The Recall Desk

Hazard

Crash Risk recalls

5,748 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
5,748
Critical
0
Severe
2,789
Most recent
2026-09-11

Of the 5,748 crash risk recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,789 (49%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all crash risk recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

2801–2825 of 5748

  • SevereNHTSA·19V515000·2019-07-05

    Ford Recalls Focus Vehicles Due to Potential Engine Stall Risk

    Ford is recalling certain 2012-2017 Focus vehicles because a malfunctioning valve may cause the engine to stall while driving, increasing crash risk.

    Product
    FORD — FORD FOCUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V512000·2019-07-03

    Winnebago Forza Motorhomes Recalled for Storage Door Defect

    Winnebago is recalling 2017-2019 Forza motorhomes because the exterior storage compartment door may unexpectedly open while driving, increasing crash risk.

    Product
    WINNEBAGO — WINNEBAGO FORZA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19E044000·2019-07-03

    DLT Recalls CravenSpeed Fiat Short Shifter Shafts for Breakage Risk

    DLT, LLC is recalling CravenSpeed Fiat Short Shifter shafts for 2011-2019 Fiat 500 vehicles because improper manufacturing may cause the shaft to break, increasing crash risk.

    Product
    FIAT — FIAT 500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V509000·2019-07-02

    Volvo Trucks Recalls 2018-2020 Models Due to Transmission Fuse Defect

    Volvo Trucks is recalling 2018-2020 VAH, VHD, VNL, and VNR models because a fuse may blow, preventing the transmission from shifting and increasing crash risk.

    Product
    VOLVO — VOLVO VNR, VAH, VHD, VNL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V505000·2019-07-01

    Forest River Recalls 2019 Rockport Trucks Due to Brake Controller Wiring

    Forest River is recalling 2019 Rockport work trucks with optional trailer brake controllers due to improper wiring that may prevent trailer brakes from activating.

    Product
    FOREST RIVER — FOREST RIVER ROCKPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V496000·2019-06-27

    Mazda Recalls 2016 MX-5 Vehicles for Detaching Skid Plate

    Mazda is recalling 2016 MX-5 vehicles because the skid plate and metal bracket may detach, creating a road hazard and increasing crash risk.

    Product
    MAZDA — MAZDA MX-5
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V497000·2019-06-27

    Mazda Recalls 2018-2019 Models for Potential Engine Stall Risk

    Mazda is recalling 262,220 vehicles due to a software error that may cause the engine to stall unexpectedly, increasing crash risk.

    Product
    MAZDA — MAZDA MAZDA3, CX-5, MAZDA6
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V492000·2019-06-26

    Jerr-Dan Heavy Duty Wrecker Recall for Remote Control Engine Shutdown

    Jerr-Dan is recalling 2018-2019 Heavy Duty Wreckers because the remote control system may cause the engine to shut down unexpectedly, increasing crash risk.

    Product
    JERR-DAN — JERR-DAN HEAVY DUTY WRECKER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V489000·2019-06-25

    Mercedes-Benz Metris Recalled for Potential Loss of Power Steering

    Daimler Vans USA is recalling 2018-2019 Mercedes-Benz Metris vehicles because a steering sensor defect may cause the electric power steering assist to deactivate, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ METRIS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V483000·2019-06-21

    Altec Aerial Devices Recalled for Air Brake System Defects

    Altec is recalling 2003-2019 aerial devices due to potential air brake pressure loss. Owners should contact dealers for free inspection and repair.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V486000·2019-06-21

    Oshkosh Recalls 2018-2019 S-Series Mixers Due to Steering Hose Error

    Oshkosh is recalling 2018-2019 S-Series Mixer vehicles because hydraulic hoses may be installed incorrectly, causing loss of steering assist and increasing crash risk.

    Product
    OSHKOSH — OSHKOSH S-SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V471000·2019-06-19

    Blue Bird Recalls 2018-2019 Electric School Buses for Software Defect

    Blue Bird is recalling 2018-2019 Vision and All American electric school buses because a software defect may cause the vehicle to lose drive and power steering.

    Product
    BLUE BIRD — BLUE BIRD VISION, ALL AMERICAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V472000·2019-06-19

    BMW Recalls 2008-2012 Models for Battery Cable Defect

    BMW is recalling specific 2008-2012 models because a battery cable connection may degrade, causing power loss and stalling.

    Product
    BMW — BMW M3, 328I, 328XI, 335D
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V467000·2019-06-18

    Isuzu Recalls 2018-2020 FTR and Chevrolet 6500XD for Steering Defect

    Isuzu is recalling 2018-2020 FTR and Chevrolet 6500XD vehicles because a steering stopper bolt jam nut may loosen, increasing the turning radius and crash risk.

    Product
    ISUZU — ISUZU, CHEVROLET FTR, 6500XD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V466000·2019-06-18

    SVO Group Recalls 2017-2018 Ford E-350 and E-450 Shuttle Buses

    SVO Group is recalling 2017-2018 Ford E-350 and E-450 shuttle buses because backup camera images may reverse, increasing crash risk.

    Product
    FORD — FORD E-450, E-350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V464000·2019-06-18

    Farber Recalls 2018 International 4300 Vehicles with Whelen Brake Lights

    Farber Specialty Vehicles is recalling 2018 International 4300 SBA vehicles equipped with Whelen brake lights that may illuminate without the brake pedal being pressed.

    Product
    INTERNATIONAL — INTERNATIONAL 4300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V463000·2019-06-18

    Farber Recalls 2017 Ford F-550 Vehicles Due to Brake Light Wiring Issue

    Farber Specialty Vehicles is recalling 2017 Ford F-550s with Whelen brake lights that may illuminate without the brake pedal being pressed, potentially confusing other drivers.

    Product
    FREIGHTLINER — FREIGHTLINER redundant FORD F550
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V456000·2019-06-14

    Autocar Recalls 2013-2018 Xpeditor Vehicles for Drive Shaft Support Defect

    Autocar is recalling 2013-2018 Xpeditor vehicles because the drive shaft support cross member may fail, increasing crash risk. Dealers will install additional support brackets free of charge.

    Product
    AUTOCAR — AUTOCAR XPEDITOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V457000·2019-06-14

    Mercedes-Benz Recalls AMG GT Vehicles for Driveshaft Separation Risk

    Mercedes-Benz is recalling 2016-2017 AMG GT vehicles because the carbon-fiber driveshaft may separate, causing a loss of drive and increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ AMG GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V462000·2019-06-14

    Caterpillar Recalls 2015-2019 Progress Rail Sky Trim Hi-Rail Vehicles

    Caterpillar is recalling 2015-2019 Progress Rail Sky Trim Hi-Rail vehicles because a support plate may block driver visibility and the boom may detach from the cradle while in motion.

    Product
    PROGRESSIVE RAIL SERVICES — PROGRESSIVE RAIL SERVICES SKY TRIM
    Category
    Vehicle
    Distribution
    Distributed nationwide