B Braun APEX Compounding System Control Panel Module Recalled for Accuracy Issues
B Braun Medical is recalling 248 APEX Compounding System Control Panel Modules because they may fail to detect air bubbles, potentially resulting in inaccurate drug compounding.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device intended for intravascular administration where a defect could lead to inaccurate drug dosing. Per the rubric, this is classified as High (3) because it is a risk-of-harm product where injury has not yet been reported.
Plain-English summary
B Braun Medical, Inc. is recalling 248 units of the APEX Compounding System Control Panel Module (REF: 601224, Product Code AX1000). The affected units are those with Software Version 1.0.5.57 or earlier. The product is intended for intravascular administration to a patient.
The recall was initiated because the compounding system may not immediately interrupt the process or alert the user to the presence of an air bubble exceeding 3% of the ordered volume for an ingredient. This failure could result in a compounded drug that does not meet the specified accuracy range for an individual ingredient.
The affected units were distributed nationwide in the United States, including in the states of AL, AZ, CA, CO, CT, FL, GA, IA, IL, LA, MA, MD, MI, MN, MO, NC, NH, NJ, NV, NY, OH, OK, PA, TN, TX, and WA. Healthcare facilities and users should identify affected units by checking the software version and contact B Braun Medical for further instructions.
The recalled product
- Product
- APEX Compounding System Control Panel Module, REF: 601224, Product Code AX1000 - Product Usage: intended for intravascular administration to a patient.
- Manufacturer
- B Braun Medical, Inc.
- Affected units
- 248
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- All APEX Compounding System with Software Version 1.0.5.57 or earlier
Distribution
Part of a larger recall action
This product is one of 3 recalled by B Braun Medical, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 3 products in this recall →Related recalls
Same manufacturer · B Braun Medical, Inc.
See all →- CriticalB. Braun Recalls Sodium Chloride Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-16
- LowB Braun Recalls Discofix Stopcock Sets Due to Incorrect Expiration Date
FDA (Devices) · 2026-09-09
- SevereB. Braun Recalls Lactated Ringer's Injection Due to Particulate Matter
FDA (Drugs) · 2026-09-02
- ModerateB. Braun UPMC double catheter trays contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
- ModerateB. Braun spinal epidural kits contain Mastisol with cracking tubing
FDA (Devices) · 2026-06-10
Same hazard · inaccurate dosing
See all →- HighPresource Neurological Surgical Kits Recalled for Syringe Design Defect
FDA (Devices) · 2024-07-17
- HighCardinal Health Cardiac Catheterization Kits Recalled for Potential Syringe Design Defect
FDA (Devices) · 2024-07-17
- HighPresource surgical kits recalled for syringe design defect risk
FDA (Devices) · 2024-07-17
- HighMedline Luer Slip Syringes Recalled for Inaccurate Volume Delivery
FDA (Devices) · 2024-06-12
- HighB Braun APEX Compounding System Control Panel Module Recalled
FDA (Devices) · 2020-12-30
Similar recalls
- HighB. Braun Recalls 26-Lead Transfer Sets for Valve Orientation Defect
FDA (Devices) · 2018-07-11
- SevereCareFusion Alaris Pump Module Recalled for Software Errors
FDA (Devices) · 2020-03-11
- HighMetrix AUTOCOMP6 XP High Speed Compounder Recalled for Dispensing Accuracy Issues
FDA (Devices) · 2016-08-03
- SevereBaxter ExactaMix Inlets Recalled for Particulate Contamination Risk
FDA (Devices) · 2024-09-25
- CriticalBaxter pharmaceutical compounding inlets recalled for particulate matter contamination
FDA (Devices) · 2024-09-25
- SevereBaxter EXACTAMIX pharmaceutical compounding inlets recalled for particulate contamination
FDA (Devices) · 2024-09-25