  • HighFDA (Devices)·Z-0749-2025·2025-01-01

    BD FACSLyric Flow Cytometer Power Supply Failure Risk

    BD is recalling FACSLyric flow cytometer power supplies that may fail to power on or stay on, creating risks of fume inhalation and requiring patients to return for repeat biospecimen collection procedures.

    Product
    FACSLyric 3L12C Instrument RUO, Catalog Number 663518, UDI 00382906635181
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0738-2025·2025-01-01

    Siemens Blood Analysis System Software Malfunction May Cause Patient Identification Error

    Siemens epoc NXS Host blood analysis systems are recalled due to a software malfunction that can assign incorrect patient names to blood tests, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413517(MX) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0737-2025·2025-01-01

    Blood Analysis System Software Malfunction May Assign Incorrect Patient Names

    Siemens epoc NXS Host blood analysis systems contain a software malfunction that may assign incorrect patient names to blood measurements. This could result in clinicians making treatment decisions based on the wrong patient's test results.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413506 (CA); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0165-2025·2025-01-01

    Duloxetine delayed-release capsules recalled due to manufacturing impurity

    Duloxetine delayed-release 60mg capsules are being recalled nationwide due to N-nitroso-duloxetine impurity above recommended interim limits. Two lot numbers are affected: J0786744-061724 (blister cards) and B3002625-060524 (bottles).

    Product
    Duloxetine Delayed-Release Capsules, 60 mg, a) 30 count blister cards (NDC 70518-0937-04), b) 30 count bottles (NDC 70518-0937-03), Rx only, Source NDC 57237-0019-99, MFG: Rising Pharma, Inc., Allendale, NJ, Repackaged by: RemedyRepack Inc., Indiana, PA
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0736-2025·2025-01-01

    Siemens epoc Blood Analysis System Recalled for Patient Identification Software Error

    Siemens is recalling epoc NXS Host blood analysis systems due to a software malfunction that can assign incorrect patient names to test results, potentially leading to misdiagnosis and mistreatment if not verified by the user.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413498(JP) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0760-2025·2025-01-01

    RUMMELL Medline Medical Device Weak Seals Sterility Risk Recall

    Medline RUMMELL units may have weak seals that could compromise sterility and increase infection risk. Approximately 21,440 units distributed nationwide are affected.

    Product
    RUMMELL, Medline Item No. ST006ST
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0751-2025·2025-01-01

    Daytona Small Stature Locking Caps recalled for manufacturing defects

    SeaSpine Orthopedics is recalling 92 Daytona Small Stature CoCr Locking Caps due to manufacturing defects that prevent proper component mating. The devices were distributed in seven U.S. states.

    Product
    Brand Name: Daytona Small Stature Product Name: CoCr LockingCap 4.5mm, Small Stature, T25, BT Model/Catalog Number: 79-0002 Software Version: N/A Product Description: Locking Cap Component: No
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0725-2025·2025-01-01

    Surgical Patties and Strips with Endotoxin Contamination in Medline Convenience Kits

    Medline Industries is recalling surgical patties and strips in specific lots of KIT,SPINE LH Convenience Kits due to higher-than-expected endotoxin levels in raw materials. The contamination may result in out-of-specification endotoxin in finished sterile products.

    Product
    KIT,SPINE LH Convenience kit, SKU DYNJ906448A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0756-2025·2025-01-01

    Medline Surgical Needle Holders Recalled for Sterility Compromise

    Medline is recalling 21,440 surgical needleholders due to weak seals that may compromise sterility and increase risk of contamination and infection during surgical use.

    Product
    ST OR MAYO HEGAR NEEDLEHOLDER 6"(OR2500), Medline Item No. 67870
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0767-2025·2025-01-01

    Siemens magnesium reagent cartridges recalled for false measurement results

    Siemens is recalling two lots of Magnesium Flex reagent cartridges due to potential falsely low magnesium measurements. The intermittent error may not be detected by standard quality control procedures.

    Product
    Magnesium Flex reagent cartridge, 360 tests, Catalog Number: K3057; Siemens Material Number (SMN): 10445158;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0155-2025·2025-01-01

    Duloxetine Delayed-Release Capsules Recalled for Nitrosamine Impurity

    Amerisource Health Services LLC is recalling Duloxetine Delayed-Release Capsules 30 mg nationwide due to N-nitroso-duloxetine impurity above recommended limits. Patients should contact their healthcare provider.

    Product
    Duloxetine Delayed-Release Capsules USP, 30 mg, Rx only, 30 count bottles, Manufactured by: Aurobindo Pharma Limited, Hyderabad-500 090, India, For BluePoint Laboratories NDC 68001-414-04
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0717-2025·2025-01-01

    Surgical Patties and Strips Recalled for Endotoxin Contamination

    Medline Industries recalls specific lots of surgical patties and strips in MAJOR NEURO PACK-LF Convenience kits due to higher-than-expected endotoxin levels detected in raw materials, which may have resulted in out-of-specification finished products.

    Product
    MAJOR NEURO PACK-LF Convenience kit, SKU DYNJ0578916X. Convenience kits used for various procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0748-2025·2025-01-01

    BD FACSLyric Flow Cytometer Power Supply Module Failure Risk

    BD is recalling power supply modules on FACSLyric flow cytometers that may fail to power on or stay on. Failure could cause lab staff to inhale fumes and patients to need repeat blood draws.

    Product
    FACSLyric 3L10C Instrument US-IVD, Catalog Number 662878, UDI 00382906628787 The K170974 clearance document describes the device as follows: The BD FACSLyric" flow cytometer (3-1, 4-2, 4-2-2, and 4-3-3 optical configurations) systems consist of a flow cytometer, sheath ta
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0757-2025·2025-01-01

    Sterile Magill Forceps Recalled Due to Weak Seals and Contamination Risk

    Medline has recalled Sterile Magill Forceps (Item No. 66790) due to weak seals that may compromise sterility. The defect affects approximately 21,440 units distributed nationwide.

    Product
    STERILE MAGILL FORCEP (MAGF9), Medline Item No. 66790
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0758-2025·2025-01-01

    Medline Reprocessed Bruns Curette Surgical Instruments Recalled for Weak Sterile Seals

    Medline is recalling 21,440 reprocessed Bruns curettes due to weak sterile seals that may fail without user detection. This increases the risk of contamination and infection.

    Product
    ST REPROCESSED BRUNS CURETTE #00 (BC00), Medline Item No. 67600K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0164-2025·2025-01-01

    Diagnostic drug kit recalled due to sterility concerns and vial integrity issues

    Curium US is recalling Technetium TC 99m Sestamibi diagnostic kits (Lot 092-24006) due to improper vial crimps that could compromise sterility assurance. The recall affects approximately 5,160 vials distributed nationwide.

    Product
    TECHNETIUM TC 99M SESTAMIBI — TECHNETIUM TC 99M SESTAMIBI (TECHNETIUM TC 99M SESTAMIBI)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0723-2025·2025-01-01

    Medline surgical patties and strips recalled for endotoxin contamination

    Medline surgical patties and strips used in certain procedure convenience kits were found to contain higher-than-expected endotoxin levels that may exceed safety specifications. The affected kits were distributed nationwide and in Canada.

    Product
    Medline brand, medical procedure convenience kits, labeled as: 1) CRANIOTOMY, SKU CDS982719X; 2) MVFF/FIBU #54-RF, SKU DYNJ21927Q; 3) MVFF/FIBU #54-RF, SKU DYNJ21927S; 3) NEURO PEDIATRIC, SKU DYNJ61607A; 4) CRANIOTOMY PACK, SKU DYNJ66419C; 5) LYMPHATIC BYPASS PACK, SKU DYNJ69907;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0160-2025·2025-01-01

    Chlorpromazine Hydrochloride tablets recalled for manufacturing impurity excess

    Glenmark Pharmaceuticals is recalling Chlorpromazine Hydrochloride tablets due to manufacturing deviations that resulted in an impurity exceeding FDA limits. The affected lot (17230133, expiring 12/31/2024) was distributed nationwide.

    Product
    CHLORPROMAZINE HYDROCHLORIDE — CHLORPROMAZINE HYDROCHLORIDE (CHLORPROMAZINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0759-2025·2025-01-01

    Medline ST IUD Removal Hook Recalled Due to Weak Seals and Sterility Risk

    Medline Industries is recalling 21,440 units of the ST IUD Removal Hook due to weak seals that may compromise sterility. The defect is undetectable to users and could increase infection risk.

    Product
    ST IUD REMOVAL HOOK 10" (504090), Medline Item No. I68785
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0766-2025·2025-01-01

    EMPOWR 3D Knee Tibial Insert Package Mix-Up Causes Surgical Delays

    Encore Medical recalls EMPOWR 3D Knee Tibial Insert packages that may contain the wrong size implant (5R 16MM with 3R 14MM and vice versa), potentially delaying surgery. The recall affects 33 units nationwide.

    Product
    EMPOWR 3D Knee Tibial Insert, 5R 16MM, VE, REF: 342-16-705; EMPOWR 3D Knee Tibial Insert, 3R 14MM, VE, REF: 342-14-703
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0743-2025·2025-01-01

    3M Clarity Precision Orthodontic Attachments Recall for Improper Tooth Mating

    3M is recalling Clarity Precision Grip Attachments due to a design defect that may prevent proper fitting with digital treatment plans. The recall affects 171 orders distributed in the US, Canada, Australia, and New Zealand.

    Product
    Clarity Precision Grip Attachments, for use in orthodontic treatment. Part numbers/SKUs: 359-830 359-831 359-832 359-833 359-834 359-835 359-836 359-837
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0754-2025·2025-01-01

    Sterile Kelly Hemostat Recalled Due to Weak Seals

    Medline's STERILE STRT KELLY HEMOSTAT (SK8039S) is being recalled due to weak seals that could compromise sterility, increasing the risk of contamination and infection. The recall affects 21,440 units distributed nationwide.

    Product
    STERILE STRT KELLY HEMOSTAT (SK8039S), Medline Item No. 66695
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0735-2025·2025-01-01

    Blood analyzer system recalled for patient name assignment software error

    Siemens recalled its epoc NXS Host blood analyzer due to a software malfunction that can assign incorrect patient names to test results, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413497 (EU); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or capi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0718-2025·2025-01-01

    Surgical patties and strips recalled due to endotoxin contamination

    Medline Industries is recalling FESS-MB PACK-LF Convenience kits containing surgical patties and strips due to higher-than-expected endotoxin levels in raw materials, resulting in out-of-specification finished products.

    Product
    FESS-MB PACK-LF Convenience kit, SKU DYNJ0888159I. Convenience kits used for various procedures..
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0740-2025·2025-01-01

    Siemens Blood Analysis Device Recalled Over Patient Name Mix-up Software Defect

    Siemens is recalling the epoc NXS blood analysis system due to a software flaw that can assign incorrect patient names to test results, risking misdiagnosis or mistreatment if the operator doesn't verify the patient name.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413583(CN, KR) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or
    Category
    Medical Device
    Distribution
    Distributed nationwide