The Recall Desk

Hazard

Surgical Delay recalls

132 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
132
Critical
0
Severe
4
Most recent
2026-08-12

Of the 132 surgical delay recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 4 (3%) are Severe.

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all surgical delay recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

1–25 of 132

  • HighFDA (Devices)·Z-2859-2026·2026-08-12

    Anti-Torque Instrument in Vector Pedicle Screw System Recalled

    Innovasis, Inc is recalling 5 Anti-Torque instruments (part LS-749) in the Vector Pedicle Screw System due to an undersized condition that may prevent proper engagement during spinal surgery, causing delays.

    Product
    Anti-Torque, Vector, Part: LS-749 part of Vector Pedicle Screw System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2192-2025·2025-08-06

    Phasor neurosurgical drills may have a reverse battery orientation

    The Phasor Drill, used in neurosurgical procedures, is being recalled because it may have a reverse battery orientation, which may increase surgical time. 1,064 units are affected.

    Product
    Phasor Drill, REF: 2.70S, 3.20L, 4.50, 5.30, 6.35
    Category
    Medical Device
    Distribution
    29 states
  • HighFDA (Devices)·Z-1403-2025·2025-03-26

    Shoulder Prosthesis Stem Excess Material Prevents Proper Surgical Assembly

    Zimmer Orthopedics recalls shoulder prosthesis models due to excess material in the taper that prevents proper surgical assembly. Five complaints reported.

    Product
    Comprehensive Shoulder Stem, Comprehensive Micro Stem, Comprehensive Mini Stem; uncemented shoulder prosthesis, Model Nos. 113605, 113606, 113607, 113627
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1215-2025·2025-03-05

    Anatomic Lateral Fibula Plate locking screw malfunction during surgery

    Tyber Medical is recalling 220 A.L.P.S. mvX Anatomic Lateral Fibula Plates due to complaints that the locking screw passes through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- Product Name: ANATOMIC LAT FIB PLATE 10H LT Anatomic Lateral Fibula Plate, 10-Hole, Left. Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770708101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1214-2025·2025-03-05

    Orthopedic Surgical Plates Recalled Due to Intra-Operative Locking Screw Malfunction

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates nationwide due to reports that locking screws may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H RT: Anatomic Lateral Fibula Plate, 8-hole, Right Indicated for use in Fixation of fractures of the distal tibia Model/Catalog Number: 77070802
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1210-2025·2025-03-05

    Orthopedic fibula plate locking screw failure during surgery

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates due to locking screw passing through the locking hole intra-operatively, causing surgical delays. The recall affects 397 units distributed nationwide.

    Product
    A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 4H RT: Anatomic Lateral Fibula Plate, 4-hole, Right Model/Catalog Number: 770708042
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1219-2025·2025-03-05

    Orthopedic tibia plate locking screw failure causes surgical delays

    Tyber Medical recalls A.L.P.S. mvX Medial Tibia plates; the locking screw can pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-MEDIAL TIBIA PLATE 6H LT-Medial Tibia Plate, 6-Hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715061
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1224-2025·2025-03-05

    A.L.P.S. mvX Medial Tibia Plate Locking Screw Malfunction Recall

    Tyber Medical recalls 208 units of A.L.P.S. mvX Medial Tibia Plates due to locking screws that can pass through the locking hole during surgery, causing surgical delays. No patient injuries have been reported.

    Product
    A.L.P.S. mvX--MEDIAL TIBIA PLATE 12H RT-Medial Tibia Plate, 12-Hole, Right Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715122
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1216-2025·2025-03-05

    Anatomic lateral fibula plate locking screw failure during surgery

    Tyber Medical A.L.P.S. mvX anatomic lateral fibula plates (219 units nationwide) have a defect where the locking screw can pass through its locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 10H RT- Anatomic Lateral Fibula Plate, 10-Hole, Right. Intended forFixation of fractures of the distal tibia Model/Catalog Number: 770708102 Product Description:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2415-2024·2024-07-31

    Electrosurgical Generators Olympus ESG-410 May Fail to Power On

    Olympus is recalling 86 ESG-410 Electrosurgical Generators because they may fail to power on during use, potentially delaying treatment or prolonging surgery.

    Product
    ESG-410 Electrosurgical Generator- In conjunction with electrosurgical accessories intended for cutting and coagulation of tissue in open, laparoscopic , and endoscopic surgeries Model/Catalog Number: WA91307C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2135-2024·2024-06-19

    CORI Surgical System Software Error Causes Tracking Array Flickering

    The CORI Starter Kit surgical system may experience display flickering from a software tracking error, potentially causing surgical delays during orthopedic procedures.

    Product
    CORI Starter Kit, Real Intelligence CORI, CORI STARTER KIT - UNIVERSAL.Intended to assist the surgeon in providing software-defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures Product Numbers: (1) ROB10000
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1916-2024·2024-06-05

    Surgical screwdrivers recalled for failure to engage with implant screws

    Synthes surgical screwdrivers are being recalled because they lack a required relief cut and will not engage properly with 1.3mm and 1.5mm implant screws, potentially delaying surgery. The defect affects 261 units distributed in the US and Canada.

    Product
    STARDRIVE SCRWDRVR SHFT/T4 50MM/SELF-RETAINING/HXC-Intended for tightening, loosening, or removing of screw implants during orthopaedic surgery. Part Number: 03.130.010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1709-2024·2024-05-08

    Zimmer Distal Lateral Fibular Plate may fail to lock screws securely

    Zimmer's Distal Lateral Fibular Plate has threading defects that may prevent screws from locking properly. The defect could go unnoticed during surgery and cause loss of fixation.

    Product
    ZPLP (Zimmer Periarticular Locking Plate System) Distal Lateral Fibular Plate, Right, 4 Holes, 80 MM, Sterile- Indicated for temporary internal fixation and stabilization of osteotomies and fractures Item Number: 47-2357-017-04
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1701-2024·2024-05-08

    Olympus POWERSEAL Surgical Sealer Recalled for Non-Functional Seal Activation

    Olympus POWERSEAL curved jaw sealers may fail to deliver energy during initial activation, causing incomplete seal cycles and surgical delays. Affected units should be removed from service immediately.

    Product
    POWERSEAL 5 mm, 44 cm, Curved Jaw Sealer and Divider, Double Action is indicated for use in general surgery and such surgical specialties as urologic, colorectal, bariatric, vascular, thoracic, and gynecologic. Model/Catalog Number: PS-0544CJDA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0382-2024·2023-11-29

    Biomet Compress Device Anchor Plug Recall - Metal Burrs May Extend Surgery

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through, potentially extending operative time.

    Product
    Compress Device Short Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178560
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0377-2024·2023-11-29

    Biomet Anchor Plugs Recalled: Metal Burrs Prevent Proper Assembly

    Biomet's Compress Device Segmental Anchor Plugs are being recalled due to metal burrs in assembly holes. The defect prevents drill pins from passing through, potentially extending surgical time during implantation procedures.

    Product
    Compress Device Segmental Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178414
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0384-2024·2023-11-29

    Compress Device Short Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (22 MM) used in orthopedic surgery because they may contain metal burrs in the transverse holes that could prevent drill or pin passage and extend surgical procedures.

    Product
    Compress Device Short Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178564
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0098-2024·2023-10-18

    Reverse Shoulder Prosthesis Screws May Have Incorrect Size

    Reverse shoulder prosthesis packages labeled as containing 5mm x 30mm screws may instead contain incorrect 3.5mm x 30mm screws. Using the wrong size screws could cause surgical delay and inadequate fixation.

    Product
    REVERSE PROSTHESIS SHOULDER SYSTEM, SCREW, LOCKING BONE, RSP, 5mmX30mm long, REF: 506-03-130
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-2347-2023·2023-08-16

    LINK MP Monoblock Hip Stem Trial Instruments May Require Increased Removal Force

    LINK MP Monoblock Hip Stem trial instruments may require increased force to remove after impaction, potentially prolonging surgery for affected patients.

    Product
    LINK MP Monoblock Hip Stem, Trial Stem Instruments, Size 16 - Indicated for patients with Mobility-limiting diseases, fractures or defects of the hip joint or proximal femur Item Number: 136-116/00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1426-2023·2023-05-03

    Lateral lumbar spine implant plate may disassemble during surgery

    SPINEART's JULIET Ti LL lateral lumbar implant plates may disassemble during preparation or implant removal, causing surgical delays. The FDA is recalling 544 affected units distributed across eight US states.

    Product
    JULIET Ti LL, LATERAL LUMBAR TI-LIFE PLATE SMALL, REF: JLT-PL 02 08-S, JLT-PL 02 10-S, JLT-PL 02 12-S, JLT-PL 02 14-S, JLT-PL 02 16-S; JULIET Ti LL, LATERAL LUMBAR TI-LIFE PLATE LARGE, REF: JLT-PL 04 08-S, JLT-PL 04 10-S, JLT-PL 04 12-S, JLT-PL 04 14-S, JLT-PL 04 16-S, JLT-PL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0125-2023·2022-11-02

    Hip Liner Implants Mixed with Knee Inserts in Packaging

    Encore Medical is recalling EMPOWR hip liner implants because boxes may contain knee inserts instead. This packaging error could delay surgeries. Four units affected in six US states.

    Product
    EMPOWR Acetabular System, Liner, 10 deg Hooded, HXe+ 40H, REF: 942-01-40H. Orthopedic implant component.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0008-2023·2022-10-12

    Hammertoe Continuous Compression Implant Kit Drill Pin Incompatibility

    Synthes is recalling Hammertoe Continuous Compression Implant (CCI) Kits because the drill pin is incompatible with the included drill template, which may delay surgery or cause soft tissue damage and adverse tissue reactions.

    Product
    Hammertoe Continuous Compression Implant (CCI) Kit Part Number: 46.239.001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1419-2022·2022-07-27

    Orthopedic Surgical Guide with Defective Spring Subject to Corrosion

    DePuy Orthopaedics is recalling 872 units of the ATTUNE Measured Sizing and Rotation Guide due to a manufacturing defect. A galvanized steel spring was used instead of stainless steel, which may cause corrosion and surgical complications.

    Product
    ATTUNE Measured Sizing and Rotation Guide-to size the femur and align rotation of the bone cuts in preparation for the femoral implant Part Number: 254400525
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0910-2022·2022-04-20

    Orthopedic Surgical Instrument Kit Recalled for Improper Driver Fit

    The Nextra Hammertoe Correction System surgical kit is being recalled due to an oversized driver that cannot properly connect to and remove from the implant. This defect can delay surgery.

    Product
    Nextra Hammertoe Correction System 4.5 Middle 3.2 Proximal Kit SKU: NX-4532K Orthopedic surgical instrument
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0484-2022·2022-01-19

    GLOBAL UNITE STD STEM orthopedic implant manufacturing defect recall

    DePuy Orthopaedics is recalling GLOBAL UNITE STD STEM orthopedic implants due to undersized spigot bore diameter that may prevent proper removal during revision surgery, risking surgical delay and bone damage.

    Product
    GLOBAL UNITE STD STEM SZ 8 Part Number: 110008100
    Category
    Medical Device
    Distribution
    Distributed nationwide