Siemens MRI Systems Recalled for Potential Coil Heating During Imaging
Siemens is recalling 370 MRI systems because the Flex Large 4 Coil can heat up in the electronic housing when positioned off-center.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (potential burn injury from heating) where injury has not yet been reported, fitting the High severity criteria.
Plain-English summary
Siemens Medical Solutions USA, Inc. is recalling 370 units of the Magnetom Skyra, Verio, Spectra, and Biograph MMR Nuclear Magnetic Resonance Imaging Systems. The recall involves specific model numbers including 10276755, 10684333, 10684334, 10432915, 10655588, and 10433372. These systems were distributed nationwide in the United States, including Washington, DC, and Puerto Rico.
The recall is issued because the Flex Large 4 Coil (part No. 8625761) can heat up in the area of the electronic housing, specifically the white plastic lids, when positioned off-center in the left-right direction and at an off-center position with respect to the head-foot direction. This positioning is used for certain imaging procedures, such as hip and shoulder imaging.
Healthcare facilities and users of these MRI systems should contact Siemens Medical Solutions USA, Inc. for further instructions on how to address this issue. The source text does not report any specific injuries or illnesses associated with this defect.
The recalled product
- Product
- Siemens Magnetom Skyra, Verio, Spectra and Biograph MMR Nuclear Magnetic Resonance Imaging System and Tomographic Imager
- Manufacturer
- Siemens Medical Solutions USA, Inc
- Category
- Medical Device — MRI Systems
- Hazard
- Affected units
- 370
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (6)
- Model numbers: 10276755 (Verio)
- 10684333 (Verio Dot)
- 10684334 (Verio Dot upgrade)
- 10432915 (Skyra)
- 10655588 (Spectra)
- and 10433372 (Biograph mMR)
Distribution
Related recalls
Same manufacturer · Siemens Medical Solutions USA, Inc
See all →- ModerateARTIS icono biplane medical imaging system detector lift malfunction
FDA (Devices) · 2026-07-08
- HighARTIS icono floor Medical Imaging System Detector Movement Loss Recall
FDA (Devices) · 2026-07-08
- ModerateARTIS icono ceiling medical imaging monitor suspension system
FDA (Devices) · 2026-07-08
- HighARTIS Icono Ceiling Model 11328100 Loss of Movement Capability Recall
FDA (Devices) · 2026-07-08
- HighARTIS pheno systems may display zero dose while dose is applied
FDA (Devices) · 2026-06-10
Same hazard · burn injury
See all →- SevereVQQQ Gas Patio Heaters Recalled for Fire and Burn Hazards
CPSC · 2026-10-22
- HighThomas Built Buses Recalls 2027 Saf-T-Liner C2 School Buses
NHTSA · 2026-10-21
- SevereDR Power Trimmer Mowers Recalled for Fire and Burn Hazards
CPSC · 2026-10-08
- SevereSnow Peak Recalls Propane Fireplace Inserts and Lava Rocks
CPSC · 2026-10-08
- SevereHyundai and Genesis Recall Vehicles Due to Front Seat Fire Risk
NHTSA · 2026-10-08
Similar recalls
- HighSiemens MAGNETOM MRI Systems Recalled Due to Magnetic Table Cover Hazard
FDA (Devices) · 2016-05-11
- HighSiemens MAGNETOM Skyra MRI Devices Recalled for Quench Venting System Defect
FDA (Devices) · 2019-08-28
- HighSiemens X-ray Table Recalled for Fire Hazard in Power Supply
FDA (Devices) · 2024-07-03
- HighSiemens Symbia S Series Nuclear Medicine Imaging Systems Recalled for Overheating Risk
FDA (Devices) · 2015-08-26
- HighSiemens Combi Dockable Neurosurgery Table Recalled for Height Drop Risk
FDA (Devices) · 2017-04-19
- HighSiemens Recalls Multix Fusion X-Ray Systems Due to Table Tilt Risk
FDA (Devices) · 2016-10-12