Villa Sistemi Medicali Recalls Apollo EZ X-Ray Table Due to Chain Failure
Villa Sistemi Medicali is recalling one Apollo EZ X-ray table because the angulation chain may fail early due to metal fatigue.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a mechanical component failure in a medical device where injury has not yet been reported, fitting the rubric for risk-of-harm products without reported injury.
Plain-English summary
Villa Sistemi Medicali S.P.A. is recalling one unit of the Apollo EZ remote-controlled X-ray table, Model Number 9784152036, with Serial Number 13101261. The recall is being conducted by the U.S. Food and Drug Administration under recall number Z-0766-2020.
The recall is issued because testing revealed that the angulation chain may fail before its expected 10-year lifetime due to metal fatigue under severe workload conditions. An amendment to the Instructions for Use and Service Manual has been issued to prescribe the replacement of the angulation chain after 8 years of service.
The affected unit was distributed in the United States in the states of AL, AZ, CA, CO, CT, DC, FL, IA, IL, IN, LA, MA, MD, MI, MN, MO, MS, NJ, NY, OH, OK, PA, TN, TX, UT, and Puerto Rico. Users of this specific equipment should contact the manufacturer or their service provider to arrange for the necessary chain replacement.
The recalled product
- Product
- Apollo EZ, Model Number 9784152036 - Product Usage: The Apollo EZ remote-controlled table is X-ray equipment that can be used to perform general radiographic and fluoroscopic examinations. The system is a fixed position type. The movements of the table and tube support are…
- Manufacturer
- Villa Sistemi Medicali S.P.A.
- Category
- Medical Device — X-Ray Equipment
- Hazard
- Affected units
- 1
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Serial Numbers: 13101261
Distribution
Part of a larger recall action
This product is one of 4 recalled by Villa Sistemi Medicali S.P.A. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 4 products in this recall →Related recalls
Same manufacturer · Villa Sistemi Medicali S.P.A.
See all →- HighVilla Sistemi Medicali Recalls Apollo DRF X-ray Tables Due to Chain Failure
FDA (Devices) · 2020-01-08
- HighVilla Sistemi Medicali Recalls Apollo X-ray Tables Due to Chain Failure Risk
FDA (Devices) · 2020-01-08
- HighVilla Sistemi Medicali Recalls Juno DRF X-Ray Systems Due to Chain Failure
FDA (Devices) · 2020-01-08
- SevereVilla Sistemi Medicali Recalls Apollo X-Ray Systems Due to Footrest Detachment
FDA (Devices) · 2017-03-15
- SevereVilla Sistemi Medicali Recalls Apollo EZ X-Ray Systems Due to Footrest Detachment
FDA (Devices) · 2017-03-15
Same hazard · mechanical failure
See all →- SevereCanon Medical Alphenix INFX-8000C/B5 Recalled for Tabletop Shift Risk
FDA (Devices) · 2026-10-14
- ModerateLeMaitre TufTex Over-the-Wire Embolectomy Catheter Recalled for Balloon Failure
FDA (Devices) · 2026-10-14
- HighMirion Captus 4000e Thyroid Uptake System Recalled for Spring Arm Failure
FDA (Devices) · 2026-09-23
- HighIMRIS ORT300 Operating Room Table Recalled for Mechanical Failure Risk
FDA (Devices) · 2026-09-02
- HighIMRIS ORT200 Operating Room Table Recalled for Mechanical Failure Risk
FDA (Devices) · 2026-09-02
Similar recalls
- SevereVilla Sistemi Medicali Recalls Apollo EZ X-Ray Systems Due to Footrest Detachment
FDA (Devices) · 2017-03-15
- SevereVilla Radiology Systems Recalls Apollo EZ X-Ray Systems Due to Injury Risk
FDA (Devices) · 2017-02-01
- SevereVilla Sistemi Medicali Recalls Apollo X-Ray Systems Due to Footrest Detachment
FDA (Devices) · 2017-03-15
- SevereApollo DRF X-ray Systems Recalled Due to Footrest Detachment Hazard
FDA (Devices) · 2017-03-15
- SevereVilla Radiology Systems Recalls Apollo X-Ray Systems Due to Injury Risk
FDA (Devices) · 2017-02-01
- SevereVilla Radiology Systems Recalls Apollo DRF X-Ray Systems Due to Injury Risk
FDA (Devices) · 2017-02-01