Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

33501–33525 of 40489

  • HighFDA (Devices)·Z-1250-2015·2015-03-18

    Pivotal Health Solutions Recalls Apollo Laser Desktop Control Units

    Pivotal Health Solutions is recalling 35 Apollo Laser Desktop Control Units because internal mounting kits do not meet safety standards, increasing the risk of electric shock.

    Product
    Apollo (cold) Laser Desktop Control Units, Model AP2-DT. The Apollo IR Heat Lamp System is intended to emit energy in the infrared spectrum to provide topical heating for the purpose of elevating tissue temperature for the temporary relief of minor muscle and joint pain and…
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-1267-2015·2015-03-18

    Siemens CT System Recalled for Image Artifacts and Safety Issues

    Siemens Medical Solutions is recalling 12 SOMATOM Force CT systems due to potential image artifacts and safety-related software issues.

    Product
    SIEMENS SOMATOM Force with software version VA50A and /or VA50A_FP1 and/or VA50A_SP0; Computed tomography system. Product Usage: The intended use of computed tomography is to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1258-2015·2015-03-18

    Siemens Healthcare Recalls Capillary Caps Due to Breakage Risk

    Siemens Healthcare is recalling capillary caps that may fail to attach, causing glass capillaries to break.

    Product
    Siemens Healthcare Caps for capillary 50/60 uL, Package count 200 For use with blood collection Multicap glass and Multicap-S plastic capillaries SMN: 10328655 Legacy Part number: 478527
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1260-2015·2015-03-18

    Synthes Inserter for Titanium Elastic Nails Recalled for Mechanical Failure

    Synthes, Inc. is recalling Inserter for Titanium Elastic Nails due to potential mechanical failures including shaft breakage and chuck malfunction.

    Product
    Synthes Inserter for Titanium Elastic Nails; The Inserter for Titanium Elastic Nails (TEN) is intended for fixation of diaphyseal fractures where the canal is narrow or flexibility of the implant is paramount. This includes: lower extremity fractures in pediatric and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1261-2015·2015-03-18

    Dako Automated Slide Stainers Recalled for Potential Diagnostic Errors

    Dako North America Inc. is recalling four models of automated slide stainers because a defect may cause buffer leakage, leading to false negative diagnostic results.

    Product
    Autostainer Link 48 (AS480), Autostainer Plus Link Instrument (AS100), Autostainer (S3400), and Autostainer Plus (S3800). Automated slide stainer for in vitro diagnostic use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1257-2015·2015-03-18

    Siemens Healthcare Recalls Capillary Caps Due to Breakage Risk

    Siemens Healthcare is recalling capillary caps that may fail to attach, causing glass capillaries to break.

    Product
    Siemens Healthcare Caps for capillary 140/175 uL, Package count 100 For use with blood collection Multicap glass and Multicap-S plastic capillaries SMN: 10311054 Legacy Part number: 478605
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1079-2015·2015-03-18

    Villa Radiology Juno DFR X-ray System Recalled for Control Defects

    Villa Radiology Systems LLC is recalling 30 Juno DFR X-ray systems because they lack required audible signals, permanent activation, and manual override features.

    Product
    Juno DFR X-ray system
    Category
    Medical Device
    Distribution
    21 states
  • HighFDA (Devices)·Z-1266-2015·2015-03-18

    Zimmer Persona Trabecular Metal Tibial Plate Recall for Loosening Complaints

    Zimmer, Inc. is recalling Persona Trabecular Metal Tibial Plates due to increased complaints of loosening and radiolucent lines.

    Product
    Persona Trabecular Metal Tibial Plate / Persona TM Tibia-Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer For use in either posterior cruciate retaining or sacrificing surgical procedures.
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1262-2015·2015-03-18

    Medela Recalls Sterile Enteral Feeding Syringes Due to Packaging Breach

    Medela Inc. is recalling sterile enteral feeding syringes because a potential packaging breach may have compromised their sterility.

    Product
    - NTL-30 30ml Nutrio Enteral Feeding Syringe (sterile) - NTL-60 60ml Nutrio Enteral Feeding Syringe (sterile) - TL-INT-60 60ml Nutrio Enteral Feeding Syringe with Twistlok adapter (sterile) - INT-60 60mL Nutrio Intopo Enteral Feeding Syringe (sterile) - NGF-60 60ml Nutrio…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1259-2015·2015-03-18

    Arrow Intra-Aortic Balloon Catheter Kit Recalled for Potential Helium Leak

    Arrow International Inc is recalling 166 units of Intra-Aortic Balloon Catheter Kits due to a potential leak that allows helium to escape.

    Product
    Arrow Intra-Aortic Balloon Catheter Kit Fiberoptix (IAB), 8 Fr 40 cc Model: IAB-05840-LWS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1252-2015·2015-03-18

    Siemens RAPIDPoint 405 Blood Gas Analyzer Recalled for Neonatal Bilirubin Variability

    Siemens is recalling 3,420 RAPIDPoint 405 Blood Gas Analyzers worldwide because the neonatal bilirubin parameter may show increased variability under specific high-concentration conditions.

    Product
    RAPIDPoint 405 Blood Gas Analyzer; Siemens Material Number: 10310464, 10322347, 10314817, 10317193, 10318999, 10320055, 10322347, 10328278, 10328302, 10336784. These systems are intended for near-patient and laboratory testing of blood gases, electrolytes, metabolites, total…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1265-2015·2015-03-18

    Southern Implants Recalls Dental Implants Due to Labeling Mismatch

    Southern Implants, Inc. is recalling 130 units of MAX-TL and Z-MAX dental implants because the labeled packages contained the wrong implant type.

    Product
    MAX-TL 9.0 x 7.0 mm Implant, Catalog No. 15711K; Z-MAX Implant 9.0 x 7 mm Length, Catalog No. Z-MAX9-7. Dental implant. Product Usage: The MAX Implant is intended to be implanted in the upper and lower jaw arches to provide support for fixed or removable dental prostheses…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1255-2015·2015-03-18

    Siemens RAPIDLab 1265 System Recalled for Neonatal Bilirubin Variability

    Siemens Healthcare Diagnostics Inc is recalling 2,863 RAPIDLab 1265 Systems because the neonatal bilirubin parameter may show increased variability under specific high-concentration conditions.

    Product
    RAPIDLab 1265 System; Siemens Material Number: 10491395, 10321852, 10335524. The Rapidlab 1200 systems are intended for in vitro diagnostic use by healthcare professionals in the quantitative testing of human whole blood. The systems can determine the following parameters…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1253-2015·2015-03-18

    Siemens RAPIDPoint 500 Blood Gas Analyzer Recalled for Neonatal Bilirubin Variability

    Siemens is recalling 4,376 RAPIDPoint 500 Blood Gas Analyzers worldwide because the neonatal bilirubin parameter may show increased variability under specific high-concentration conditions.

    Product
    RAPIDPoint 500 Blood Gas Analyzer; Siemens Material Number: 10492730, 10696855, 10696857, 10697306. The RAPIDPoint 500 system is designed for professional use in a point-of-care or laboratory environment. This system tests blood gases, electrolytes, metabolites, total…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1254-2015·2015-03-18

    Siemens RapidLab 1245 System Recalled for Neonatal Bilirubin Variability

    Siemens is recalling 241 RapidLab 1245 systems because the neonatal bilirubin parameter may show increased variability under specific high-concentration conditions.

    Product
    RAPIDLab 1245 System; Siemens Material Number: 10321844, 10491393, 10337179. The Rapidlab 1200 systems are intended for in vitro diagnostic use by healthcare professionals in the quantitative testing of human whole blood. The systems can determine the following parameters…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1263-2015·2015-03-18

    Ortho-Clinical VITROS Hand-held Barcode Scanner Recall for Sample Skipping

    Ortho-Clinical Diagnostics is recalling VITROS Hand-held Barcode Scanners because they may skip sample cup positions when using the Batch Programming option.

    Product
    VITROS Hand-held Barcode Scanner, Catalog Number 6844210, for use with the following VITROS Systems: VITROS 5,1 FS Chemistry System, VITROS 3600 Immunodiagnostics System, VITROS 4600 Chemistry System, VITROS 5600 Integrated System. This product is an accessory for use with…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1264-2015·2015-03-18

    Richard-Allan Scientific Recalls Mislabelled CYTO-STAIN R Stain Bottles

    Richard-Allan Scientific is recalling 132 gallons of CYTO-STAIN R Stain because the bottles were incorrectly labeled as CYTO-STAIN G, although the contents are correct.

    Product
    Carton: Richard-Allan Scientific CYTO-STAIN; REF 7501R; Quantity: 1x1 Gallon; Size: 1 Gallon/3.8L; LOT 313833; 11/2016; Bottle: Richard-Allan Scientific CYTO-STAIN G; REF 7501G; 1 Gallon/3.8L; Thermo Scientific.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1240-2015·2015-03-11

    Richard Wolf I-Cart Medical Video Equipment Recall for Overheating Transformers

    Richard Wolf Medical Instruments Corp. is recalling 83 I-Cart units because transformers may overheat, causing smoke and black plastic material to leak from the chassis.

    Product
    The I-Cart is used to store, transport, and power video equipment used in medical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1209-2015·2015-03-11

    Boston Scientific Recalls IntellaTip MiFi Radiofrequency Ablation Catheters

    Boston Scientific is recalling 14 IntellaTip MiFi radiofrequency ablation catheters due to reports of char formation on the distal tip electrodes.

    Product
    IntellaTip MiFi Open-Irrigated radiofrequency Ablation Catheters: Material number: M004EPM96200, Catalog Number: EPM9620: Material number: M004EPM9620K20, Catalog Number: EPM9620K2; Material number : M004EPM9620N40; Catalog number: EPM9620N4. The IntellaTip MiFi…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1242-2015·2015-03-11

    Biosense Webster Recalls LASSO NAV Duo Loop eco Catheters

    Biosense Webster is recalling LASSO NAV Duo Loop eco Catheters due to reports of difficulty retracting and damage to the spine cover.

    Product
    LASSO NAV Duo Loop eco Catheters, Catalog No. D-1354-01, D-1354-02, D-1354-03, D-1354-04, D-1354-05, D-1354-06. LASSO NAV DUO LOOP eco Catheter is indicated for multiple electrode electrophysiological mapping of the cardiac structures of the heart, i.e. recording or stimulation…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1234-2015·2015-03-11

    Zipline Medical Recalls Zip 8i Surgical Skin Closure Devices

    Zipline Medical is recalling Zip 8i Surgical Skin Closure Devices because the manufacturer's seal may be missing, compromising sterility assurance.

    Product
    Zip 8i Surgical Skin Closure Device; for incisions up to 8 cm. Product number PS2080 Indicated for use during and after skin incision procedures to approximate skin and hold together skin edges until healing can take place.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1120-2015·2015-03-11

    Philips Allura Xper X-Ray Angiographic Software Recall

    Philips Medical Systems is recalling Allura Xper X-Ray Angiographic systems due to a software error that may prevent the five-minute fluoroscopy audible signal from sounding.

    Product
    Philips Medical System Allura Xper X-Ray Angiographic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1236-2015·2015-03-11

    Zipline Medical Recalls Zip 16 Surgical Skin Closure Devices

    Zipline Medical is recalling Zip 16 Surgical Skin Closure Devices because the manufacturer's seal may be missing, compromising sterility assurance.

    Product
    Zip 16 Surgical Skin Closure Device; 16 cm Product number PS1160; Rx only, Sterile Indicated for use during and after skin incision procedures to approximate skin and hold together skin edges until healing can take place.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1243-2015·2015-03-11

    iCAD Recalls DynaLOC Breast Interventional Planning Software Versions 3.1 and 3.2

    iCAD, Inc. is recalling DynaLOC Breast Interventional Planning Software Versions 3.1 and 3.2 because a device malfunction may cause biopsy needles to miss targets, potentially leading to incorrect diagnoses.

    Product
    DynaLOC Breast Interventional Planning Software Versions 3.1 and 3.2
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1224-2015·2015-03-11

    Maquet Servo-I Ventilator CO2 Analyzer Recalled for Calibration Defect

    Maquet is recalling 486 Servo-I ventilator CO2 analyzers worldwide due to a calibration problem caused by an internal circuit board defect.

    Product
    Servo-I ventilator system CO2 analyzer. Part number 65 23 588.
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.