The Recall Desk
HighFDA (Devices)·Z-2727-2018·Announced 2018-08-15

Howmedica Recalls Radial Stem Implants Due to Higher Revision Rates

Howmedica Osteonics Corp. is recalling 544 radial stem implants because literature reviews indicate higher revision rates than other similar devices.

What this means for you

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: The recall is classified as FDA Class II and involves a medical device with performance issues (higher revision rates) that pose a risk of harm, but no specific injuries or illnesses are reported in the source text.

Plain-English summary

Howmedica Osteonics Corp. is recalling 544 units of the radial stem implant #2 (Sterile packed). This orthopedic implant is used for the replacement of the proximal end of the radius in the Stryker rHead Radial Head and Uni-Elbow system. The product was distributed nationwide in the United States.

The recall was initiated because a literature review identified that the revision rate for this device is higher than that of other proximal radial head replacement devices. The source text notes that the product may not perform at the expected level post-surgery.

Patients who have received this implant should contact their healthcare provider for further evaluation. The recall is classified as Class II by the FDA.

The recalled product

Product
radial stem implant #2 (Sterile packed). Orthopedic implant for replacement of the proximal end of the radius in the Stryker rHead Radial Head and Uni-Elbow system.
Affected units
544

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (1)

  • RHA-S2

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 70 recalled by Howmedica Osteonics Corp. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 70 products in this recall →