStrip Glucose Hospital Meter System, Model No. 63685. The recall involves 20,616 units distributed worldwide, including the United States and 22 foreign countries. The affected software versions range from 0.00.13.10 through 1.5.14.25.
The recall is due to a software synchronization and timing issue in the barcode scanning and patient data processing component. This defect causes the device to intermittently retain a previously scanned barcode, including patient identification and quality control barcodes, when a new barcode is scanned. As a result, the prior barcode information remains displayed on the screen for the current test. If an operator accepts this incorrect information, the current patient's glucose result may be assigned to the previous patient's medical record, while the current patient's record receives no result. This can lead to inappropriate clinical interventions based on erroneous data, particularly for critically ill patients, neonates, and infants. The defect does not affect the analytical accuracy of the glucose measurements themselves.
Healthcare facilities and users of the StatStrip Glucose Hospital Meter System should contact Nova Biomedical Corporation for instructions on how to resolve the software defect. The agency has classified this as a Class I recall, indicating a reasonable probability that use of the product will cause serious adverse health consequences or death.
The recalled product
- Product
- StatStrip Glucose Hospital Meter System. Model No: 63685. Glucose test system.
- Manufacturer
- Nova Biomedical Corporation
- Affected units
- 20,616
Distribution
Distributed nationwide across the United States.
Related recalls
Same manufacturer · Nova Biomedical Corporation
See all →- SevereNova Biomedical StatStrip Glucose Hospital Meter System Recalled for Software Defect
FDA (Devices) · 2026-09-23
- HighNova Biomedical Recalls StatStrip Glucose Meters Due to Software Defect
FDA (Devices) · 2026-09-23
- HighNova Biomedical StatStrip Glucose Meter Recalled for Data Error
FDA (Devices) · 2026-09-23
- CriticalNova Biomedical Recalls StatStrip Glucose Meters Due to Software Defect
FDA (Devices) · 2026-09-23
- SevereBlood Glucose Ketone Meter Firmware Bug Causes Inaccurate Test Results
FDA (Devices) · 2025-01-01
Same hazard · data integrity
See all →- HighGE Healthcare Recalls Workflow Core Services V8 Due to Data Association Errors
FDA (Devices) · 2026-09-23
- HighGE Healthcare Recalls Centricity PACS Software Due to Data Association Errors
FDA (Devices) · 2026-09-23
- HighGE Healthcare Recalls Centricity Enterprise Archive Software Due to Data Association Errors
FDA (Devices) · 2026-09-23
Similar recalls
- SevereNova Biomedical StatStrip Glucose Hospital Meter System Recalled for Software Defect
FDA (Devices) · 2026-09-23
- CriticalNova Biomedical Recalls StatStrip Glucose Meters Due to Software Defect
FDA (Devices) · 2026-09-23
- SevereGlucose Hospital Meter Software Bug Transmits Inaccurate Results
FDA (Devices) · 2025-01-01
- SevereBlood Glucose Ketone Meter Firmware Bug Causes Inaccurate Test Results
FDA (Devices) · 2025-01-01
- SevereBlood glucose ketone meter software bug causes erroneous result transmission
FDA (Devices) · 2025-01-01
- SevereNova Hospital Blood Glucose Meters Recalled for Battery Swelling and Leakage
FDA (Devices) · 2014-01-15