  • HighFDA (Devices)·Z-0331-2024·2023-11-29

    Endoscopic surgical instruments recalled for unvalidated drying process

    Aizu Olympus is recalling cystonephroscope endoscopes due to an unvalidated air drying process that allowed water to remain in instrument channels. Retained moisture poses a risk of contamination and infection.

    Product
    Cystonephroscope-endoscopic diagnosis and treatment within the bladder, urethra, and kidney Model Numbers: CYF-5, CYF-VH, CYF-VHR.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0392-2024·2023-11-29

    MRI Machine Gradient Coil Potential Failure Could Produce Smoke and Fire

    Philips Ingenia 1.5T CX MRI systems may experience gradient coil failure that could produce smoke and/or fire. The FDA has classified this as a Class II recall affecting 48 units distributed nationwide and internationally.

    Product
    Ingenia 1.5T CX
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0369-2024·2023-11-29

    Medline Manual Resuscitators Recalled for Backwards Manometer Leak

    Medline manual resuscitators are recalled due to a backwards leak in the integrated manometer that allows CO2 rebreathing. The defect affects multiple models used in respiratory care distributed nationwide.

    Product
    Medline manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. Adult Resuscitator REF #s: CPRM1116FPM, CPRM1116FPM4, CPRM1116M, CPRM1116MC, CPRM1116PM, CPRM1116PMT, CPRM1126FM, CPRM1126FPM, CPRM1126FPWM, CPRM1126M; 2. Infant…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0382-2024·2023-11-29

    Biomet Compress Device Anchor Plug Recall - Metal Burrs May Extend Surgery

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through, potentially extending operative time.

    Product
    Compress Device Short Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178560
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0348-2024·2023-11-29

    Uretero-reno fiberscopes recalled due to inadequate channel drying

    Aizu Olympus is recalling uretero-reno fiberscopes because the channel air drying process was not validated. A small percentage of repaired devices had residual water in the channels, creating a risk of contamination and infection.

    Product
    Uretero-reno fiberscope-For endoscopic diagnosis and treatment within the ureter and kidney. Model Numbers: URF-P7, URF-P7R, URF-V2, URF-V2R, URF-V3, URF-V3R.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0367-2024·2023-11-29

    V-Care manual resuscitators recalled for CO2 rebreathing defect

    SunMed's Ventlab V-Care manual resuscitators are being recalled due to a backwards leak in the integrated manometer that allows CO2 rebreathing. Affected devices were distributed nationwide.

    Product
    Ventlab, LLC V-Care manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. V-Care Child Resuscitator REF #s: VN4100MB, VN4100MCFB-3, VN4100MCP; 2. V-Care Infant Resuscitator REF #s: VN3100OB, VN3100MB-2, VN3100MB-M01, VNW3100MB-2…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0345-2024·2023-11-29

    Ultrasonic Gastrovideoscope Model TGF-UC180J Recalled for Inadequate Channel Drying

    Aizu Olympus is recalling ultrasonic gastrovideoscopes due to an unvalidated channel drying process that left some scopes with water in the channels after repair. Water remaining in the device poses a risk of contamination and infection.

    Product
    Ultrasonic gastrovideoscope-Real time ultrasound imaging,ultrasound guided needle aspiration and other endoscopic procedures within the upper gastrointestinal tract and surrounding organs Model Number: TGF-UC180J.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0323-2024·2023-11-29

    DBX Demineralized Bone Matrix Putty fill volume mislabeled

    DBX Demineralized Bone Matrix Putty units labeled as 10cc contain only 1cc of product, which may result in prolonged surgery. Affected units distributed in PA, TX, and WA.

    Product
    DBX Demineralized Bone Matrix Putty 10cc-Indicated for treatment of surgically created osseous defects or osseous defects created from traumatic injury. Model Number: 038100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0343-2024·2023-11-29

    Small intestinal videoscope recalled due to inadequate channel drying process

    Aizu Olympus is recalling small intestinal videoscopes (Model SIF-Q180) because the channel air drying process was not properly validated. Water remaining in the channels could cause contamination and infection risk.

    Product
    Small intestinal videoscope-For endoscopy and endoscopic surgery within the upper digestive tract (including the esophagus, stomach, duodenum, and small intestine) by oral insertion or the lower digestive tract (including the anus, rectum, sigmoid colon, colon, ileocecal valve…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0381-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent proper surgical installation and extend operation time. Distribution includes US nationwide and eight other countries.

    Product
    Compress Device Short Anchor Plug, 16 MM- Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178558
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0324-2024·2023-11-29

    Solea Laser Surgical Instrument Models 2.0 and 3.0 Recall for Unintended Activation

    Convergent Dental is recalling 39 Solea laser surgical instruments due to potential unintended laser activation without foot pedal depression. No injuries have been reported.

    Product
    Solea Models 2.0 and 3.0 Laser Surgical Instrument, Foot Pedal assembly SUB-00434 with foot pedal CUS-00226 Rev. K reworked
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0366-2024·2023-11-29

    Manual resuscitators recalled due to carbon dioxide rebreathing defect

    SunMed Holdings recalls Ventlab STAT-Check manual resuscitators due to a backwards leak in the integrated manometer allowing CO2 rebreathing, which may impair ventilation. Multiple models (Adult, Infant, Pediatric) are affected and distributed nationwide.

    Product
    Ventlab, LLC STAT-Check manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. STAT-Check Adult Resuscitator REF #: SC9101B; 2. STAT-Check Infant Resuscitator RES #s: SC7101B & SC7101B-M0; 3. STAT-Check Pediatric Resuscitator…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0351-2024·2023-11-29

    BD Extension Sets Mislabeled as DEHP-Free Despite Containing Phthalates

    Certain BD Extension Sets sold as free of DEHP (di(2-ethylhexyl) phthalate) actually contain this restricted phthalate. The products have been distributed worldwide.

    Product
    BD Extension Sets (Product Name, Catalog #) BD SmartSite Filter Extension Set PE lined Standard bore 1 SmartSite bonded 0.2um Large PES Filter 1 PC RLL. L: 16 in PV: 4mL, Catalog # 10013902 BD EXTENSION SET TRI-PORT SMALLBORE TUBING CHECK VALVE 3 SmartSite" VALVES, Catalog…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0340-2024·2023-11-29

    Mobile Airway Scope Recalled Due to Unvalidated Drying Process

    Aizu Olympus has recalled 33 Mobile Airway Scope units due to an unvalidated air drying process. Some repaired units had wet channels, creating a potential risk of contamination and infection.

    Product
    Mobile airway scope-diagnosis and observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: MAF-DM2, MAF-GM, MAF-GM2, MAF-TM, MAF-TM2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0395-2024·2023-11-29

    Philips MRI Gradient Coil Recall Due to Fire and Smoke Risk

    Philips is recalling SmartPath to dStream 1.5T MRI systems due to a potential gradient coil failure that could produce smoke or fire. The recall affects 119 units distributed nationwide and internationally.

    Product
    SmartPath to dStream for 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0396-2024·2023-11-29

    Boston Scientific EXALT Model D Duodenoscope Recall: Fluid Ingress in Lens

    Boston Scientific is recalling certain EXALT Model D Single-Use Duodenoscopes worldwide due to fluid ingress in the lens, which causes poor image quality. Affected devices should not be used; contact the manufacturer.

    Product
    EXALT Model D Single-Use Duodenoscope: Outer box UPN# M00542420 & Outer box UPN# M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0364-2024·2023-11-29

    RescuMed Manual Resuscitators Recalled for CO2 Rebreathing Risk

    SunMed Holdings recalls RescuMed manual resuscitators due to a backwards leak in the manometer allowing CO2 rebreathing. Affected models distributed nationwide across 32 US states.

    Product
    Ventlab, LLC RescuMed manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. RescuMed Adult Resuscitator REF #s: BVM510-F, BVMB510-10, BVMB510-F, BVMB510S-F; 2. RescuMed Infant Resuscitator REF #s: BVMB710 & BVMB710-F; 3.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0388-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled due to metal burrs

    Biomet is recalling Compress Device Short Anchor Plugs (28 MM, Item 178570) due to potential metal burrs in transverse holes that may prevent surgical instruments from passing through, extending surgery duration.

    Product
    Compress Device Short Anchor Plug, 28 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178570
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·23V804000·2023-11-29

    2024 Tiffin Allegro Bay motorhomes recalled for LPG hose defect

    Tiffin is recalling certain 2024 Allegro Bay and Allegro Open Road motorhomes because a 32-inch LPG hose fitting may not fit correctly, creating a fuel leak risk and fire hazard.

    Product
    TIFFIN — TIFFIN ALLEGRO BAY, ALLEGRO OPEN ROAD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0329-2024·2023-11-29

    Colonoscopes Recalled for Unvalidated Channel Drying Process and Infection Risk

    Aizu Olympus is recalling certain colonoscope models because the channel air drying process was not validated. A small percentage of repaired units had water remaining in the channel, which could lead to infection risk.

    Product
    Colonoscope: for endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum, sigmoid colon, colon and ileocecal valve). Model Numbers: CF-2T160I, CF-2T160L, CF-H170I, CF-H170L, CF-H180AI, CF-H180AL, CF-H180DI, CF-H180DL, CF-H190I, CF-H190L…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0335-2024·2023-11-29

    Hysteroscope Model HYF-1T recalled due to moisture in device channels

    Aizu Olympus is recalling Hysteroscope Model HYF-1T devices because the channel air drying process after repair was not validated. Some returned units had residual moisture that could allow contamination and infection.

    Product
    Hysteroscope-For endoscopic diagnosis within the uterus Model Number: HYF-1T.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0378-2024·2023-11-29

    Biomet Compress Device Anchor Plugs recalled for metal burrs in transverse holes

    Biomet is recalling Compress Device Short Anchor Plugs due to potential metal burrs in the transverse holes that may prevent proper placement of drill pins during surgery, potentially extending surgical time.

    Product
    Compress Device Short Anchor Plug, 10 MM-Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178552
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0327-2024·2023-11-29

    Bronchoscopes Recalled Due to Inadequate Air Drying Process

    Aizu Olympus recalls bronchoscopes due to unvalidated air drying process. Some returned units after repair contain water in channels, creating infection risk.

    Product
    Bronchoscope-for endoscopy and endoscopic surgery within the airways and tracheobronchial tree. Model Numbers: BF-1T150, BF-1T60, BF-1TH190, BF-1TQ170, BF-3C160, BF-3C40, BF-H190, BF-MP190F, BF-MP60, BF-P150, BF-P190, BF-P60, BF-Q170, BF-Q190, BF-XP190, BF-XP60, BF-XT160…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2024·2023-11-29

    Biomet Compress Anchor Plugs Recalled for Metal Burrs in Transverse Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs (18 MM) due to metal burrs in transverse holes that may prevent proper drill or pin placement, potentially extending surgery time.

    Product
    Compress Device Segmental Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178408
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0389-2024·2023-11-29

    Philips Achieva 1.5T MRI systems recalled for potential gradient coil fire risk

    Philips is recalling Achieva 1.5T MRI systems due to potential gradient coil failure that could produce smoke and/or fire. Approximately 520 units have been distributed nationwide and internationally.

    Product
    Achieva 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide