The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-2728-2018·Announced 2018-08-15

Howmedica Recalls 180 Radial Stem Implants Due to Performance Concerns

Howmedica Osteonics Corp. is recalling 180 sterile-packed radial stem implants because literature reviews indicate a higher revision rate than other similar devices.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: The recall is classified as FDA Class II. The hazard involves a medical device that may not perform as expected, leading to a higher revision rate, which fits the criteria for a risk-of-harm product where specific injury reports are not detailed in the source text.

Plain-English summary

Howmedica Osteonics Corp. is recalling 180 units of the radial stem implant #2 (Sterile packed). This orthopedic implant is used for the replacement of the proximal end of the radius in the Stryker rHead Radial Head and Uni-Elbow system. The specific product code is RHA-S260.

The recall was initiated because a literature review identified that the revision rate for this device is higher than that of other proximal radial head replacement devices. The source text notes that the product may not perform at the expected level post-surgery.

The affected units were distributed nationwide in the United States. Patients who have received this implant should contact their healthcare provider for further evaluation and guidance.

The recalled product

Product
radial stem implant #2 (Sterile packed). Orthopedic implant for replacement of the proximal end of the radius in the Stryker rHead Radial Head and Uni-Elbow system.
Affected units
180

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (1)

  • RHA-S260

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 70 recalled by Howmedica Osteonics Corp. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 70 products in this recall →

Similar recalls