58076–58100 of 74005

  • SevereNHTSA·14V367000·2014-06-25

    Freightliner Trucks Recalled for Potential Axle Beam Weakness

    Daimler Trucks North America is recalling 2015 Freightliner trucks because axle manufacturing errors may create weak spots, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER M2, CASCADIA, 122SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1785-2014·2014-06-25

    Convatec Recalls Flexi-Seal Fecal Management System for Regulatory and Performance Issues

    Convatec Inc. is recalling the Flexi-Seal Fecal Management System because it lacks FDA 510(k) clearance and its Auto-Valve feature is not performing consistently.

    Product
    Convatec Flexi Seal Control Fecal Management System Rx Only REF 411107 Product Usage:For use to manage fecal incontinence through the collection of liquid to semi-liquid stool and to provide access to administer medications as prescribed by a physician.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1399-2014·2014-06-25

    John W Hollis Inc Recalls Compounded Injectable Products Due to Sterility Concerns

    John W Hollis Inc is recalling specific lots of compounded injectable products containing papaverine, phentolamine, and alprostadil due to a lack of assurance of sterility.

    Product
    Papaverine HCl 30 mg, Phentolamine Mesylate 2 mg, Alprostadil 40 mcg, a) 5 mL and b) 10 mL, JOHN HOLLIS Pharmacist, Inc, 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1386-2014·2014-06-25

    Actavis Recalls Subpotent Vancomycin Hydrochloride Capsules Nationwide

    Actavis Inc is recalling 6,913 packages of Vancomycin Hydrochloride Capsules because the drug is subpotent. The recall covers distribution across the United States.

    Product
    Vancomycin Hydrochloride Capsules, USP, 250 mg. 20 Capsules on 2 x 10 Capsule Blister Cards, Rx Only. Mfd. for: Watson Pharma Inc., Parsippany, NJ 07054 USA. Mfd. by: Patheon Pharmaceuticals Inc., Cincinnati, OH 45237 USA. NDC 0591-3561-15.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1394-2014·2014-06-25

    John W Hollis Recalls Mannitol 5% Solution for Injection Due to Sterility Concerns

    John W Hollis Inc. is recalling specific lots of Mannitol 5% Solution for injection because the products lack assurance of sterility.

    Product
    Mannitol 5% Solution for injection, Mannitol 50 mg, also contains Sterile Water for Injection, Chlorobutanol USP, 50 mL, JOHN HOLLIS Pharmacist, Inc. 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1405-2014·2014-06-25

    John W Hollis Inc Recalls Pyridoxine HCl Injectable Due to Sterility Concerns

    John W Hollis Inc is recalling Pyridoxine HCl 100mg injectable products because they lack assurance of sterility. Consumers should stop using the product and contact their pharmacist.

    Product
    PYRIDOXINE HCL, Pyridoxine HCl 100mg, Also Contans: Benzyl Alcohol, Sodium Chloride, Water, Hydrochloric Acid, and/or Sodium Hydroxide, 30 mL, JOHN HOLLIS Pharmacist, Inc, 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1391-2014·2014-06-25

    John W Hollis Recalls Polidocanol 5% Injection Due to Sterility Concerns

    John W Hollis Inc is recalling Polidocanol 5% Solution for Injection because the company cannot ensure the product is sterile.

    Product
    Polidocanol 5% Solution for Injection, each mL contains Polidocanol (Laureth 9) 50 mg, also contains Sterile Water for Injection, Ethyl Alcohol, Anhydrous Chlorobutanol, 50 mL Vial, JOHN HOLLIS Pharmacist Inc, Inc. 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1401-2014·2014-06-25

    John W Hollis Inc Recalls Compounded Injectable Drug Due to Sterility Concerns

    John W Hollis Inc is recalling a compounded injectable drug product due to a lack of assurance of sterility. The product is distributed nationwide.

    Product
    Papaverine HCl 30 mg, Phentolamine Mesylate 2 mg, Alprostadil 20 mcg, 10 mL, JOHN HOLLIS Pharmacist, Inc 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1389-2014·2014-06-25

    John W Hollis Inc Recalls Liver Derivative Complex Injection for Sterility Concerns

    John W Hollis Inc is recalling specific lots of Liver Derivative Complex for injection due to a lack of assurance of sterility in the compounded aseptically filled products.

    Product
    Liver Derivative Complex for injection, each mL contains: Liver Derivative Complex 25.5mg, also contains: Water for Injection, Phenol 0.5%, HCl or NaOH to adjust pH, 10 mL, Compounded by Prescription: JOHN HOLLIS Pharmacist Inc, 110 20th Avenue N, Nashville, TN 37203…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1397-2014·2014-06-25

    John W Hollis Inc Recalls Compounded Injectable Products Due to Sterility Concerns

    John W Hollis Inc is recalling specific lots of compounded injectable products containing papaverine, phentolamine, and alprostadil due to a lack of sterility assurance.

    Product
    Papaverine HCl 30 mg, Phentolamine Mesylate 1 mg, Alprostadil 20 mcg, a) 5 mL and b) 10 mL, JOHN HOLLIS Pharmacist, Inc, 110 20th Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1403-2014·2014-06-25

    John W Hollis Inc Recalls Compounded Injectable Products Due to Sterility Concerns

    John W Hollis Inc is recalling compounded injectable products containing papaverine, phentolamine, and alprostadil due to a lack of sterility assurance.

    Product
    Papaverine HCl 30 mg, Phentolamine Mesylate 1 mg, Alprostadil 10 mcg, a) 5 mL and b) 10 mL, JOHN HOLLIS Pharmacist, Inc, 110 20th Avenue N, Nashville, TN 37203 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1406-2014·2014-06-25

    John W Hollis Recalls Polidocanol 1% Injection Due to Sterility Concerns

    John W Hollis Inc. is recalling Lot 2868 of Polidocanol 1% Solution for Injection because the company cannot ensure the product is sterile.

    Product
    Polidocanol 1% Solution for Injection, each mL contains Polidocanol (Laureth 9) 10 mg, also contains Sterile Water for Injection, Ethyl Alcohol, Anhydrous Chlorobutanol, 50 mL, JOHN HOLLIS Pharmacist, Inc. 110 B2 Avenue N, Nashville, TN 37203, 615-327-3234
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1798-2014·2014-06-25

    Boston Scientific Recalls IntellaTip MiFi XP Temperature Ablation Catheters

    Boston Scientific is recalling 968 IntellaTip MiFi XP Temperature Ablation Catheters because some units were not manufactured according to specification.

    Product
    IntellaTip MiFi XP Temperature Ablation Catheter; 10m x 8F (2.67mm) Large Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1837-2014·2014-06-25

    Biomet G7 Acetabular System Positioning Guide Rod Recalled for Fracture Risk

    Biomet is recalling G7 Acetabular System Positioning Guide Rods because they may fracture during surgery, potentially causing retained fragments or surgical delays.

    Product
    G7 Acetabular System Positioning Guide Rod, orthopedic surgical instrument for hip prosthesis PN 110003458.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1827-2014·2014-06-25

    Philips MR Trolley Recall for Foot Clamping Hazard

    Philips is recalling Height Adjustable FlexTrak trolleys and Trolley Variable Height IRFs for Ingenia MR systems due to a risk of foot clamping.

    Product
    Philips MR systems: Trolley Variable Height IRF (for Ingenia 1.5T & 3.0T products) Product Usage: Diagnostic MR System. The Height Adjustable FlexTrak trolley and Trolley Variable Height IRF is an optional device designed to prepare the patient outside the examination room…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1794-2014·2014-06-25

    Boston Scientific Recalls IntellaTip MiFi XP Temperature Ablation Catheters

    Boston Scientific is recalling 968 IntellaTip MiFi XP Temperature Ablation Catheters because some units were not manufactured according to specification.

    Product
    IntellaTip MiFi XP Temperature Ablation Catheter; 8mm x 8F (2.67mm) Standard Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1809-2014·2014-06-25

    Nellcor Puritan Bennett PB840 Ventilator Display Component Recalled

    Nellcor Puritan Bennett Inc. is recalling Backlight Inverter Printed Circuit Boards for PB840 Ventilators due to a potential loss of the graphical user interface display.

    Product
    Model Number(s): PB840 Ventilator (4-840120DIUU-XX). The product is a component of the Puritan Bennett 840 Ventilator: The Backlight Inverter Printed Circuit Board (BLI PCBA) for the 9.4 Display part number 4-079056-00. The PB840 Ventilator System is intended to provide…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1803-2014·2014-06-25

    Biomet Recalls EZPass Suture Passer Due to Wire Buckling

    Biomet, Inc. is recalling 102 EZPass Suture Passers because the nitinol wire may buckle and become kinked, making the instrument difficult to use.

    Product
    EZPass Passer, Sterile single use arthroscopic instrument utilized in conjunction with a nitinol wire to aid in passing suture through soft tissue. Part numbers 904050, 904051, 904052, 904053, 904054, 904055, and 904056.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·14216·2014-06-25

    Julie Vos Women's Scarves Recalled for Flammability Violation

    Julie Vos is recalling about 324 women's scarves because they fail to meet federal flammability standards, posing a risk of burn injury.

    Product
    Julie Vos women's scarves
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1806-2014·2014-06-25

    RayStation Software Recall for Radiation Therapy Dose Calculation Errors

    RaySearch Laboratories is recalling RayStation software version 4.0.3.4 due to a bug that causes incorrect dose calculations for radiation therapy plans with variable CT slice spacing.

    Product
    RayStation software version 4.0.3.4 RayStation is a software system designed for treatment planning and analysis of radiation therapy.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1796-2014·2014-06-25

    Boston Scientific Recalls IntellaTip MiFi XP Temperature Ablation Catheters

    Boston Scientific is recalling 968 IntellaTip MiFi XP Temperature Ablation Catheters because some units were not manufactured according to specification.

    Product
    IntellaTip MiFi XP Temperature Ablation Catheter; 8mm x 8F (2.67mm); Asymmetric Curve. The BSC Controller and Accessories are indicated for use in conjunction with standard and high power catheters for cardiac ablation procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1838-2014·2014-06-25

    Biomet G7 Acetabular System Positioning Guide Post Recalled for Fracture Risk

    Biomet is recalling G7 Acetabular System Positioning Guide Posts because the guide rod may fracture during surgery, potentially causing a delay in the procedure.

    Product
    G7 Acetabular System Positioning Guide Post, orthopedic surgical instrument for hip prosthesis. PN:110003500.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1826-2014·2014-06-25

    Philips Ingenia FlexTrak Trolley Recalled for Foot Clamping Hazard

    Philips is recalling Ingenia HA FLEX TRAK Trolleys because the central column can clamp a patient's foot. The recall covers 420 units distributed worldwide.

    Product
    Philips MR systems: Ingenia HA FLEX TRAK Trolley (for Ingenia 1.5T & 3.0T products) Product Usage: Diagnostic MR System. The Height Adjustable FlexTrak trolley and Trolley Variable Height IRF is an optional device designed to prepare the patient outside the examination room…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1824-2014·2014-06-25

    Spacelabs Ventilator Interface Recalled for Minute Volume Display Error

    Spacelabs Healthcare is voluntarily recalling Ventilator Flexport Interfaces because the bedside monitor may display minute volume values up to ten times the actual value.

    Product
    Spacelabs Healthcare Ventilator Flexport Interface, Model 90436A-07
    Category
    Medical Device
    Distribution