Navilyst NAMIC Convenience Kit Recall Due to Sterility Risk
Navilyst Medical is recalling NAMIC Convenience Kits because expiration dating is not fully supported by testing, which may result in a sterility breach and increased infection risk.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (sterile medical device) where injury has not yet been reported, fitting the 'High' severity criteria for potential infection risk without confirmed cases.
Plain-English summary
Navilyst Medical, Inc. is recalling 2,409 units of NAMIC Convenience Kits, LEFT HEART, REF/Catalog No. 600604412. These sterile, single-use devices are intended for use in Fluid Management and/or Invasive Pressure Monitoring Systems. The affected lots were distributed nationwide in the United States, as well as in Canada and Guam.
The recall was initiated because the labeled expiration dating of the affected product is not fully supported by shelf life verification testing. This deficiency may result in a sterility breach. The use of a Fluid Management Convenience Kit where sterility has been breached may result in an increased risk of infection.
Healthcare providers and facilities should stop using the affected lots immediately and contact Navilyst Medical for further instructions. Consumers should not use these products if they have them in their possession.
The recalled product
- Product
- NAMIC Convenience Kit, LEFT HEART, UPN H7496006044121, REF/Catalog No. 600604412, STERILE, Rx ONLY ---For single use only. --- Device Listing Number D136588. Product Usage: NAMIC Convenience Kits are intended to be used in Fluid Management and/or Invasive Pressure Monitoring…
- Manufacturer
- Navilyst Medical, Inc
- Affected units
- 2,409
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (20)
- Lots 4226931
- 4244899
- 4269158
- 4269159
- 4279292
- 4309494
- 4316972
- 4326577
- 4344275
- 4384465
- 4398606
- 4413579
- 4413580
- 4436613
- 4436614
- 4447485
- 4447486
- 4475711
- 4481532
- 4485378
Distribution
Distributed nationwide across the United States.
Part of a larger recall action
This product is one of 60 recalled by Navilyst Medical, Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 60 products in this recall →Related recalls
Same manufacturer · Navilyst Medical, Inc
See all →- HighNavilyst Medical Recalls NAMIC Convenience Kits Due to Sterility Concerns
FDA (Devices) · 2015-03-04
- HighNavilyst Medical Recalls NAMIC Convenience Kits Due to Sterility Concerns
FDA (Devices) · 2015-03-04
- HighNavilyst NAMIC Convenience Kits Recalled for Sterility Concerns
FDA (Devices) · 2015-03-04
- HighNavilyst Medical Recalls NAMIC Convenience Kits Due to Sterility Concerns
FDA (Devices) · 2015-03-04
- HighNavilyst Medical Recalls NAMIC Convenience Kits Due to Sterility Concerns
FDA (Devices) · 2015-03-04
Same hazard · infection
See all →- SevereMedtronic Recalls Grafton DBM Products Due to Donor Microbial Presence
FDA (Devices) · 2026-10-21
- SevereMedtronic Recalls Grafton DBM Allografts Due to Donor Microbial Presence
FDA (Devices) · 2026-10-21
- SevereStryker Bard EP XT Decapolar Steerable Diagnostic EP Catheter Recalled for Sterile Barrier Breach
FDA (Devices) · 2026-10-14
- SevereSafeguard US Operating LLC Recalls Compression Bandages Due to Degradation
FDA (Devices) · 2026-10-14
- HighFDA Recalls Performance Pro Nitrile Gloves Due to Defects
FDA (Devices) · 2026-10-07
Similar recalls
- HighNavilyst Medical Recalls PICC Kits Due to Potential Sterility Compromise
FDA (Devices) · 2014-10-15
- ModerateNAMIC Fluid Management Convenience Kits Recalled for Assembly Defect
FDA (Devices) · 2018-04-25
- HighMEDLINE namic Cardiovascular Kit Variants Recalled for Lack of Sterility
FDA (Devices) · 2024-05-22
- ModerateNavilyst Medical Recalls PICC Kits Due to Potential Sterility Issues
FDA (Devices) · 2014-10-15
- HighNavilyst Medical Recalls PICC Kits with Compromised Sterility
FDA (Devices) · 2014-10-15
- HighNavilyst Medical Recalls Vaxcel PICC Catheters Due to Hemolysis Risk
FDA (Devices) · 2016-06-22