The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

5026–5050 of 88106

  • CriticalFDA (Food)·H-0196-2026·2025-11-26

    Mustard seed raw milk cheese recalled over two E coli strains

    Twin Sisters Creamery is recalling 237.34 pounds of raw milk Mustard Seed cheese due to E. coli O103:H2 and E. coli O74:H25. The FDA classified it Class I.

    Product
    Twin Sisters Creamery Mustard Seed cheese, 3lb. round cheese wheel, made with raw milk and aged at minimum of 60 days. Ingredients: Cultured raw cow's milk, salt, whole yellow mustard seeds and enzymes. Made in Ferndale, WA. www.twinsisterscreamery.com.
    Category
    Food
    Distribution
    2 states
  • CriticalFDA (Food)·H-0197-2026·2025-11-26

    Whatcom Blue cheese recalled over E coli O103 in raw milk

    Peterson Company is recalling 288 pieces of Twin Sisters Creamery Whatcom Blue cheese due to E. coli O103:H2. The FDA has classified the recall as Class I.

    Product
    Item# 28855 Whatcom Blue, Twin Sisters Creamery brand, product is packed in Cryovac and each package weighs 5oz-6oz. There are 16 pieces per case. This cheese is made from raw milk. Ingredients: cultured raw cow's milk, salt, enzymes, penicillium roqueforti. Made by Twin…
    Category
    Food
    Distribution
    4 states
  • CriticalFDA (Food)·H-0195-2026·2025-11-26

    Peppercorn raw milk cheese recalled over E coli O26 contamination

    Twin Sisters Creamery is recalling 115.46 pounds of raw milk Peppercorn cheese due to E. coli O26:H11. The FDA has classified the recall as Class I.

    Product
    Twin Sisters Creamery Peppercorn cheese, 3lb. round cheese wheel, made with raw milk and aged at minimum of 60 days. Ingredients: cultured raw cow's milk, whole peppercorns, salt, enzymes. Made in Ferndale, WA. www.twinsisterscreamery.com.
    Category
    Food
    Distribution
    2 states
  • CriticalFDA (Food)·H-0198-2026·2025-11-26

    Farmhouse white cheese recalled over E coli O103 in raw milk

    Peterson Company is recalling 288 pieces of Twin Sisters Creamery Farmhouse White cheese due to E. coli O103:H2. The FDA has classified the recall as Class I.

    Product
    Item# 29608 Farmhouse White, Twin Sisters Creamery brand, product is packed in Cryovac and each package weighs 5oz-6oz. This cheese is made from raw milk. Ingredients: cultured raw cow's milk, salt, enzymes, penicillium roqueforti. Made by Twin Sisters Creamery in Ferndale, WA.…
    Category
    Food
    Distribution
    4 states
  • CriticalFDA (Food)·H-0201-2026·2025-11-26

    Lobster bisque recalled over undeclared shrimp in bulk foodservice pouches

    Plenus Group is recalling 659 cases of Rockport Lobster Bisque because the product contains undeclared shrimp. The FDA has classified the recall as Class I.

    Product
    Rockport Lobser Bisque; packed in 2x8lb pouches and in 4x4b pouches
    Category
    Food
    Distribution
    10 states
  • CriticalFDA (Devices)·Z-0430-2026·2025-11-26

    Infusion pump modules recalled because drops can damage the bezel assembly

    CareFusion is recalling 2,574,396 BD Alaris Infusion Pump Modules 8100 because a dropped or jarred pump can suffer bezel damage causing under-infusion, over-infusion or unregulated flow.

    Product
    BD Alaris infusion Pump Module 8100, REF: 8100; KIT, BEZEL ASSY 8100BD, REF: 49000437; KIT ASSY ONE PIECE BEZEL 8100, REF: 49000270. Used with the following new and updated documents: BD Alaris Infusion System Inspection Safety Reminder, Part: BD-163124, Revision: 00…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0541-2026·2025-11-26

    Flow cytometers recalled over software that crashes during sample acquisition

    Beckman Coulter is recalling 25 DxFLEX Flow Cytometers because a software error crashes the system during acquisition on a patient sample when running a customer defined protocol.

    Product
    DxFLEX Flow Cytometer Catalog Number C78500 UDI-DI code: 15099590754013 The DxFLEX Flow Cytometer is intended for use as an in vitro diagnostic device for immunophenotyping up to ten fluorescent detection channels using three lasers (488 nm, 638 nm and 405 nm) and two light…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0517-2026·2025-11-26

    Laparotomy kits recalled over smoke pencils that may activate unprompted

    Medline is recalling 28,679 laparotomy convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) MAJOR LAPAROTOMY CDS, REF CDS860015W; 2) MAJOR LAPAROTOMY CDS, REF CDS860015X; 3) MINOR LAPAROTOMY CDS, REF CDS860016R; 4) MINOR LAPAROTOMY CDS, REF CDS860016S; 5) LAPAROTOMY CDS #31-RF, REF CDS860062S; 6) LAPAROSCOPY CDS, REF…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0506-2026·2025-11-26

    Heart pump controllers recalled over corrosion at the backup battery connector

    Thoratec is recalling 35,376 HeartMate 3 Controllers because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3 Controller (Standalone) Model/Catalog Number: 106531US, HeartMate 3 Controller, US; 106531INT, HeartMate 3 Controller, OUS; 106531LF2, HeartMate 3 Low Flow 2.0 Controller Software Version: N/A Product Description: The HeartMate…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0533-2026·2025-11-26

    Hemostasis valves recalled because the valve cap may remain depressed

    Merit Medical is recalling 217,141 PhD Hemostasis Valves because a manufacturing defect can leave the valve cap depressed, leading to potential leakage and possible hemorrhage.

    Product
    PhD Hemostasis Valve, REF: IN4802/K, IN4802/T, IN4918/A, IN7802/C, IN8802/C, IN9802, IN9802/A, K05-02166B, K05T-02138A, K12T-10798A, MAP800/B, MAP800/T, MAP801/B, MAP802/B, MAP802/CNB, MAP802/T, MAP804/B, MAP852/B, SKY1802.
    Category
    Medical Device
    Distribution
    49 states
  • HighFDA (Food)·H-0203-2026·2025-11-26

    Cinnamon powder recalled over elevated levels of lead in the spice

    Haitai is recalling 69 cases of Cinnamon Powder in 8 oz containers because of elevated levels of lead.

    Product
    Cinnamon Powder; 8oz clear plastic container. Distributed by Haitai Inc. UPC: 0 20914 81415 9
    Category
    Food
    Distribution
    0 states
  • HighFDA (Devices)·Z-0515-2026·2025-11-26

    Breast biopsy packs recalled over smoke pencils that may activate

    Medline is recalling 301 breast biopsy and mastectomy convenience packs containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) BREAST BIOPSY PACK-LF, REF DYNJ0160598C; 2) BIOPSY BREAST PACK, REF DYNJ65361A; 3) BREAST BIOPSY/MASTECTOMY, REF DYNJ908839A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0525-2026·2025-11-26

    Circumcision packs recalled over smoke pencils that may activate unprompted

    Medline is recalling 120 Circumcision Pack convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: CIRCUMCISION PACK, REF DYNJ16826O
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0574-2026·2025-11-26

    Reprocessed imaging catheters recalled after exceeding validated reprocessing cycles

    Sterilmed is recalling four reprocessed ACUSON AcuNav diagnostic ultrasound catheters because they were reprocessed beyond validated cycles.

    Product
    Brand Name: Sterilmed Reprocessed Imaging Catheter Product Name: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR FOR USE WITH SIEMENS SYSTEM Model/Catalog Number: ACU10135936 Software Version: N/A Product Description: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR FOR…
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-0513-2026·2025-11-26

    Vascular and open heart kits recalled over smoke pencils that may activate

    Medline is recalling 5,133 vascular, carotid and open heart convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) GENERAL AAA #11-RF, REF CDS840261AB; 2) CAROTID ENDARTERECTOMY CDS-LF, REF CDS983637I; 3) PERIPHERAL VASCULAR CDS, REF CDS983723J; 4) ACH OPEN HEART, REF CDS983773J; 5) VASCULAR, REF CDS984255K; 6) OPEN HEART CHILDRENS…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0571-2026·2025-11-26

    Blood tubes recalled after being manufactured without the gel separator

    Greiner Bio-One is recalling 1,980,000 Vacuette 8 ml serum separator tubes because some were manufactured without the gel separator, which could yield erroneous assay results.

    Product
    Brand Name: Vacuette Product Name: 8 ml CAT Serum Separator Clot Activator Model/Catalog Number: 455071P Product Description: Greiner VACUETTE Blood Collection Tube with Clot Activator and Gel Separator and Standard Stopper (16 x 100 mm, 8ml)
    Category
    Medical Device
    Distribution
    28 states
  • HighFDA (Devices)·Z-0568-2026·2025-11-26

    C difficile test kits recalled over buffer caps missing a gasket

    Meridian Bioscience is recalling alethia C. difficile nucleic acid amplification test assays because the reaction buffer tube cap may be missing its rubber gasket.

    Product
    Meridian Bioscience, alethia c. Difficile, Catalog Number 480050, Nucleic Acid Amplification Test Assay
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0573-2026·2025-11-26

    Non Siemens imaging catheters recalled after exceeding validated reprocessing cycles

    Sterilmed is recalling six reprocessed ACUSON AcuNav diagnostic ultrasound catheters, the variant not for use with Siemens systems, because they were reprocessed beyond validated cycles.

    Product
    Brand Name: ACUSON, CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR NOT FOR USE WITH SIEMENS SYSTEM Product Name: CATHETER ACUNAV DIAGNOSTIC ULTRASOUND 8FR NOT FOR USE WITH SIEMENS SYSTEM Model/Catalog Number: ACU10135910 Software Version: N/A Product Description: ACUSON, CATHETER…
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-0528-2026·2025-11-26

    LEEP procedure packs recalled over smoke pencils that may self activate

    Medline is recalling 18 GP-LEEP convenience packs containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: GP-LEEP PACK-LF, REF PHS396969004F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0529-2026·2025-11-26

    Minor eye trays recalled over smoke pencils that may stay active

    Medline is recalling 345 Minor Eye Tray #81 convenience kits containing SafeAir Smoke Evacuation Pencils, after Stryker expanded its recall of the pencils by 47 lots.

    Product
    MEDLINE convenience kits labeled as: 1) MINOR EYE TRAY #81, REF DYNJ27466S; 2) MINOR EYE TRAY #81, REF DYNJ27466T.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0569-2026·2025-11-26

    Group B strep test kits recalled over buffer caps missing gaskets

    Meridian Bioscience is recalling Group B Streptococcus nucleic acid amplification test assays because the reaction buffer tube cap may be missing its rubber gasket.

    Product
    Meridian Bioscience, Group B Streptococcus, Catalog Number 480050, Nucleic Acid Amplification Test Assay
    Category
    Medical Device
    Distribution
    14 states
  • HighFDA (Devices)·Z-0505-2026·2025-11-26

    Heart pump kits recalled over corrosion at the backup battery connector

    Thoratec is recalling 29,059 HeartMate 3 Left Ventricular System kits because potential corrosion at the backup battery cable connector may cause a Backup Battery Fault Alarm.

    Product
    Brand Name: HeartMate Product Name: HeartMate 3 Left Ventricular System (LVAS) Kits Model/Catalog Number: 106524US, HeartMate 3 LVAS KIT, US; 106524INT, HeartMate 3 LVAD KIT, OUS; 106524 Software Version: N/A Product Description: The HeartMate 3" Left Ventricular Assist…
    Category
    Medical Device
    Distribution
    Distributed nationwide