Synthes LCP Drill Sleeve Recall Due to Connection and Alignment Issues
Synthes, Inc. is recalling LCP Drill Sleeve 1.5 Drill Bits because they may fail to attach to plates, potentially causing surgical delays or off-center drilling.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a medical device defect that could lead to surgical complications such as screw or plate loosening, fitting the criterion for risk-of-harm products where injury has not yet been reported.
Plain-English summary
Synthes, Inc. is recalling 567 units of the LCP Drill Sleeve 1.5 Drill Bit 1.1mm (Part Number 03.114.001). These devices are used in the LCP Modular Mini Fragment System for the fixation of small bones and small bone fragments. The affected lot numbers are FT00227, 9972971, H028400, H161606, and H288454.
The recall was initiated because the drill sleeve may have difficulty attaching to the plate. If the sleeve does not connect intraoperatively, it could cause a delay in the surgery. Additionally, if the pilot hole is drilled without the sleeve, the hole may be off-center, which could result in the loosening of the screw and/or plate.
The affected products were distributed to the United States, Canada, and Germany. Healthcare providers and facilities should stop using these specific devices and contact Synthes, Inc. for instructions on how to return or replace the affected units.
The recalled product
- Product
- LCP Drill Sleeve 1.5 Drill Bit 1.1mm Part Number 03.114.001 Used in LCP Modular Mini Fragment System, for fixation of small bones and small bone fragments
- Manufacturer
- Synthes, Inc.
- Affected units
- 567
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (1)
- Lot numbers FT00227 9972971 H028400 H161606 H288454
Distribution
Distribution scope not specified by the agency.
Related recalls
Same manufacturer · Synthes, Inc.
See all →- ModerateSynthes Recalls MatrixNEURO Screws Due to Incorrect Body Clip Labeling
FDA (Devices) · 2020-08-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes 2.4mm Sterile Locking Screw Recall Due to Packaging Defect
FDA (Devices) · 2020-02-05
- ModerateSynthes Recalls 2.4mm Sterile Locking Screws Due to Packaging Defect
FDA (Devices) · 2020-02-05
Same hazard · device malfunction
See all →- SevereMedtronic MiniMed Flex Insulin Pumps Recalled for Failed Verification Tests
FDA (Devices) · 2026-10-14
- ModerateWilson-Cook Recalls Hemospray Endoscopic Hemostat Due to Adherence Issues
FDA (Devices) · 2026-09-23
- HighDatex-Ohmeda Aisys CS2 Anesthesia Systems Recalled for Gas Mixer Defect
FDA (Devices) · 2026-09-23
- HighDatex-Ohmeda Aisys CS2 Anesthesia Systems Recalled for Gas Mixer Defect
FDA (Devices) · 2026-09-23
- HighDatex-Ohmeda Et Control Software Recalled for Anesthetic Delivery Interruption
FDA (Devices) · 2026-09-23
Similar recalls
- ModerateSynthes 1.1mm Drill Bit Recalled for Incorrect MR Safety Labeling
FDA (Devices) · 2016-07-20
- HighSynthes 1.5MM Surgical Drill Bit Recalled Due to Sterilization Concerns
FDA (Devices) · 2024-03-13
- SevereSynthes Cannulated Drill Bits Recalled for Potential Breakage During Use
FDA (Devices) · 2015-06-10
- HighSynthes Spine Drill Bit Recalled for Potential Drill Stop Slippage
FDA (Devices) · 2013-02-13
- HighSynthes Recalls 4.5 mm LCP Proximal Tibia Plate Systems
FDA (Devices) · 2016-04-06
- ModerateSynthes 2.7 mm Locking Screws Recalled for Mislabeling as 2.4 mm
FDA (Devices) · 2015-11-04