Trumpf Medical Systems Recalls JUPITER Operating Table Remote Controls
Trumpf Medical Systems is recalling JUPITER operating table remote controls due to reports of unintended movement during surgical cases.
The agency’s classification
FDA (Devices): Class II
Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.
This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work
What this means for you
Our assessment, not the agency’s: severity 3/5 (High).
Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.
Our severity reasoning: The recall involves a risk-of-harm product (unintended movement during surgery) where injury has not yet been reported, meeting the criteria for a High severity score.
Plain-English summary
Trumpf Medical Systems, Inc. is recalling 3,303 JUPITER operating table remote controls (Material no. 1239823, serial numbers up to and including 100143048). The recall is being conducted because complaints have been reported of unintended movement occurring during surgical cases due to the use of damaged remotes.
The affected remote controls are used for patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery, as well as for patient transport on the operating tabletop. The devices are distributed worldwide, including in the United States and Canada.
Healthcare facilities should stop using the affected remote controls and contact Trumpf Medical Systems for further instructions on the recall.
The recalled product
- Product
- Cable remote control JUC, BUTTON, Material no.1239823, Serial number: to (incl.) 100143048. Patient positioning during surgery, ranging from anesthesia induction to actual surgery to recovery from anesthesia. Patient transport on the operating tabletop, from the patient…
- Manufacturer
- Trumpf Medical Systems, Inc.
- Category
- Medical Device — Operating Table
- Hazard
- Affected units
- 3,303
Is your product affected?
Check your packaging against the codes below. If any of them match, the product is part of this recall.
Lot numbers (17)
- Material no. 4500113
- Mobile column JUPITER System Miyabi U
- Material no. 1574977
- Operating table column JUPITER SM 360 U
- Material no. 1389824
- Operating table column JUPITER SF U OCE
- Material no. 1622774
- Stationary column JUPITER System U
- Material no. 4500112
- FLOOR MOUNTING COLUMN JUPITER U
- Material no. 1276277
- Floor mounting column JUPITER 360 U
- Material no.1389826
- Operating table JUPITER UNIVERSAL U
- Material no. 4500170
- OR-TABLE JUPITER UNIVERSAL CARBON U
- Material no.1223188.
Distribution
Part of a larger recall action
This product is one of 12 recalled by Trumpf Medical Systems, Inc. under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.
See all 12 products in this recall →Related recalls
Same manufacturer · Trumpf Medical Systems, Inc.
See all →- ModerateTrumpf Medical Systems Recalls Surgical Camera Systems Due to Emission Issues
FDA (Devices) · 2018-03-07
- HighTrumpf Medical Systems Recalls Operating Room Table Tops for Cable Pinching
FDA (Devices) · 2016-11-16
- HighTrumpf Medical Systems Recalls Floor Mounting Columns for Unexpected Descent
FDA (Devices) · 2016-10-12
- HighTrumpf Medical Systems Recalls Stationary Column TruSystem 7599 Operating Tables
FDA (Devices) · 2016-10-12
- HighTrumpf Medical Systems Recalls TruSystem Operating Tables Due to Unexpected Descent
FDA (Devices) · 2016-10-12
Same hazard · unintended movement
See all →- SevereKoenigsegg Recalls CC850 Vehicles Due to Electronic Parking Brake Defect
NHTSA · 2026-10-21
- HighGreenpower Recalls EV Star Buses Due to Software Error
NHTSA · 2026-09-30
- HighMedos Velys Robotic-Assist Station Recalled for Software Movement Issue
FDA (Devices) · 2026-09-09
- HighATC Recalls 2026 RM500 and RM700 Trailers Due to Winch Remote Issue
NHTSA · 2026-07-22
- HighWarn Industries Recalls Wireless Remote Kits Due to Winch Movement Risk
NHTSA · 2026-07-02
Similar recalls
- HighTrumpf TITAN Operating Room Table Recalled for Unintended Movement
FDA (Devices) · 2014-11-05
- HighTrumpf Medical Systems Recalls TruSystem Operating Tables Due to Unexpected Descent
FDA (Devices) · 2016-10-12
- SevereTrumpf Medical Systems Recalls TruSystem Mobile Operating Columns
FDA (Devices) · 2016-10-12
- HighTrumpf Medical Systems Recalls Stationary Column TruSystem 7599 Operating Tables
FDA (Devices) · 2016-10-12
- HighTrumpf Medical Systems Recalls Patient Transport Shuttles Due to Tilting Hazard
FDA (Devices) · 2016-02-17
- ModerateTrumpf Medical Systems Recalls ORBIT PT Patient Transport Device
FDA (Devices) · 2013-11-13