The Recall Desk

Manufacturer

Nova Bus

36 recalls in our database name Nova Bus as the manufacturing or recalling firm.

What the numbers show

Total
36
Critical
0
Severe
15
Most recent
2021-05-14

Of the 36 recalls from Nova Bus we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 15 (42%) are Severe.

About this listing

The manufacturer string comes from the agency’s own source notice — for FDA recalls, the “recalling firm” field; for NHTSA recalls, the vehicle manufacturer; for CPSC recalls, the firm-of-record on the joint press release. A single corporate family can appear under multiple manufacturer strings as agency notices aren’t standardized on a canonical name. If you don’t see recalls you expect, try a parent-company search or a broader full-text search.

Severity scores below are computed from the agency’s classification and the recall text, never from manufacturer behaviour or history. Many manufacturers issue routine corrective actions (software updates, labelling corrections) that are correctly scored low — having recalls on this list isn’t inherently a quality signal.

1–25 of 36

  • HighNHTSA·21V351000·2021-05-14

    Nova Bus Recalls 2016-2020 LFS Models Due to Fuel Rail Leak Risk

    Nova Bus is recalling 2016-2020 LFS and LFS Artic vehicles because a defective sealing washer may cause high-pressure fuel leaks, increasing fire risk.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC, LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V568000·2020-09-21

    Nova Bus Recalls LFS Models Due to Power Steering Pipe Separation Risk

    Nova Bus is recalling 2019-2021 LFS and LFS ARTIC transit buses because power steering pipes may separate, causing fluid leaks and loss of steering assist.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC, LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V511000·2019-07-02

    Nova Bus Recalls 2014-2017 LFS Models Due to Seat Hardware Defect

    Nova Bus is recalling 2014-2017 LFS and LFS Artic buses because improperly tightened seat hardware may cause cantilever seats to drop, increasing injury risk.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V274000·2019-04-05

    Nova Bus Recalls 2011-2019 LFS City Buses for Fire Risk

    Nova Bus is recalling 2011-2019 LFS city buses because an engine door fan electrical connector may overheat and cause a fire.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V829000·2018-11-26

    Nova Bus Recalls 2013-2018 LFS Artic Buses for Software Fault

    Nova Bus is recalling 2013-2018 LFS Artic transit buses because a software fault may cause the vehicle to operate at zero velocity and lack dampening, increasing crash risk.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V670000·2018-09-26

    Nova Bus Recalls 2017 LFS Hybrid Buses for Transmission Defect

    Nova Bus is recalling 2017 LFS Hybrid and LFS Arctic Hybrid buses because pressure switches may fail, causing a loss of drive and increasing crash risk.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V299000·2018-05-07

    Nova Bus Recalls 2015-2017 LFS Models Due to Brake Component Defect

    Nova Bus is recalling 2015-2017 LFS and LFS Artic transit buses because a brake guide pin may break, potentially causing loss of braking ability or tire pressure.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V117000·2018-02-17

    Nova Bus Recalls 2013 LFS Transit Buses for Cooling System Defect

    Nova Bus is recalling 2013 LFS transit buses because a transmission oil cooler failure could cause hot coolant to leak into the passenger area, posing a risk of injury.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·17V323000·2017-05-16

    Nova Bus Recalls 2016 LFS Artic Buses for Throttle Control Defect

    Nova Bus is recalling 2016 LFS Artic transit buses because a network communication loss may cause the computer to apply full throttle without driver input.

    Product
    NOVA BUS — NOVA BUS LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V191000·2016-04-05

    Nova Bus Recalls 2010-2015 LFS Transit Buses for Seat Belt Defect

    Nova Bus is recalling 2010-2015 LFS transit buses because missing welds on seat J-Brackets may allow seat belt anchorages to separate, increasing injury risk in a crash.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·16V135000·2016-03-04

    Nova Bus Recalls 2014-2016 LFS Models for Wiper Arm Defect

    Nova Bus is recalling 863 LFS and LFS Artic buses from 2014-2016 because a wiper idler arm pin may strip, causing wipers to stop working and reducing visibility.

    Product
    NOVA BUS — NOVA BUS LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V735000·2015-11-05

    Nova Bus Recalls Transit Buses Due to Door Pinch Hazard

    Nova Bus is recalling 2010-2015 LFS and 2013-2015 LFS Artic transit buses because a passenger counter sensor may pinch a passenger's arm in the door.

    Product
    NOVA BUS — NOVA BUS NOVA LFS, LFS, LFS ARTIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V350000·2015-06-05

    Nova Bus Recalls 2001-2004 LFS Buses for Parking Brake Hose Defect

    Nova Bus is recalling 250 model year 2001-2004 LFS buses because incorrectly connected air hoses may delay parking brake application, increasing crash risk.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V079000·2015-02-09

    Nova Bus Recalls 2009 LFS Transit Buses for Brake Hose Fitting Defect

    Nova Bus is recalling 2009 LFS transit buses because damaged brake hose crimping rings may fail, affecting braking performance and increasing crash risk.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·15V077000·2015-02-09

    Nova Bus Recalls 2007-2009 LFS Transit Buses for Fire Risk

    Nova Bus is recalling 2007-2009 LFS transit buses because a battery cable may short to ground, increasing the risk of a fire.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V076000·2015-02-09

    Nova Bus Recalls 2008 LFS Transit Buses for Emergency Exit Defect

    Nova Bus is recalling 2008 LFS transit buses because surrounding material may interfere with opening emergency exit windows, increasing injury risk.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·15V078000·2015-02-09

    Nova Bus Recalls 2009 LFS Transit Buses Due to Wiring Defect

    Nova Bus is recalling 2009 LFS transit buses because an incorrectly wired main power relay circuit may defeat circuit protection, increasing the risk of fire.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide

About this company

Community-sourced company facts from Wikidata, not from any recall agency. This is background on the corporate entity — it says nothing about the recall(s) listed on this page, which come from the agency source notice above.

Nova Bus

Canadian bus manufacturer

Country
Sweden
Founded
1993
Parent company
AB Volvo

Official website