The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

39301–39325 of 40489

  • ModerateFDA (Devices)·Z-0487-2013·2012-12-19

    Roche LightCycler 1.2 Diagnostic Software Recalled for Device-Associated Issue

    Roche Molecular Systems is recalling LightCycler 1.2 software due to a device-associated diagnostic software issue. The recall covers 3,772 units distributed nationwide.

    Product
    LightCycler 1.2 (software version 3.5) is a Rapid PCR analyzer with real-time detection and/or quantification of a target NA (nucleic acid), as well as post-PCR analysis of the amplified NA by melting curve analysis with corresponding assays.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0488-2013·2012-12-19

    Roche Recalls LightCycler 2.0 Instrument Due to Diagnostic Software Issue

    Roche Molecular Systems is recalling 1,213 LightCycler 2.0 instruments due to a device-associated diagnostic software issue.

    Product
    LightCycler 2.0 Instrument (software version 4.1) is a Rapid PCR analyzer with real-time detection and/or quantification of a target NA (nucleic acid), as well as post-PCR analysis of the amplified NA by melting curve analysis.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0481-2013·2012-12-19

    Hospira Recalls Plum A+ Infusion Pumps Due to Reversed Volume Knob

    Hospira is recalling Plum A+ single channel infusion pumps because the volume control knob may function in reverse, causing alarm volume to increase when turned clockwise.

    Product
    Plum A+ Single Channel Infusion Pumps with Plug-and-Play Modules that provide wired Ethernet and wireless local area networking; Hospira, Inc., Lake Forest, IL 60045; pump list number 11971, module list numbers 12101, 12102 and 12393; pump list number 11973, module list number…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0513-2013·2012-12-19

    Mindray Recalls DPM 6 and 7 Patient Monitors for Software Limitations

    Mindray DS USA is recalling 124 DPM 6 and 7 patient monitors because specific calculation features may be unavailable.

    Product
    DPM 6/7 Patient Monitor Manufactured in China for : Mindray DS USA, Inc. 800 MacArthur Blvd. Mahwah, NJ 07430 USA. Intended to be used for monitoring, displaying, reviewing, storing and alarming of multiple physiological parameters including ECG (3-lead or 5-lead or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0517-2013·2012-12-19

    Quasar Bio-Tech Recalls Unapproved Baby Quasar Infrared LED Lamps

    Quasar Bio-Tech is recalling Baby Quasar and Baby Quasar Pink infrared LED lamps because the devices are unapproved by the FDA.

    Product
    Baby Quasar (LAB-001-D, BQ101) and Baby Quasar Pink (LAB-046-A BQ101-P) are infrared LED lamps that are labeled in part: "***BABY QUASAR***FOR YOUTHFUL RADIANT SKIN***Skin Rejuvenating System with Sequepulse***Manufactured by: Silver Bay, LLC; Made in the USA, with highest…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0482-2013·2012-12-19

    Hospira Plum A+ Infusion Pumps Recalled for Reversed Volume Control Knob

    Hospira is recalling Plum A+ Hyperbaric Infusion Pumps because the volume control knob may function in reverse, causing alarm volume to increase when turned clockwise.

    Product
    Plum A+ Hyperbaric Single Channel Infusion Pumps with Hospira MedNet Software and a Connectivity Engine peripheral module that provides wired Ethernet and wireless local networking, allowing the MedNet software to download drug libraries to the infuser and enable the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0504-2013·2012-12-19

    ConMed Recalls WANG Transbronchial Aspiration Needles Due to Fit Issues

    ConMed is recalling WANG Transbronchial Aspiration Needles because they may not fit through a 2.0 mm bronchoscope, causing minor inconvenience.

    Product
    WANG Transbronchial Aspiration Needles Cat. No. SW-121, WANG Cytology Needles, Central, Carinal and Mediastinal Regions, 21 g x 15 mm long needle. --- Common Name: Bronchoscope (flexible or rigid) and accessories. The ConMed WANG Transbronchial Aspiration Needles are designed…
    Category
    Medical Device
    Distribution
    14 states
  • SevereFDA (Devices)·Z-0467-2013·2012-12-12

    iwalk BiOM Battery and Charger Recalled for Overheating and Smoke Risk

    iwalk inc is recalling BiOM lower leg system batteries and chargers because they may overheat and smoke during charging.

    Product
    BiOM Rechargeable Li Ion 22.2 V Battery and BiOM Lithium Battery Charger sold as an accessory to the BiOM lower leg system: Product Number: 2001249 BiOM Battery Product Number: 2001240 BiOM Charger
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0447-2013·2012-12-12

    Natus Olympic Cool-Cap Recalled Due to Frozen Screen Malfunction

    Natus Medical is recalling 324 Olympic Cool-Cap systems because the control module screen may freeze, causing the device to stop cooling infants without visible alarm.

    Product
    The product has the Catalogue/Part number 60010. Olympic Cool-Cap System is a selective head cooling system for treatment of hypoxic-ischemic encephalopathy (HIE) in infants. A cooling water cap is placed on the infant's head and the body is warmed using radiant warmers.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0471-2013·2012-12-12

    Biomet Recalls OSS Knee Reamer Sleeves Due to Sticking Risk

    Biomet is recalling 46 OSS Knee Reamer Sleeves because the thin shaft reamer may get stuck and fail to slide into the sleeve.

    Product
    OSS Reamer Sleeve REF132-472661 KNEE REAMER SLEEVE 8.0 THRU 12.5 STAINLESS STEEL The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0457-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    24 Fr 8mm Sft Flow Straight Wir The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0462-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip may detach and harm patients during surgery.

    Product
    24 Fr 8mm Soft Flow Ang W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0458-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip could detach and harm patients during surgery.

    Product
    24 Fr 8mm Sft Flow Straight The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0464-2013·2012-12-12

    Merit Medical Systems Recalls Custom Procedural Trays Due to Missing Tape

    Merit Medical Systems is recalling 83 custom procedural trays because clear protective tape was not applied during manufacturing.

    Product
    Custom Procedural Trays: Merit's Custom Total Hip Pack, K12T-05537, Merit's Total Knee Pack, K12T05538 A custom procedural tray is a combination of legally marketed medical devices placed into one container for the convenience of the user and used within the limits of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0475-2013·2012-12-12

    Philips Digital Diagnost Software Recall for Image Marker Error

    Philips is recalling Digital Diagnost Software R2.0.2 because a mirrored image marker can be mistaken for a patient side indicator.

    Product
    Philips Digital Diagnost Software Version R2.0.2 Product Usage: This system is used for making X-ray exposures for diagnostics
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0472-2013·2012-12-12

    Biomet Recalls OSS Knee Reamer Sleeves Due to Sticking Defect

    Biomet is recalling 36 OSS Knee Reamer Sleeves because the thin shaft reamer may get stuck and fail to slide into the sleeve.

    Product
    OSS Reamer Sleeve REF132-472662 KNEE REAMER SLEEVE 13.0 thru 20.0 STAINLESS STEEL The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0455-2013·2012-12-12

    Stryker Neptune 2 Rover Recall Due to Binding Casters

    Stryker is recalling 154 Neptune 2 Rover units because a castor design defect can cause binding, leading to operator strain and back pain.

    Product
    Neptune¿ 2 Rover - ULTRA ~230V ~ 50 Hz 12A REF 0702-002-000, Rx Caution, consult accompanying documents Consult instructions for use, Max Vacuum; 21.0 in-Hg, 530 mm-Hg, The Neptune Waste Management System consists of a mobile rover unit used to suction and collect fluid…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0474-2013·2012-12-12

    Biomet Recalls Bio-Modular Humeral Heads Due to Missing Ion Implantation

    Biomet, Inc. is recalling four Bio-Modular Humeral Heads because they are missing the ion implantation feature, which may cause increased wear and shorter implant life.

    Product
    Bio-Modular Humeral Head 48mm x 24mm Ti 6AI4V/Ion Implanted (Orthopedic Implant) Product Usage: The OSS Knee Reamer Sleeves are primarily used to guide the bullet tip of cylindrical reamers during the tibial preparation in OSS procedures. They are reusable.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0452-2013·2012-12-12

    Siemens IRON Flex Reagent Cartridges Recalled for Falsely Elevated Results

    Siemens Healthcare Diagnostics is recalling IRON Flex reagent cartridges because environmental iron contamination can cause falsely elevated test results.

    Product
    Dimension Vista(R) IRON Flex(R) reagent cartridge (K3085) The IRON method is an in vitro diagnostic test for the quantitative determination of iron in human serum and plasma on the Dimension Vista(R) System. Measurements of iron are used in the diagnosis and treatment of…
    Category
    Medical Device
    Distribution
    46 states
  • HighFDA (Devices)·Z-0466-2013·2012-12-12

    Philips and Neusoft Recall CT Scanners Due to Detaching Patient Table

    Philips and Neusoft are recalling 45 CT scanners because the patient table top can detach from the carrier, posing a risk of injury.

    Product
    NeuViz 16 Multi-Sliced CT Scanner System, part number 989605858501. NeuViz Dual series CT Scanner System, part number 989605651321 The NeuViz 16 CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0468-2013·2012-12-12

    Invivo Expression MRI Patient Monitoring System Recalled for Detached Caster Risk

    Invivo Corporation is recalling the Expression MRI Patient Monitoring System because a caster may detach during transport, causing the cart to fall.

    Product
    Invivo Corporation Expression MRI Patient Monitoring System. The Expression MRI Patient Monitoring System is intended for use by healthcare professionals to monitor vital signs for patients undergoing MRI procedures. The Patient Monitoring System also provides signals for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0453-2013·2012-12-12

    OmniGuide BP-ROBOTIC Fiber Recalled Due to Glue Joint Failure

    OmniGuide, Inc. is recalling 45 units of BP-ROBOTIC single-use fibers because a glue joint failure may cause the device to shift and fall into the patient.

    Product
    OmniGuide BP-ROBOTIC ( BeamPath Robotic), Single Use Cat. # BP-ROBOTIC The OmniGuide Fiber is indicated for the incision, excision, ablation, vaporization and coagulation of body soft tissues including intra-oral tissues. It is indicated in the medical specialties of general…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0459-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    18 Fr 6mm Sft Flow Angled Wire The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0461-2013·2012-12-12

    Terumo Recalls Sarns Aortic Cannulas Due to Plastic Flash Defect

    Terumo is recalling Sarns Aortic Cannulas because plastic flash at the tip may detach and harm patients during surgery.

    Product
    24 Fr 8mm Soft Flow Ang Wire W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-0460-2013·2012-12-12

    Terumo Recalls Sarns Soft-Flow Aortic Cannulas Due to Plastic Flash

    Terumo is recalling Sarns Soft-Flow Aortic Cannulas because plastic flash at the tip may detach and cause adverse patient effects.

    Product
    18 Fr 6mm Sft Flow Ang Wire W/L The Sarns Aortic Cannula is indicated for use in perfusion of the ascending aorta during cardiopulmonary bypass surgery. These devices are indicated for up to 6 hours of use.
    Category
    Medical Device
    Distribution
    27 states

Looking for a different category? Browse all recalls.