Da Vinci surgical system operative components with E-brake retainer pin defect
Intuitive Surgical recalls certain Da Vinci surgical system operative components due to a defective E-brake retainer pin that may fail to engage the E-brake, potentially causing uncontrolled motion and patient injury.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 4/5 (Severe).
The hazard poses a serious risk of illness, injury, or structural failure. Stop using the product immediately and contact the manufacturer for a refund or repair.
Our severity reasoning: This is an FDA Class II recall of a medical device with potential for serious patient injury including tissue injury, crushing injury, and bleeding. Although no hospitalization reports are cited in the source, the mechanism of failure (uncontrolled motion during surgery) presents substantial risk of serious harm, meeting the Severe threshold.
Plain-English summary
Intuitive Surgical, Inc. is recalling Da Vinci ASSY, PSS, SP1098 operative components (Part Number 380601) distributed worldwide. The recall affects 454 units identified by the listed serial numbers.
The defect involves an E-brake retainer pin that may not function correctly. In the event of a structural column failure, the defective pin would prevent proper E-brake engagement, potentially resulting in uncontrolled motion of the surgical system. Additionally, if the pin moves or backs out of position, it may cause restricted column range of motion and/or uncontrolled motion.
These failures could cause patient tissue injury, crushing injury, or bleeding. Healthcare facilities using affected units should contact Intuitive Surgical for instructions on identifying their systems and obtaining corrective action.
The affected serial numbers are listed in the UDI documentation (UDI: 00886874114605). Worldwide distribution includes the United States and multiple countries including Belgium, Denmark, Sweden, France, Japan, Germany, Israel, Switzerland, South Korea, Czech Republic, Austria, United Kingdom, Italy, Spain, Ireland, Saudi Arabia, Greece, Taiwan, Australia, China, Turkey, Poland, United Arab Emirates, Hong Kong, and Romania.
The recalled product
- Product
- Da Vinci ASSY, PSS, SP1098, Part Number: 380601
- Manufacturer
- Intuitive Surgical, Inc.
- Affected units
- 454
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- UDI: 00886874114605. Serial Numbers: 605408
- 606848
- 612328
- 628399
- 609353
- 614073
- 617794
- 616769
- 10008062
- 635659
- 631694
- 638771
- 641430
- 694998
- 645433
- 643209
- 954097
- 656203
- 764644
- 656319
Distribution
Related recalls
Same manufacturer · Intuitive Surgical, Inc.
See all →- Moderateda Vinci SP Instrument Arm Drape may detach during surgical procedures
FDA (Devices) · 2026-07-22
- HighDa Vinci 5 tower may unintentionally activate the infrared handheld camera
FDA (Devices) · 2026-06-10
- SevereIntuitive 8 mm SureForm 30 Gray Reloads Incomplete Staple Defect
FDA (Devices) · 2026-05-13
- Highda Vinci X and Xi Surgical Systems Recalled for Manipulator Arm Screw Breakage
FDA (Devices) · 2026-05-13
- Highda Vinci double fenestrated grasper recalled over broken grip cables
FDA (Devices) · 2026-04-08
Same hazard · uncontrolled motion
See all →- HighSurgical staplers recalled over a malformed cover tube press
FDA (Devices) · 2025-11-19
- HighVATS lobectomy stapler boxes recalled over a malformed cover tube press
FDA (Devices) · 2025-11-19
- HighX-ray C-arm Tabletop Recalled for Risk of Uncontrolled Motion
FDA (Devices) · 2024-05-15
- SevereSenhance Robotic Surgical System uncontrolled arm motion malfunction
FDA (Devices) · 2023-11-08
- HighMedical beds with motorized wheels face uncontrolled motion risk
FDA (Devices) · 2022-06-01
Similar recalls
- SevereIntuitive Surgical Recalls da Vinci SP Systems Due to Defective Capacitors
FDA (Devices) · 2020-02-12
- HighIntuitive Surgical Recalls da Vinci Patient Side Manipulator Assemblies
FDA (Devices) · 2013-12-11
- HighIntuitive Surgical Recalls da Vinci Xi Surgical Systems Due to Brake Screw Issue
FDA (Devices) · 2017-07-05
- HighSurgical robot console motors recalled over an error that locks ergonomics
FDA (Devices) · 2025-12-31
- HighIntuitive Recalls 17 da Vinci SP Surgical Systems Due to Software Anomaly
FDA (Devices) · 2020-06-10
- ModerateIntuitive da Vinci SP Surgical System Cannula Mount Button Recall
FDA (Devices) · 2020-02-05