Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

33526–33550 of 40489

  • HighFDA (Devices)·Z-1235-2015·2015-03-11

    Zipline Medical Recalls Zip 8M Wound Closure Devices Due to Sterility Concerns

    Zipline Medical is recalling Zip 8M Wound Closure Devices because the manufacturer's seal may be missing, compromising sterility assurance.

    Product
    Zip 8M Wound Closure Device; for wounds up to 8 cm in length; Product number PS9080; Rx only, Sterile Indicated for use during and after skin incision procedures to approximate skin and hold together skin edges until healing can take place.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1220-2015·2015-03-11

    Halyard Health Recalls KimVent Closed Suction Systems Due to Defects

    Halyard Health is recalling KimVent Closed Suction Systems for Adults because a hole or crack was found that may cause air to leak.

    Product
    KimVent Closed Suction System for Adults, Double Swivel Elbow, 12 Fr., Sterile, Distributed by Kimberly Clark Global Systems, LLC.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1221-2015·2015-03-11

    Halyard Health Recalls KimVent Closed Suction Systems Due to Air Leak Defect

    Halyard Health is recalling KimVent Closed Suction Systems for Adults because a hole or crack may cause air to leak. The recall affects 5 cases distributed to specific US states and Japan.

    Product
    KimVent Closed Suction System for Adults, Double Swivel Elbow, 14 Fr. Sterile, Distributed by Kimberly Clark Global Systems, LLC.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1237-2015·2015-03-11

    Elekta Monaco Radiation Therapy System Recalled for Incorrect CT to ED Conversion

    Elekta, Inc. is recalling Monaco radiation therapy treatment planning systems because the Image Statistics Tool may incorrectly convert CT to ED values.

    Product
    Monaco radiation therapy treatment planning system. The Monaco system is used to make treatment plans for patients with prescriptions for external beam radiation therapy. The system calculates dose for photon and electron treatment plans and displays, on-screen and in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1222-2015·2015-03-11

    Halyard Health Recalls KimVent Wet Pak Closed Suction Systems

    Halyard Health is recalling KimVent Wet Pak closed suction systems because a defect may cause air leaks.

    Product
    KimVent Wet Pak, Closed Suction System for Adults, Double Swivel Elbow, 14 Fr. Sterile, Distributed by Kimberly Clark Global Systems, LLC.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1244-2015·2015-03-11

    Elekta Focal Sim radiation therapy system recalled for image statistics error

    Elekta, Inc. is recalling 907 Focal Sim radiation therapy treatment planning systems because the Monaco Image Statistics Tool may produce incorrect CT to ED values.

    Product
    Focal Sim radiation therapy treatment planning system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1230-2015·2015-03-11

    Siemens ADVIA Centaur Progesterone Kit Recalled for High Bias in Results

    Siemens is recalling ADVIA Centaur Systems Progesterone Kits because results above 30 ng/mL show high bias. The recall covers 11,980 kits distributed worldwide.

    Product
    ADVIA Centaur Systems Progesterone Kit, (5 -pack); In Vitro Diagnostic; Catalog number: 01586287; SMN:10315522.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1210-2015·2015-03-11

    Xoran MiniCAT X-ray devices recalled for imaging and dose defects

    Xoran Technologies is recalling 432 MiniCAT X-ray imaging devices nationwide due to out-of-tolerance kVp, unexposed frames, and out-of-tolerance dose.

    Product
    Xoran MiniCAT X-ray imaging device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1223-2015·2015-03-11

    Ikaria INOmax DSIR Nitric Oxide Delivery System Recalled for Alarm Defect

    INO Therapeutics is recalling 45 INOmax DSIR units because a specific software and display combination may trigger false alarms, interrupting nitric oxide therapy.

    Product
    Ikaria, INOmax DSIR (Delivery System), Model 10007. Nitric oxide delivery system for use with ventilators.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1216-2015·2015-03-11

    Arjo RotoRest Delta Therapy System Recalled for Unapproved Medical Claims

    Arjo Hospital Equipment AB is recalling 271 RotoRest Delta Advanced Therapy Systems because their labeling contains unapproved medical claims.

    Product
    RotoRest Delta Advanced Therapy System. The RotoRest Delta Advanced Kinetic Therapy System offers kinetic therapy for the most aggressive treatment of pulmonary complications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1218-2015·2015-03-11

    Arjo TriaDyne Proventa Critical Care Therapy System Recalled for Unapproved Claims

    Arjo Hospital Equipment AB is recalling 567 TriaDyne Proventa Critical Care Therapy Systems because their labeling and instructions for use contain unapproved medical claims.

    Product
    TriaDyne Proventa Critical Care Therapy System. The TriaDyne Proventa Critical Care Therapy System provides a comprehensive system of pulmonary and skin care therapies for the critically ill, immobilized patient.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1246-2015·2015-03-11

    DePuy Orthopaedics Recalls Partially Agglomerated SMARTSET GHV Bone Cement

    DePuy Orthopaedics is recalling one lot of SMARTSET GHV Gentamicin Bone Cement because it is partially agglomerated, which may cause surgical delays.

    Product
    SMARTSET GHV Gentamicin Bone Cement. A self-curing, radiopaque, polymethyl methacrylate based cement containing antibiotic. It is used for securing a metal or polymeric prosthesis to living bone in arthroplasty procedures. The bone cement has no intrinsic adhesive properties…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1227-2015·2015-03-11

    Baxter Recalls Syringe Tip Caps for Missing Latex Symbol

    Baxter is recalling Self-Righting Syringe Tip Caps because the latex symbol is missing from the labels.

    Product
    Baxter, Self-Righting Syringe Tip Caps, Self-Righting DISCPAC Syringe Tip Caps. Product codes H93866100, H93869100, H93866025, H93867025, H93867100, H938671025, H938671100, H938673025, H938673100, H938674025, H938674100, H938676025, H938676100, H938677025, H938677100…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1241-2015·2015-03-11

    Stryker Recalls V40 Femoral Heads Due to Assembly Issues

    Stryker Howmedica Osteonics is recalling nine V40 femoral heads because they could not be assembled with their corresponding stem trunnions.

    Product
    LFT v40 Femoral Head; Catalog Number 6260-9-032; V40 CoCr LFit Head 32mm/-4. Designed to be assembled onto a femoral hip stem trunnion during surgery for a total hip arthroplasty.
    Category
    Medical Device
    Distribution
    5 states
  • ModerateFDA (Devices)·Z-1217-2015·2015-03-11

    Arjo Rotoprone Therapy System Recalled for Unapproved Medical Claims

    Arjo Hospital Equipment AB is recalling 226 Rotoprone Therapy Systems because their labeling and instructions for use contain unapproved medical claims.

    Product
    Rotoprone Therapy System. The Rotoprone Therapy System is an advanced patient care system for the treatment and prevention of pulmonary complications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1231-2015·2015-03-11

    Siemens ADVIA Centaur Progesterone Kit Recalled for High Result Bias

    Siemens is recalling ADVIA Centaur Progesterone Kits due to high bias in results above 30 ng/mL. The recall affects 1,719 kits distributed worldwide.

    Product
    ADVIA Centaur Systems Progesterone Kit, (5-pack Ref); In Vitro Diagnostic Catalog number: 02177364; SMN: 10333111.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1229-2015·2015-03-11

    Siemens ADVIA Centaur Progesterone Kit Recall for High Bias in Results

    Siemens Healthcare Diagnostics is recalling ADVIA Centaur Systems Progesterone Kits because results above 30 ng/mL may show high bias.

    Product
    ADVIA Centaur Systems Progesterone Kit, (1 -pack) In Vitro Diagnostic; Catalog number: 02382928; SMN: 10310305.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1245-2015·2015-03-11

    Baxter AMIA v1.0 APD System Recall for Labeling Warning

    Baxter Healthcare is recalling 55 AMIA v1.0 APD Systems to add a warning about the risk of unintended increased intraperitoneal volume for vulnerable patients.

    Product
    AMIA v1.0 APD System. For Automated Peritoneal Dialysis (APD) therapy for pediatric and adult renal patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1226-2015·2015-03-11

    Intuitive Surgical Recalls Vacuum Source Tubing Sets for Sterility Concerns

    Intuitive Surgical is recalling 706 Vacuum Source Tubing Sets for the EndoWrist Stabilizer because shipping damage may have compromised the sterile packaging.

    Product
    Vacuum Source Tubing Set for the EndoWrist Stabilizer for da Vinci S (IS2000) and Si (IS3000); Part number 420187-05. The Intuitive Surgical EndoWrist Stabilizer Instrument is intended to be used with the fourth arm of the da Vinci S Surgical System. The Intuitive Surgical…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1232-2015·2015-03-11

    Remel Recalls Oxoid Legionella BCYE Growth Supplement Due to False Negatives

    Remel Inc is recalling Oxoid Legionella BCYE Growth Supplement SR0110A because it may fail to recover Legionella pneumophila, leading to false negative test results.

    Product
    Oxoid Legionella BCYE Growth Supplement SR0110A packaged in packs of 10- 100 ml vials. The responsible firm name on the label is Oxoid Ltd., Basingstoke, Hampshire, England and Oxoid Ltd., Basingstoke, Hants, England.
    Category
    Medical Device
    Distribution
    5 states
  • ModerateFDA (Devices)·Z-1219-2015·2015-03-11

    Zimmer Segmental System Hip Stem Recalled for Coating Defect

    Zimmer, Inc. is recalling specific Zimmer Segmental System hip stems because the PMMA coating may be missing or not meet specifications.

    Product
    Zimmer Segmental System (ZSS) Cemented Stem / ZSS Cemented Stem, Smooth Stem Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented or Non-Porous, Uncemented.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1239-2015·2015-03-11

    CooperSurgical Pessary Kit Recalled for Incorrect Size Labeling

    CooperSurgical is recalling 95 units of Pessary Kit-CUBE#2 because the packaging label displays the incorrect size.

    Product
    CooperSurgical PESSARY KIT-CUBE#2, 1-3/8 in , 35 mm Part Number: MXKPEC02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1233-2015·2015-03-11

    Arrow FiberOptix Intra-Aortic Balloon Catheter Kit Recalled for Labeling Error

    Arrow International Inc. is recalling 165 units of FiberOptix Intra-Aortic Balloon Catheter Kits because the outer package label incorrectly identifies the product size.

    Product
    ARROW FiberOptix Intra-Aortic Balloon Catheter Kit, 40 cc 7.5 Fr Product Code: IAB-05840-LWS The Arrow IAB is utilized for intra-aortic balloon counter-pulsation therapy in the aorta, whereby balloon inflation, during diastole and deflation, during systole increases blood…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1228-2015·2015-03-11

    Medtronic CareLink Pro Software Recall for Inaccurate Basal Data Display

    Medtronic MiniMed is recalling CareLink Pro and CareLink Clinical software due to a defect that may cause inaccurate display of Temp Basal time and duration in reports.

    Product
    CareLink Pro Medtronic CareLink Pro MMT-7335 is a personal computer software application designed to enhance Health Care Provider management of diabetic patients using Medtronic insulin pumps and blood glucose meters. MMT-7335 is intended for use by Health Care…
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1137-2015·2015-03-04

    Invacare TDX Electric Wheelchairs Recalled for Fire Hazard

    Invacare is recalling 1,942 TDX, FDX, and Storm Series power wheelchairs because wire pinching can cause smoking, sparking, or fire.

    Product
    TDX Electric Wheelchair. Invacare FDX, TDX series and Storm Series (3G) power wheelchairs in 20 to 24 inch width configurations with power recline seating system and a conventional style back.
    Category
    Medical Device
    Distribution
    Distributed nationwide