t:slim X2 Insulin Pumps Recalled for Software Issues Affecting Blood Sugar Management
Tandem Diabetes Care is recalling approximately 8,399 t:slim X2 insulin pumps due to software malfunctions that may affect blood sugar control. A software update is available to resolve the issues.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: This is an FDA Class II recall of a critical medical device with potential for serious health consequences (hypoglycemia, hyperglycemia, and diabetic ketoacidosis), but no reported illnesses or injuries are documented in the source material. The risk is significant but not yet confirmed through actual patient harm.
Plain-English summary
Tandem Diabetes Care Inc is recalling several versions of the t:slim X2 insulin pump, including models with Dexcom G5 integration, Basal-IQ technology, and Control-IQ technology. The recalled pumps are affected by software malfunctions that can cause four types of failures: Non-Volatile Memory malfunction, inaccurate battery life display, touchscreen remaining on, and unexpected open-loop operation. These issues could result in improper insulin delivery, leading to hypoglycemia, hyperglycemia, or diabetic ketoacidosis.
Approximately 8,399 affected pumps have been distributed throughout the United States, Puerto Rico, the U.S. Virgin Islands, and internationally in Australia, New Zealand, and South Africa. The recall affects the following software versions: t:slim X2 version 6.4.1 and earlier, t:slim X2 with Dexcom G5 versions 5.2.1 and 5.2.2, t:slim X2 with Basal-IQ versions 6.3.0.1, 6.4, and 6.4.1, and t:slim X2 with Control-IQ versions 7.4 and 7.4.3.
The FDA has classified this as a Class II recall. Tandem Diabetes Care has made a software update available that resolves these issues. Consumers with affected pumps should contact Tandem Diabetes Care to obtain and apply the software update.
The recalled product
- Product
- t:slim X2 insulin pump; t:slim X2 insulin pump with Dexcom G5; t:slim X2 insulin pump with Basal-IQ technology; t: slim x2 insulin pump with the Control-IQ Technology
- Manufacturer
- Tandem Diabetes Care Inc
- Category
- Medical Device — Insulin Pump
- Affected units
- 8,399
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (8)
- Insulin Pump/Software Versions: t:slim X2 insulin pump/6.4.1 and earlier
- t:slim X2 insulin pump with Dexcom G5/5.2.1
- 5.2.2
- t:slim X2 insulin pump with Basal-IQ technology/6.3.0.1
- 6.4
- 6.4.1
- t: slim x2 insulin pump with the Control-IQ Technology/7.4
- 7.4.3
Distribution
Part of a larger recall action
This product is one of 2 recalled by Tandem Diabetes Care Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 2 products in this recall →Related recalls
Same manufacturer · Tandem Diabetes Care Inc
See all →- HighTandem t:slim iOS App Recall Due to CGM Pairing Failure
FDA (Devices) · 2026-10-07
- HighTandem insulin pump Czech guide inverted a key connection instruction
FDA (Devices) · 2026-04-01
- CriticalInsulin pumps recalled over false vibration motor failure stopping delivery
FDA (Devices) · 2025-11-12
- HighInsulin pumps recalled over software defect causing unexpected correction bolus
FDA (Devices) · 2025-10-29
- HighInsulin pump app recalled over defect in right-to-left language settings
FDA (Devices) · 2025-10-01
Same hazard · software malfunction
See all →- HighPhilips PIC iX Essentials Patient Information System Software Recall
FDA (Devices) · 2026-09-23
- HighPhilips Patient Information Center iX Software Malfunction Recall
FDA (Devices) · 2026-09-23
- HighAbbott Merlin pacemaker programmer may fail to terminate threshold test
FDA (Devices) · 2026-06-17
- HighMedtronic SynchroMed Flex Infusion Programmer Software Application
FDA (Devices) · 2026-05-20
- ModerateProtocol Configuration Tool software v1.3.0 for Hamilton AutoLys STAR
FDA (Devices) · 2026-04-29
Similar recalls
- Severet:slim X2 Insulin Pump Software Defect Affecting Glucose Delivery
FDA (Devices) · 2025-04-23
- HighInsulin pumps recalled over software defect causing unexpected correction bolus
FDA (Devices) · 2025-10-29
- HighTandem t:slim X2 Insulin Pump Battery Display May Cause Insulin Delivery Failure
FDA (Devices) · 2022-06-22
- SevereInsulin pump app may crash and drain battery, risking insulin delivery interruption
FDA (Devices) · 2024-05-15
- CriticalInsulin pumps recalled over malfunction that stops insulin delivery and alerts
FDA (Devices) · 2025-09-03
- HighTandem t:slim G4 Insulin Pump Recalled for Inaccurate Battery Readings
FDA (Devices) · 2018-07-25