Zyno Medical Administration Sets Recalled Due to Inverted Pinch Clamp Defect
Zyno Medical LLC is recalling administration sets where an inverted pinch clamp may cause blood to be drawn from the patient instead of delivering fluid.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device defect that poses a risk of harm (blood withdrawal instead of fluid delivery) where injury has not yet been reported, fitting the 'High' severity criteria for risk-of-harm products.
Plain-English summary
Zyno Medical LLC is recalling Zyno Medical Administration Sets (Product Code: B2-70072-F) due to a manufacturing defect involving the pinch clamp. The recall affects 360 cases (18,000 units) distributed in Massachusetts. The specific lot numbers involved are 18046309 and 18026344.
The defect occurs when the pinch clamp is assembled in an inverted position. If a secondary set is used with the primary set, this configuration causes fluid from the distal end of the administration set to be pumped toward the proximal end. Consequently, instead of delivering medication to the patient, blood may be drawn from the patient if there is sufficient space in the drug container to hold the extra volume of fluid. This risk exists if the reversed pinch clamp is not identified by the user.
Healthcare providers and facilities should check their inventory for the affected product code and lot numbers. If the product is found, it should be removed from use and returned to Zyno Medical LLC in accordance with the recall instructions.
The recalled product
- Product
- Zyno Medical Administration Set -105"ADMIN SET 20DP W/FILTER 2YSITES CLMP- For Use with Zyno Medical Infusion pumps or Gravity Feed Product Code: B2-70072-F
- Manufacturer
- Zyno Medical LLC
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (2)
- Lot Numbers: 18046309
- 18026344 UDl/UPC/GTIN: 00814371020204
Distribution
Distributed in 1 state:
Part of a larger recall action
This product is one of 2 recalled by Zyno Medical LLC under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · Zyno Medical LLC
See all →- SevereZ-800F Infusion System Recall Due to Unvalidated Software Versions
FDA (Devices) · 2025-06-18
- SevereZ-800W Infusion System Recalled for Unvalidated Software Installation
FDA (Devices) · 2025-06-18
- SevereZ-800 Infusion System recalled for unverified software installation
FDA (Devices) · 2025-06-18
- SevereZ-800WF Infusion System software verification defect recall
FDA (Devices) · 2025-06-18
- ModerateZ-800WF Infusion Pumps Recalled for Software Incompatibility Issue
FDA (Devices) · 2024-12-04
Similar recalls
- HighZyno Medical Administration Set Recalled for Potential Filter Leaking
FDA (Devices) · 2016-10-05
- HighICU Medical Recalls IV Administration Sets with Incorrect Drop Cannula
FDA (Devices) · 2020-05-13
- ModerateZyno Medical Recalls Z-800 Volumetric Infusion Systems for Software Update
FDA (Devices) · 2013-04-10
- HighICU Medical Recalls 7-inch Intravascular Administration Sets with Incorrect Spin Collar
FDA (Devices) · 2018-04-18
- HighICU Medical Recalls Intravascular Administration Sets Due to Manufacturing Defect
FDA (Devices) · 2020-10-28
- SevereICU Medical Recalls Intravascular Administration Sets Due to Seal Defect
FDA (Devices) · 2020-10-28