The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

33826–33850 of 40489

  • HighFDA (Devices)·Z-0922-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Remote Controls Due to Unintended Movement

    Trumpf Medical Systems is recalling JUPITER remote controls for operating tables because damaged units may cause unintended movement during surgery.

    Product
    IR remote control JUPITER / TS7500, Material no.1601927, Serial number: to (incl.) 102222333. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0920-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Cable Remote Controls

    Trumpf Medical Systems is recalling JUPITER cable remote controls due to reports of unintended movement during surgical cases.

    Product
    Cable remote control JUPITER, Material no. 4544119, Serial number: to (incl.) 102284378. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0918-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER U Cable Remote Controls

    Trumpf Medical Systems is recalling 137 JUPITER U cable remote controls due to reports of unintended movement during surgical cases.

    Product
    Cable remote control JUPITER U, Material no.4500119, Serial number: to (incl.) 102306915. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0909-2015·2015-01-14

    Ebi Recalls Cypher MIS Screw System Due to Inoperative Screw Heads

    Ebi, LLC is recalling the Cypher MIS Screw System because screw heads may splay or fracture, rendering the device inoperative.

    Product
    Cypher MIS Screw System-The system includes screws, various types and sizes of rods, and set screws. Various instruments are also available for use by the surgeon to facilitate implantation of the device. Non-cervical spinal fixation device intended for immobilization and…
    Category
    Medical Device
    Distribution
    9 states
  • HighFDA (Devices)·Z-0929-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Remote Controls for Unintended Movement

    Trumpf Medical Systems is recalling JUPITER remote controls due to reports of unintended movement during surgical cases caused by damaged units.

    Product
    IR remote control JUC, BUTTON, Material no.1239824, Serial number: to (incl.) 100139854. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0914-2015·2015-01-14

    Siemens e.cam Systems Recalled for Potential Patient Finger Injury

    Siemens Medical Solutions is recalling 4,462 e.cam emission computed tomography systems due to a potential risk of patient finger injury.

    Product
    e.cam -emission computed tomography system Used to detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588keV.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0933-2015·2015-01-14

    KCI CelluTome Epidermal Harvesting System Harvester Blades May Drift During Shipping

    KCI USA is recalling CelluTome Epidermal Harvesting System Harvesters because blades may drift and protrude from the top plate during shipping.

    Product
    CelluTome Epidermal Harvesting System Harvester (5.0 CM) STERILE EO Rx Only Manufactured for: KCI USA, Inc. Part Number CT-H50 or CT-H25 The CelluTome Epidermal Harvesting System is intended to reproducibly cut a thin skin graft for autologous skin grafting.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0942-2015·2015-01-14

    Centurion Chest Tube Tray Recalled Due to Human Hair Contamination

    Centurion Medical Products is recalling 42 Chest Tube Tray kits because a single unit was found to contain human hair embedded in the stopper.

    Product
    Chest Tube Tray (Cardiovascular Surgical Instruments convenience kit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0911-2015·2015-01-14

    Siemens Symbia S Series Medical Imaging Systems Recalled for Detector Motion

    Siemens is recalling 877 Symbia S series imaging systems due to reports of unintended detector motion that may cause patient compression injuries.

    Product
    The Siemens Symbia S series is intended for use by appropriately trained health care professionals to aid in detecting, localizing, diagnosing, staging and restaging of lesions, tumors, disease and organ function for the evaluation of diseases and disorders such as, but not…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0912-2015·2015-01-14

    Siemens Symbia T Series SPECT/CT Systems Recalled for Detector Motion

    Siemens Medical Solutions USA is recalling 1,330 Symbia T series SPECT/CT systems worldwide due to reports of unintended radial detector motion that may cause patient compression injuries.

    Product
    The Siemens Symbia T series is intended for use by appropriately trained health care professionals to aid in detecting, localizing, diagnosing, staging and restaging of lesions, tumors, disease and organ function for the evaluation of diseases and disorders such as, but not…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0945-2015·2015-01-14

    Centurion Pacemaker Tray Recalled Due to Human Hair Contamination

    Centurion Medical Products is recalling 8 pacemaker trays because a customer reported human hair embedded in the stopper of a single unit.

    Product
    Pacemaker Tray (Cardiovascular Surgical Instruments convenience kit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0940-2015·2015-01-14

    Intuitive Surgical Recalls da Vinci Si Vision Side Carts Due to Wheel Loosening

    Intuitive Surgical is voluntarily correcting 202 da Vinci Si Vision Side Carts where caster wheel bolts may unthread, causing wheels to loosen.

    Product
    IS3000 Vision Side Cart (VSC) used in conjunction with the da Vinci Si Surgical System IS3000. Product number 371683-05/Model Number VS3000 The Intuitive Surgical Endoscopic Instrument Control System (Intuitive Surgical da Vinci Surgical System Model IS3000) is intended to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0925-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Remote Controls for Unintended Movement

    Trumpf Medical Systems is recalling JUPITER remote controls used with operating tables due to reports of unintended movement during surgical cases.

    Product
    (R)Cable remote control JUPITER, Material no.1219655, Serial number: to (incl.) 101998119. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0927-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Operating Table Remote Controls

    Trumpf Medical Systems is recalling JUPITER operating table remote controls because damaged units may cause unintended movement during surgery.

    Product
    IR remote control JUX, Material no.1307314, Serial number: to (incl.) 102338310 Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer system to…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0919-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Operating Table Remote Controls

    Trumpf Medical Systems is recalling JUPITER operating table remote controls because damaged units may cause unintended movement during surgery.

    Product
    Cable remote control JUPITER / TS7500, Material no.1601926, Serial number: to (incl.) 101465919. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0928-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Operating Table Remote Controls

    Trumpf Medical Systems is recalling JUPITER operating table remote controls due to reports of unintended movement during surgical cases.

    Product
    Cable remote control JUC, BUTTON, Material no.1239823, Serial number: to (incl.) 100143048. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient…
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-0902-2015·2015-01-14

    Horiba Medical Recalls ABX PENTRA Reagent Containers for Fit Issues

    Horiba Medical is recalling ABX PENTRA Reagent Containers because they may not sit properly in the rack, potentially causing incorrect test results without an alarm.

    Product
    ABX PENTRA Reagent Container, Model No. B1037307 (15 mL), B1034626 (10 mL), and B1034634 (4 mL)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0934-2015·2015-01-14

    Vision RT AlignRT 3D Imaging System Recalled for Potential Use Error

    Vision RT Inc. is recalling 55 AlignRT 3D surface imaging systems due to a potential use error when the external Gate Controller is turned on after software startup.

    Product
    AlignRT is a video-based three-dimensional (3D) surface imaging system which is used to image the skin surface of a patient in 3D before and during radiotherapy treatment.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0913-2015·2015-01-14

    Siemens Symbia Intevo SPECT CT Systems Recalled for Detector Motion

    Siemens is recalling six Symbia Intevo SPECT CT systems worldwide because unintended detector motion may cause patient compression injuries.

    Product
    The Symbia Intevo Excel is a non-diagnostic SPECT ICT system with CT support for only attenuation correction and anatomical localization. The Symbia Intevo Series are xSPECT systems. These are SPECT and T systems integrated through xSPECT technology during image registration…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0926-2015·2015-01-14

    Trumpf Medical Systems Recalls JUPITER Operating Table Remote Controls

    Trumpf Medical Systems is recalling JUPITER operating table remote controls due to reports of unintended movement during surgical cases.

    Product
    Cable remote control JUX Material, no.1307315, Serial number: to (incl.) 101287649. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient transfer system…
    Category
    Medical Device
    Distribution
    25 states
  • ModerateFDA (Devices)·Z-0944-2015·2015-01-14

    Centurion Diagnostic Imaging Tray Recalled for Human Hair Particulate

    Centurion Medical Products is recalling 760 Diagnostic Imaging Trays due to a confirmed report of human hair embedded in a stopper.

    Product
    Diagnostic Imaging Tray (General Surgery convenience kit)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0939-2015·2015-01-14

    Baxter HomeChoice Automated Peritoneal Dialysis Systems Recalled for Updated Warnings

    Baxter Healthcare is recalling HomeChoice and HomeChoice Pro Automated Peritoneal Dialysis systems because the patient guide lacks updated warnings and cautions.

    Product
    HomeChoice Automated PD system and HomeChoice Pro Automated PD system Baxter's HomeChoice and HomeChoice Pro APD systems are designed to provide Automated Peritoneal Dialysis (APD) therapy for pediatric and adult renal patients. Their Fill volumes can range from 60 mL to 3000…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0906-2015·2015-01-14

    Exactech Recalls Mislabeled Optetrak Femoral Implants

    Exactech, Inc. is voluntarily recalling 96 Optetrak femoral implants due to mislabeling. The devices were distributed internationally to 13 countries.

    Product
    Optetrak Asymmetric Hi-Flex Posterior Stabilized Cemented Femorals, size 3, Catalog #244-02-03, Catalog #244-03-03. Usage:Femoral implants
    Category
    Medical Device
    Distribution
    0 states

Looking for a different category? Browse all recalls.