The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

56151–56175 of 88419

  • HighFDA (Devices)·Z-1195-2017·2017-02-22

    Argon Medical Devices Recalls T-LOK Bone Marrow Biopsy Needles

    Argon Medical Devices is recalling T-LOK bone marrow biopsy needles due to a potential defect in the blister packaging that may compromise sterility.

    Product
    T-LOK BONE MARROW BIOPSY NEEDLE 8G x 4 EXT CAN; T-LOK BONE MARROW BIOPSY NEEDLE 11G x 4 EXT CAN Intended for the purpose of harvesting bone and/or bone marrow specimens
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1202-2017·2017-02-22

    Abbott StarClose SE Vascular Closure System Recall for Deployment Failure

    Abbott Vascular is recalling the StarClose SE Vascular Closure System because the device may fail to deploy the clip.

    Product
    StarClose SE Vascular Closure System, Part No. 14679-01, 14679-02. The UDI is 08717648079467. The GMDN is 47411.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Food)·F-1513-2017·2017-02-22

    Pier Fish Company Recalls Frozen Ground Tuna Due to Elevated Histamine Levels

    Pier Fish Company is recalling 34 cases of frozen ground tuna in Massachusetts and Ohio due to elevated histamine levels.

    Product
    Frozen Ground Tuna. Product is labeled in part: "PIER FISH CO. 68 CONWAY ST NEW BEDFORD, MA 02740 COLUMBUS FISH & SFD TUNA GRIND LOT# 16185 PRODUCT OF : USA HARVESTED: WILD CAUGHT NET WT: 20 LBS
    Category
    Food
    Distribution
    2 states
  • HighFDA (Food)·F-1481-2017·2017-02-22

    BWI Inc Recalls Burt's British Potato Chips Due to Gluten Mislabeling

    BWI Inc is recalling Burt's British Hand Cooked Potato Chips because they are labeled gluten-free but contain gluten. The recall covers 653 cases distributed in 24 U.S. states and the Grand Cayman.

    Product
    Burts British Hand Cooked Potato Chips Sea Salt & Malted Vinegar 150gx10 and 40gx20
    Category
    Food
    Distribution
    24 states
  • HighFDA (Devices)·Z-1197-2017·2017-02-22

    Advanced Sterilization Products Recalls STERRAD NX Sterilization Systems

    Advanced Sterilization Products is recalling STERRAD NX Sterilization Systems because the door interlock may disengage for 20 seconds after a power outage.

    Product
    STERRAD NX Sterilization System, Product Code: 10033, 10033-002
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1209-2017·2017-02-22

    Atrium Medical Recalls Maquet Express Dry Seal Suction Chest Drains

    Atrium Medical Corporation is recalling Maquet Express Dry Seal Suction chest drains because the manual vent valve may fail to re-seal after being depressed.

    Product
    Maquet Express Dry Seal Suction OCEAN DRAIN, SINGLE W/S Reference: 2002-300 Intended Use: To evacuate air and/or fluid from the chest cavity or mediastinum. " To help re-establish lung expansion and restore breathing dynamics. " To facilitate postoperative collection and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1203-2017·2017-02-22

    Merge Healthcare Recalls Schiller PB 1000 Blood Pressure Pumps

    Merge Healthcare is recalling Schiller PB 1000 blood pressure pumps because insufficient voltage causes them to fail before reaching adequate pressure.

    Product
    The Schiller PB 1000, also known as: Merge Hemo Patient Data Module (PDM), V2 model, a major component of the Merge Hemo software.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1205-2017·2017-02-22

    Atrium Medical Recalls Maquet Ocean Water Seal Chest Drains

    Atrium Medical is recalling Maquet Ocean Water Seal Chest Drains because the manual vent valve may fail to re-seal after being depressed.

    Product
    Maquet Ocean Water Seal Chest Drain, Single Collection WAC Reference: 2002-000 Intended Use: To evacuate air and/or fluid from the chest cavity or mediastinum. " To help re-establish lung expansion and restore breathing dynamics. " To facilitate postoperative collection and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1207-2017·2017-02-22

    Atrium Medical Recalls Maquet Oasis Chest Drains Due to Valve Defect

    Atrium Medical is recalling Maquet Oasis chest drains because the manual vent valve may fail to re-seal after use.

    Product
    Maquet Oasis Dry Suction Water Seal Chest Drain, Single Collection w/AC Reference: 3600-100 Intended Use: To evacuate air and/or fluid from the chest cavity or mediastinum. " To help re-establish lung expansion and restore breathing dynamics. " To facilitate postoperative…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1211-2017·2017-02-22

    Atrium Medical Recalls Maquet Express Dry Seal Suction OASIS Drain

    Atrium Medical Corporation is recalling 18 units of Maquet Express Dry Seal Suction OASIS Drain because the manual vent valve may fail to re-seal.

    Product
    Maquet Express Dry Seal Suction OASIS DRAIN, DRY PEDI W/AC Reference: 3612-100 Intended Use: To evacuate air and/or fluid from the chest cavity or mediastinum. " To help re-establish lung expansion and restore breathing dynamics. " To facilitate postoperative collection and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1212-2017·2017-02-22

    Siemens ARTISTE MV System Recalled for Collimator and Weld Defects

    Siemens is recalling 194 ARTISTE MV radiation therapy systems due to incorrect collimator position displays and improper weld seams.

    Product
    ARTISTE MV System, medical charged-particle radiation therapy system Product Usage: The intended use of the SIEMENS branded PRIMUS family of linear accelerator systems is to deliver x-ray radiation for therapeutic treatment of cancer.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1199-2017·2017-02-22

    Acumed Recalls 6-Hole Pubic Symphysis Plates Due to Material Error

    Acumed LLC is recalling 15 units of 6-hole Pubic Symphysis plates because they were manufactured with the wrong titanium alloy.

    Product
    6-hole Pubic Symphysis plate (PN 70-0451). The pelvic bone plates for the pelvic ring are a series of plates with varying lengths that function as internal fixation devices for fractures, fusions and osteotomies of the pelvic ring. The plates are strategically pre-contoured…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Food)·F-1468-2017·2017-02-22

    Pictsweet Farms Breaded Okra Recalled for Potential Glass Fragments

    The Pictsweet Company is recalling Southern Classics Crunchy Breaded Okra because the product may contain glass fragments.

    Product
    PICTSWEET(R) FARMS, Southern Classics, Crunchy Breaded Okra, NET WT 12 OZ (340g), UPC 7056098377
    Category
    Food
    Distribution
    15 states
  • HighFDA (Devices)·Z-1208-2017·2017-02-22

    Atrium Medical Recalls Maquet Express Dry Seal Suction Chest Drains

    Atrium Medical Corporation is recalling Maquet Express Dry Seal Suction Chest Drains because the manual vent valve may fail to re-seal after being depressed.

    Product
    Maquet Express Dry Seal Suction Chest Drain, Single Collection w/AC Reference: 4000-100N Intended Use: To evacuate air and/or fluid from the chest cavity or mediastinum. " To help re-establish lung expansion and restore breathing dynamics. " To facilitate postoperative…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1480-2017·2017-02-22

    Joe Chips Potato Chips Recalled for Potential Salmonella Contamination

    The Two Little Guys Company is recalling Joe Chips Sour Cream & Toasted Onion potato chips because a milk powder ingredient may be contaminated with Salmonella.

    Product
    Joe Chips Retro Potato Chips Sour Cream & Toasted Onion Distributed by: The Joe Tea Company, Upper Montclair, NJ 07043-0255 (973)744-7502 Net Wt. 2 OZ UPC 743234001725 Net Wt. 5 OZ UPC 743234001800
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1213-2017·2017-02-22

    Siemens Oncor Avant-garde Radiation Therapy Systems Recalled for Sensor Defects

    Siemens is recalling 194 Oncor Avant-garde radiation therapy systems due to incorrect collimator position displays and improper weld seams.

    Product
    ONCOR Avant-garde, medical charged-particle radiation therapy system Product Usage: The intended use of the SIEMENS branded PRIMUS family of linear accelerator systems is to deliver x-ray radiation for therapeutic treatment of cancer.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Drugs)·D-0474-2017·2017-02-22

    Aurobindo Recalls Venlafaxine Hydrochloride Capsules Due to Physical Defects

    Aurobindo Pharma USA Inc is recalling 47,040 bottles of Venlafaxine Hydrochloride extended-release capsules because some contain punctured or clumped capsules.

    Product
    VENLAFAXINE HYDROCHLORIDE — VENLAFAXINE HYDROCHLORIDE (VENLAFAXINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-1478-2017·2017-02-22

    Pizza Hut Creamy Alfredo Sauce Recalled for Foreign Object

    Yum Restaurants International is recalling Pizza Hut Creamy Alfredo sauce due to a likely flexible plastic foreign object.

    Product
    Pizza Hut Creamy Alfredo sauce, case size 40 lbs. 8 bags per case. Bags are each 80 oz (5 lbs) of sauce
    Category
    Food
    Distribution
    17 states
  • ModerateFDA (Devices)·Z-1222-2017·2017-02-22

    Atrium Thoracic Catheter Recall Due to Incorrect Labeling Icon

    Atrium Medical Corporation is recalling 1,394 cases of 10 Fr Straight Thoracic Catheters because the label icon incorrectly depicts six eyelets instead of two.

    Product
    Atrium PVC 10 Fr Straight Thoracic Catheter Code Number: 8010
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1217-2017·2017-02-22

    Siemens Enzyme II Calibrator Recalled for ALTI Result Shifts

    Siemens Healthcare Diagnostics is recalling Enzyme II Calibrators because they may cause patient and QC results to shift by up to 10% on the Dimension clinical chemistry system.

    Product
    The Enzyme II Calibrator is an in vitro diagnostic product for the Alanine Aminotransferase (ALTI) on the Dimension¿ clinical chemistry system. For prescription use only.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Drugs)·D-0476-2017·2017-02-22

    Actavis Recalls Glipizide Extended-Release Tablets Due to Dissolution Failure

    Actavis Inc is recalling specific lots of Glipizide extended-release tablets because they failed to meet dissolution specifications at the 10-hour testing point.

    Product
    Glipizide extended-release tablets, 2.5mg, 30-count bottle, Rx Only, Manufactured By Patheon Pharmaceuticals Inc Cincinnati OH 45237 USA, NDC 0591-0900-30, UPC 3-0591090030-4
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1204-2017·2017-02-22

    Siemens CentraLink Software Recalled for Potential Sample Type Omission

    Siemens is recalling CentraLink Data Management System software versions v13x, v14x, and v15x because the system may download orders to the ADVIA Automation System without specifying the sample type.

    Product
    CentraLink¿ Data Management System Software Versions: v13x,v14x,v15x The CentraLink system software is a network solution provider and multi-system data manager for the instruments and lab automation systems (LAS) within the lab. The CentraLink software consolidates data from…
    Category
    Medical Device
    Distribution
    Distributed nationwide