The Recall Desk

Hazard

Fluid Leak recalls

98 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
98
Critical
0
Severe
36
Most recent
2026-10-07

Of the 98 fluid leak recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 36 (37%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all fluid leak recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

76–98 of 98

  • HighFDA (Devices)·Z-2161-2014·2014-08-13

    ICU Medical Recalls Arterial Monitoring Kits Due to Fluid Leak Risk

    ICU Medical is recalling 200 arterial monitoring kits because a component connection may crack, causing a fluid leak.

    Product
    Single Transpac IT Monitoring Kit w/03 ml Flush Device, Needleless Valve, Macrodrip, Item No. 011-46106-29 Transpac Trifurcated monitoring kit with Safeset Reservoir, squeeze flush and sampling ports. The monitoring kit is intended for measuring and montoring of fluid…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2070-2014·2014-07-23

    Excelsior Medical Recalls Sterile Triple Lead Tubing Sets Due to Leak Risk

    Excelsior Medical is recalling sterile triple lead tubing sets because a molding defect may allow fluid leaks or air entry during use.

    Product
    Excelsior Medical Sterile Triple Lead Tubing Set and Sterile Heavy Duty Triple Lead Tubing Set. To be used with the Pharm-Assist Dispensing Pump. Used for drug reconstitution and/or fluid transfer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V211000·2014-04-18

    BMW Recalls 2013 R 1200 GS Motorcycles for Transmission Seal Defect

    BMW is recalling 2013 R 1200 GS motorcycles because transmission pressure may push the output seal out of place, causing oil to leak onto the rear tire and increasing crash risk.

    Product
    BMW — BMW R 1200 GS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V152000·2014-03-31

    GM Recalls 2014-2015 Trucks and SUVs for Transmission Oil Fire Risk

    General Motors is recalling specific 2014-2015 Chevrolet and GMC vehicles because a transmission oil cooler line may not be securely seated, creating a potential fire hazard.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO, YUKON, TAHOE, SUBURBAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0148-2014·2013-11-13

    Fresenius Liberty Cycler Recalled for Fluid Leak and Contamination Risk

    Fresenius Medical Care is recalling Liberty Cyclers because fluid leaks may contaminate dialysate, potentially causing peritonitis.

    Product
    Fresenius Liberty¿ Cycler Part Number: RTLR180111 Product Usage: The Liberty cycler is a portable device designed to perform acute and chronic peritoneal dialysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2251-2013·2013-09-25

    Churchill Medical Recalls Vygon 14 Microbore Extension Sets

    Churchill Medical Systems is recalling 13,100 Vygon 14 Microbore Extension Sets because the tubing may disconnect from the male luers.

    Product
    Vygon 14 Microbore Extension Set with Bionector, CMS-814-1. The CMS-814-1 is a 14 inch extension set used to administer IV fluids.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0158-2013·2012-10-31

    Sorin Gish Reducer Connectors Recalled for Potential Fluid Leakage

    Sorin Group USA is recalling specific lots of Gish Reducer Connectors due to a molding defect that may cause fluid leaks or air entrainment.

    Product
    Gish 3/8 x 1/2" Reducer Connector with Luer fitting, Item Numbers: EC2180S, Lot Numbers: 1108900099, 1119900091, 1203700129, 1208600013, 1219200107, Exp. Dates: 3/31/14, 7/31/14, 2/28/15, 3/31/15, 7/31/15. Product Usage: The connectors are indicated for use in connecting…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V430000·2012-09-04

    Lamborghini Recalls 2004-2006 Gallardo for Steering Pipe Leak Fire Risk

    Lamborghini is recalling 1,491 model year 2004-2006 Gallardo vehicles because high-pressure steering pipes may leak fluid, posing a fire risk if exposed to an ignition source.

    Product
    LAMBORGHINI — LAMBORGHINI GALLARDO
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12E025000·2012-06-29

    Thunderbird Brake Hose Recall for Non-Compliant Federal Safety Standards

    Thunderbird Headquarters is recalling specific brake hoses for 1955-1966 Ford Thunderbirds that fail to meet federal safety standards, posing a risk of brake fluid leaks.

    Product
    SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V267000·2012-06-13

    BMW Recalls X5 and X6 Vehicles for Steering Gear Fire Risk

    BMW is recalling 2012-2013 X5 and 2013 X6 vehicles because a steering gear defect may cause power steering fluid to leak onto hot exhaust parts, increasing the risk of an engine compartment fire.

    Product
    BMW — BMW X6, X5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·12V222000·2012-05-17

    Honda Recalls Accord and Acura TL for Power Steering Fire Risk

    Honda is recalling 625,762 vehicles because a deteriorating power steering hose can leak fluid onto a hot catalytic converter, potentially causing an under-hood fire.

    Product
    HONDA — HONDA, ACURA ACCORD, TL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V591000·2011-12-19

    Chevrolet Captiva Recall: Power Steering Fluid Leak Fire Risk

    General Motors is recalling 2011-2012 Chevrolet Captiva vehicles because the power steering fluid reservoir may leak and cause a fire.

    Product
    CHEVROLET — CHEVROLET CAPTIVA SPORT, CAPTIVA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11E046000·2011-11-07

    Baldwin Filters Recalls Oil and Fuel Filters for Diesel Engines

    Baldwin Filters is recalling certain oil and fuel filters for small diesel engines because gasket material may fail, causing fluid loss, power loss, or fire.

    Product
    FUEL SYSTEM, OTHER:FUEL FILTER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·11V127000·2011-02-23

    PACCAR Recalls Kenworth and Peterbilt Trucks Due to Oil Leak Fire Risk

    PACCAR is recalling specific Kenworth and Peterbilt trucks because a loose engine oil filter cap may leak oil onto hot exhaust parts, creating a fire hazard.

    Product
    KENWORTH — KENWORTH, PETERBILT T2000, T660, T700, T800
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10E051000·2010-10-27

    Advics Brake Master Cylinders Recalled for Potential Brake Fluid Leak

    Advics is recalling brake master cylinders in certain Toyota and Honda vehicles because a seal may dry out and leak fluid, potentially degrading braking performance.

    Product
    SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:MASTER CYLINDER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·10V174000·2010-04-29

    Honda Recalls 2004-2008 Acura TSX for Power Steering Hose Fire Risk

    Honda is recalling 2004-2008 Acura TSX vehicles because a deteriorating power steering hose could leak oil onto a hot exhaust pipe, potentially causing an under-hood fire.

    Product
    ACURA — ACURA TSX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateNHTSA·10V132000·2010-04-06

    Nova Bus Recalls LFS Models Due to Incorrect Radiator O-Rings

    Nova Bus is recalling 2007-2010 LFS buses because incorrect O-rings in the roof-mounted radiator may leak hydraulic oil. Dealers will replace the parts free of charge.

    Product
    NOVA BUS — NOVA BUS NOVA LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·02078·2002-08-20

    Arctic Cat Recalls 2002 ATVs Due to Brake Fluid Leak Risk

    Arctic Cat is recalling about 45,000 2002 ATVs because a pressure switch leak can cause brake failure, posing a risk of serious injury or death.

    Product
    Arctic Cat ATVs with the following model names: 250, 300, 300 Massey Ferguson, 375, 400, 400i, 500, TBX 500 and 500i
    Category
    Vehicle
    Distribution
    Distributed nationwide