The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

29601–29625 of 40489

  • LowFDA (Devices)·Z-2378-2016·2016-08-17

    BD Tritest CD3/CD4/CD45 Reagent Recalled for Incorrect Labeling

    Becton, Dickinson and Company is recalling 14,089 vials of BD Tritest CD3 FITC/CD4 PE/CD45 PerCP because the label incorrectly states the product contains gelatin.

    Product
    BD Tritest CD3 FITC/CD4 PE/CD45 PerCP (IVD); Catalog number 340383. Label states: Contains CD3 FITC/CD4 PE/CD45 per CP with Gelatin and 0.1% sodium azide. Hematology: BD Tritest CD3 fluorescein isothiocyanate (FITC)/CD4 phycoerythrin (PE)/CD45 peridinin chlorophyll…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2345-2016·2016-08-17

    Medivance ArcticGel Neonatal Pad Recalled for Missing Multilingual Instructions

    C.R. Bard is recalling 64 Medivance ArcticGel Neonatal Pads because the included instructions were missing required languages for CE-marked products.

    Product
    Medivance ArcticGel Neonatal Pad The pad is designed to fit into an incubator and provide whole body cooling for patients.
    Category
    Medical Device
    Distribution
    13 states
  • SevereFDA (Devices)·Z-2339-2016·2016-08-10

    Zimmer Air Dermatome II Width Plate Recalled for Surface Coating Defects

    Zimmer Surgical Inc is recalling 90 units of Air Dermatome II Width Plates because the surface coating is blistering, peeling, and discoloring after use.

    Product
    Zimmer¿ Air Dermatome II Width Plate, 3 inch. Part #00-8851-203-00. Width plate is packaged inside of a padded-foam corrugate box. A product label is applied to the lid of the box. The width plates, when sold individually, are placed in a labeled poly zipper bag, which is then…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2215-2016·2016-08-10

    Draeger Recalls Oxylog 3000 Pediatric Patient Circuits Due to Leakage

    Draeger Medical is recalling Oxylog 3000 disposable pediatric patient circuits because isolated episodes of leakage were found at the check valve.

    Product
    Oxylog 3000, Disposable Pediatric Patient Circuit, Catalog Number: 5704964 The VentStar Oxylog 3000F disposable pediatric patient breathing circuit is used with the Dr¿ger Oxylog 3000 and Oxylog 3000 plus Emergency Transport Ventilators.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2255-2016·2016-08-10

    Olympus Analytical X-Ray Systems Recalled for Trigger Lock Failure

    Olympus Scientific Solutions Americas is recalling Analytical X-Ray Systems because the trigger lock may fail to prevent x-ray generation in test modes.

    Product
    Olympus Scientific Solutions Americas Corporation (OSSA) Model: Analytical X-Ray System X -Ray Fluorescence. Intended to emit ionizing radiation Delta with models: DC-2000, DC-4000, DC-6000, DI-2000, DP-2000, DP-4000, DP-4050, DP- 6000, DPO-4000, DPO-6000, DS-2000…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2341-2016·2016-08-10

    Merge HEMO software recall for inaccurate INR display

    Merge Healthcare is recalling 37 units of Merge HEMO software because the displayed International Normalized Ratio (INR) value does not match the imported value.

    Product
    Merge HEMO software.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2343-2016·2016-08-10

    Spacelabs Ultraview SL Command Module Recalled for NIBP Failure

    Spacelabs Healthcare is recalling Ultraview SL Command Modules because the Non-Invasive Blood Pressure (NIBP) parameter may become non-functional and display error messages.

    Product
    91496 Ultraview SL Command Module, Options A, B, C, and I. Option A: ECG/Respiration, SpO2, Temperature x2 & adult/neonate NIBP. Option B: ECG/Respiration, Invasive Pressure x2, SpO2, Temperature x2 & adult/neonate NIBP. Option C: ECG/Respiration, Invasive Pressure x4…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2305-2016·2016-08-10

    Philips MultiDiagnost Eleva X-Ray System Recalled for Potential Bolt Failure

    Philips is recalling 993 MultiDiagnost Eleva x-ray systems because bolts attaching the clamping plate may break, causing the C-arm to sag.

    Product
    MultiDiagnost Eleva with Flat Detector; x-ray system. Product Codes: 708034, 708037, 708038.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2331-2016·2016-08-10

    Stryker Recalls Spirit Plus Hospital Beds Due to Actuator Failure

    Stryker Medical is voluntarily recalling Spirit Plus hospital beds because broken actuators may cause the bed to lower unexpectedly, risking patient injury.

    Product
    Spirit Plus Bed, A-C Powered Hospital Bed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2324-2016·2016-08-10

    Zimmer Biomet Recalls V-TEK Twist Drills Due to Tolerance Issues

    Zimmer Biomet is voluntarily recalling 169 V-TEK Twist Drills because a potential tolerance stack-up was identified between the drill and the mating Kirschner Wire component.

    Product
    V-TEK TWIST D 40X90MM 30MM Cann 12MM Rnd; The twist drill is used to drill holes into bones/tissues for foot, ankle and hand implant systems.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-2312-2016·2016-08-10

    NeoCoil 3T 16ch Flex SPEEDER Large Coil Recalled for Surface Temperature Risk

    NeoCoil, LLC is recalling 39 units of the 3T 16ch Flex SPEEDER Large Coil due to a potential for higher than specified surface temperatures.

    Product
    3T 16ch Flex SPEEDER Coil, Large, NeoCoil Part Number NC046200, Toshiba Medical Systems Model MJAJ-222A. The NeoCoil 3T 16ch Flex SPEEDER Coils are tuned to receive RF frequency corresponding to the proton precession in a 3 tesla magnetic field, which is governed by the Larmor…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2307-2016·2016-08-10

    Philips MultiDiagnost Eleva X-Ray System Recalled for Bolt Failure Risk

    Philips is recalling 993 MultiDiagnost Eleva x-ray systems because bolts may break, causing the C-arm to sag. The recall covers units distributed worldwide.

    Product
    MultiDiagnost Eleva; x-ray system. Product Codes: 708032, 708036
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2328-2016·2016-08-10

    Philips IntelliVue Patient Monitor Recall for Outdated Waveform Data

    Philips is recalling IntelliVue Patient Monitors because they may display outdated waveform data if powered on continuously for several months, failing to reflect current patient conditions.

    Product
    IntelliVue Patient Monitor Product Usage: The monitors are indicated for use by health care professionals whenever there is a need for monitoring the physiological parameters of patients. The monitors are intended to be used for monitoring and recording of, and to generate…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2321-2016·2016-08-10

    Zimmer Biomet Recalls Twist Drills Due to Tolerance Stack Up

    Zimmer Biomet is voluntarily recalling 169 Twist Drills because a potential tolerance stack up was identified between the drill and the mating Kirschner Wire component.

    Product
    TWIST DR 25X95MM Cann 12MM Thd 30MM AO; The twist drill is used to drill holes into bones/tissues for foot, ankle and hand implant systems.
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-2332-2016·2016-08-10

    Stryker Recalls Spirit Select and Plus Hospital Beds Due to Actuator Failure

    Stryker Medical is voluntarily recalling Spirit Select and Spirit Plus hospital beds because broken actuators may cause the bed to lower unexpectedly, risking patient injury.

    Product
    Spirit Select Bed, A-C Powered Hospital Bed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2308-2016·2016-08-10

    Beckman Coulter Recalls AU480 Chemistry Analyzers Due to Leaking C Cups

    Beckman Coulter is recalling AU480 Chemistry Analyzers because leaking C cups can cause coolant to short-circuit the instrument's circuit boards.

    Product
    AU480 Chemistry Analyzers, Reference No. B28624 The AU series are automated, clinical chemistry analyzers that measure analytes in patient samples (serum, plasma, urine, CSF) in combination with appropriate reagents, calibrators, quality, control (QC) materials, and other…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2310-2016·2016-08-10

    Beckman Coulter AU5800 Chemistry Analyzers Recalled for Leaking C Cups

    Beckman Coulter is recalling AU5800 Chemistry Analyzers because cracked C cups can leak coolant onto circuit boards, causing short-circuits and instrument stop mode.

    Product
    AU5800 Chemistry Analyzers, Reference No. A98352 The AU series are automated, clinical chemistry analyzers that measure analytes in patient samples (serum, plasma, urine, CSF) in combination with appropriate reagents, calibrators, quality, control (QC) materials, and other…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2337-2016·2016-08-10

    Zimmer Air Dermatome II Width Plate Recalled for Surface Coating Defects

    Zimmer Surgical Inc is recalling 90 units of the Air Dermatome II Width Plate because the surface coating is blistering, peeling, and discoloring after use.

    Product
    Zimmer¿ Air Dermatome II Width Plate, 2 inch. Part # 885120200. Width plate is packaged inside of a padded-foam corrugate box. A product label is applied to the lid of the box. The width plates, when sold individually, are placed in a labeled poly zipper bag, which is then…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2330-2016·2016-08-10

    Dako EnVision FLEX+ Mouse High pH Kits Recalled for pH Error

    Dako Denmark A/S is recalling 147 kits of EnVision FLEX+ Mouse, High pH (Link) because the Target Retrieval Solution has an incorrect pH level.

    Product
    EnVision FLEX+, Mouse, High pH (Link), Product No. K8002, K8004. Intended for use in immunohistochemistry together with Autostainer Link Instruments.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2303-2016·2016-08-10

    Merge PACS Software Recall for Annotation Display Defect

    Merge Healthcare is recalling Merge PACS 6.0 software because it fails to display annotations on certain loaded studies.

    Product
    Merge PACS software. The firm name on the label is Merge Healthcare, Hartland, Wisconsin. Merge PACS 6.0 is software intended to create and display two-dimensional and three-dimensional images of anatomy from a series of digitally acquired images.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2325-2016·2016-08-10

    BK Medical bk3500 Ultrasound Scanner Recalled for Volume Calculation Error

    B-K Medical A/S is recalling six bk3500 ultrasound systems because the generic volume measurement function may display incorrect calculations, potentially affecting diagnostic accuracy.

    Product
    BK Medical ApS Ultrasound System Scanner bk2300 - Model #: bk3500 with software releases 1.2.0, 1.2.1 and 1.2.2. The system is intended for diagnostic ultrasound imaging or fluid flow analysis of the human body, data processing and guidance of puncture and biopsy. The system…
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-2336-2016·2016-08-10

    Zimmer Air Dermatome II Width Plate Recalled for Surface Coating Defects

    Zimmer Surgical Inc is recalling 70 units of Air Dermatome II Width Plates because the surface coating is blistering, peeling, and discoloring after use.

    Product
    Zimmer¿ Air Dermatome II Width Plate, 1 in., item number 00-8851-201-00 . Width plates is packaged inside of a padded-foam corrugate box. A product label is applied to the lid of the box. The width plates, when sold individually, are placed in a labeled poly zipper bag…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2335-2016·2016-08-10

    Zimmer Air Dermatome II Handpiece Recalled for Surface Coating Defects

    Zimmer Surgical Inc is recalling 220 Air Dermatome II handpieces because the surface coating is blistering, peeling, and discoloring after use.

    Product
    Zimmer¿ Air Dermatome II Handpiece w/o Hose, item number 00-8851-001-01. The Zimmer Air Dermatome II handpiece and width plates are packaged inside of a padded-foam corrugate box. An operating manual is packed with the handpiece between the top foam pad and box lid. A…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2319-2016·2016-08-10

    Medtronic StealthStation Software Recalled Due to Scanner Compatibility Issues

    Medtronic Navigation is voluntarily recalling 27 units of StealthStation software due to compatibility issues with specific floor-based scanners.

    Product
    MACH AxiEM Cranial Treon. The software application is sent in CD format with an IFU, wrapped in plastic with a label for shipping purposes. Product Usage: The StealthStation System is intended as an aid for precisely locating anatomical structures in either open or…
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.