ARJOHUNTLEIGH Recalls Concerto and Basic Shower Trolleys Due to Safety Catch Failure
ARJOHUNTLEIGH is recalling 669 Concerto and Basic Shower Trolleys because a mechanical failure in the safety catch could cause the side support to open, posing a risk of patient falls and injuries.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (patient falls) where injury has not yet been reported, and the agency classification is Class II without explicit reports of hospitalization or death, fitting the 'High' severity criteria.
Plain-English summary
ARJOHUNTLEIGH POLSKA Sp. z.o.o. is recalling 669 units of the Concerto & Basic Shower Trolly, including specific model numbers and spare parts for the safety catch. The recall affects serial numbers ranging from P0512263 to P0551621, as well as specific individual serial numbers listed in the agency documentation. The devices were distributed in the United States across 15 states and in numerous international locations.
The firm identified that the safety catches on these trolleys may exhibit a mechanical failure, specifically a break in one of the arms of the safety catch. In certain circumstances, this failure may cause the side support to open unintentionally. This malfunction creates a potential risk of a patient falling, which could lead to various types of injuries.
Healthcare facilities and consumers should stop using the affected shower trolleys and contact ARJOHUNTLEIGH for instructions on how to return the devices or obtain replacements. The recall is classified as Class II by the FDA, indicating a reasonable probability that the use of the product could cause temporary or medically reversible adverse health consequences.
The recalled product
- Product
- Concerto & Basic Shower Trolly, Model Numbers BAB1000-01 (UDI: (01)05055982788083), BAB1000CON6102 [(01)05056097364483], BAB1007-01 [(01)05055982796255], BAB1101-01 [(01)05055982787949], BAB1102-01 [(01)05055982796156], BAB1103-01 [UDI: (01)05055982796163], BAB1107-01…
- Manufacturer
- ARJOHUNTLEIGH POLSKA Sp. z.o.o.
- Affected units
- 669
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (11)
- Concert & Basic Shower trolleys Serial Numbers: P0512263 to P0551621
- P0279164
- SEE0643339
- SEE0605124
- P0249502
- SEE045073
- SEE0520032
- 1106000338
- SEE0348065
- P0422951
- P0232526
Distribution
Related recalls
Same manufacturer · ARJOHUNTLEIGH POLSKA Sp. z.o.o.
See all →- HighArjo Tenor patient lift actuators may lose the ability to hold load
FDA (Devices) · 2026-04-22
- HighArjo medical beds with unintended wheel movement recalled
FDA (Devices) · 2024-01-03
- HighArjo Medical Beds Recalled Due to Unintended Wheel Movement
FDA (Devices) · 2024-01-03
- SevereSara Plus Active Floor Lift Recalled for Smoke and Ignition Risk
FDA (Devices) · 2022-06-01
- HighArjo Citadel Beds: Power Cord Wear May Cause Electrical Hazard
FDA (Devices) · 2021-10-06
Same hazard · fall injury
See all →- SevereMedline Bariatric Rollator Recalled Due to Front Wheel Assembly Disconnect Risk
FDA (Devices) · 2026-10-14
- High
- HighForest River Recalls 2026-2027 Dynamax Isata RVs for Bunk Mat Alignment
NHTSA · 2026-09-23
- HighForest River Recalls 2026-2027 Dynamax Isata RVs Due to Ladder Defect
NHTSA · 2026-09-23
- HighBritax Recalls Infant Car Seats Due to Handle Detachment Risk
NHTSA · 2026-08-20
Similar recalls
- HighArjo Concerto Basic Shower Trolley Recalled for Loose Bolts
FDA (Devices) · 2016-04-20
- HighArjoHuntleigh Recalls Chorus Mobile Patient Lifters Due to Injury Risk
FDA (Devices) · 2012-07-18
- HighArjoHuntleigh Recalls Tenor Mobile Passive Lifts Due to Bolt Breakage Risk
FDA (Devices) · 2014-09-24
- SevereArjohuntleigh RotoProne Therapy System Recalled for Buckle Release Issue
FDA (Devices) · 2019-02-13
- High
- HighTarget Recalls Room Essentials Shower Stools Due to Fall Hazard
CPSC · 2021-05-26