2901–2925 of 82415

  • SevereNHTSA·26V168000·2026-03-19

    IC Bus school bus body joints may lack sufficient epoxy coverage

    International is recalling certain 2023-2027 IC Bus CESB and 2025-2027 IC Bus EVSB school buses because the body panel joint may have been attached without sufficient epoxy coverage.

    Product
    IC BUS — IC BUS EVSB, CESB
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V169000·2026-03-19

    2026 Hyundai Palisade Hybrid seat belt buckle wiring defect recall

    Hyundai is recalling certain 2026 Palisade and Palisade Hybrid vehicles with Limited and Calligraphy trim packages due to damaged wiring in the third-row driver-side seat belt buckle that may prevent the warning indicator from alerting to unfastened belts.

    Product
    HYUNDAI — HYUNDAI PALISADE HYBRID, PALISADE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V166000·2026-03-19

    GM Recalls 2018-2019 Trucks for Roof Rail Air Bag Defect

    General Motors is recalling 2018-2019 Chevrolet and GMC trucks because roof rail air bag inflators may rupture, posing an injury risk.

    Product
    CHEVROLET — CHEVROLET, GMC SILVERADO 1500, SIERRA 1500, SILVERADO 2500, SILVERADO 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26332·2026-03-19

    Goregent infant walkers fail mandatory doorway and step edge requirements

    Goregent infant walkers are being recalled because they can fit through a standard doorway and fail to stop at the edge of a step, violating the mandatory standard for infant walkers.

    Product
    Goregent Infant Walkers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26330·2026-03-19

    Specialized Como SL bicycle fork steerer tubes can develop fatigue cracks

    Specialized is recalling bicycle forks on all Turbo Como SL electric bicycles because the fork steerer tube can develop a small fatigue crack leading to progressive failure of the fork.

    Product
    Specialized Turbo Como SL 4.0 & 5.0 Bicycle Forks
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·26V167000·2026-03-19

    Terex Recalls Digger Utility Trucks Due to Pole Guide Weld Defect

    Terex is recalling 2019-2026 digger utility trucks because a weld defect may cause the pole guide arm to fall, posing an injury risk.

    Product
    TEREX — TEREX GENERAL 65, GENERAL 80, C4000, C5000
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26334·2026-03-19

    Amazon Basics folding pocket knife may not stay secured closed

    Amazon is recalling the Amazon Basics Camping Folding Pocket Knife because the folding mechanism can fail to remain properly secured in the closed position, posing a laceration hazard.

    Product
    Amazon Basics Camping Folding Pocket Knives
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26331·2026-03-19

    BUILT LUUM light up tumblers can break exposing button cell batteries

    Lifetime Brands is recalling BUILT LUUM light up tumblers because they can break, making the button cell batteries accessible to children and posing choking and ingestion hazards.

    Product
    BUILT LUUM Tumblers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1548-2026·2026-03-18

    TRUE METRIX GO manuals recalled as Class I over E-5 error guidance

    Trividia Health is recalling owner's booklets and instructions for TRUE METRIX GO blood glucose meters because the labeling did not give lay users adequate directions for the E-5 error code.

    Product
    Owner's Booklets and Instructions for Use that are used with the following blood glucose measuring devices. Description/Item: Walgreens TRUE METRIX GO Kit/RF4001-01BK, CVS TRUE METRIX GO Kit/RF4007-01, Meijer TRUE METRIX GO Kit/RF4019-01, Fred's Phamarcy TRUE METRIX GO Kit/R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1546-2026·2026-03-18

    TRUE METRIX PRO manuals recalled as Class I over E-5 guidance

    Trividia Health is recalling owner's booklets and instructions for TRUE METRIX PRO blood glucose meters because the labeling did not give lay users adequate directions for the E-5 error code.

    Product
    Owner's Booklets and Instructions for Use that are used with the following blood glucose measurement devices. Description/Item: TRUE METRIX PRO Meter Only/RE4H01P-40, TRUE METRIX PRO Starter Kit/RE4H01P-43, PROCURE TRUE METRIX PRO Meter Only/RE4212P-00, Henry Schein TRUE MET
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1545-2026·2026-03-18

    TRUE METRIX manuals recalled as Class I over E-5 error code guidance

    Trividia Health is recalling owner's booklets and instructions for TRUE METRIX blood glucose meters because the labeling did not give lay users adequate directions for the E-5 error code.

    Product
    Owner's Booklets and Instructions for Use that are used with the following blood glucose measuring devices. Description/Item: Walgreens TRUE METRIX Kit/RE4001-01, Leader TRUE METRIX Kit/RE4002-01, Leader TRUE METRIX Meter Only/RE4002-40, CVS TRUE METRIX Kit/RE4007-01SB, GN
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1547-2026·2026-03-18

    TRUE METRIX AIR manuals recalled as Class I over E-5 guidance

    Trividia Health is recalling owner's booklets and instructions for TRUE METRIX AIR blood glucose meters because the labeling did not give lay users adequate directions for the E-5 error code.

    Product
    Owner's Booklets and Instructions for Use that are used with the following blood glucose measuring devices. Description/Item: Walgreens TRUE METRIX AIR Kit/REA4001-01, Leader TRUE METRIX AIR Kit/REA4002-01, CVS TRUE METRIX AIR Kit/REA4007-01, GNP TRUE METRIX AIR Kit/REA4011-
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·H-0546-2026·2026-03-18

    Rosabella Brand Moringa Dietary Supplement Capsules Contaminated with Salmonella

    Ambrosia Brands LLC is recalling Rosabella brand Moringa dietary supplement capsules nationwide and internationally because the product may be contaminated with Salmonella.

    Product
    Rosabella brand MORINGA; DIETARY SUPPLEMENT CAPSULES; 60 capsules per bottle; Distributed by: Ambrosia Brands, LLC, 625 Randall Ave, St. 100, Cheyenne, WY 82001; SUGGESTED USE: As a dietary supplement, take two (2) veggie capsules once a day. For best results, take 20-30 min befo
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1556-2026·2026-03-18

    Artelon FlexBand Twist anchors failed bacterial endotoxin testing

    International Life Sciences is recalling the Artelon FlexBand Twist .12, ref TW012, because the augmentation devices failed bacterial endotoxin testing.

    Product
    Artelon FLEXBAND TWIST .12 Ref: TW012 3.85x17mm HEX Anchor (Qty 2) 5.0x17mm HEX Anchor (Qty 1) 0.5x12cm FLEXBAND (Qty 1)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1555-2026·2026-03-18

    Artelon FlexBand Plus implants failed bacterial endotoxin testing

    International Life Sciences is recalling Artelon FlexBand Plus, refs 41054 and 41057, because the augmentation devices failed bacterial endotoxin testing.

    Product
    Artelon FlexBand Plus Ref: 41054 & 41057
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1497-2026·2026-03-18

    IBA proton therapy system may not interrupt beam when gating fails

    Ion Beam Applications is recalling PROTEUS 235 proton therapy systems because a disabled interface means the safety system may not interrupt beam delivery if the external gating signal is lost.

    Product
    IBA Proton Therapy System - PROTEUS 235
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1524-2026·2026-03-18

    GEM Premier 5000 PAK part 00055360004 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055360004 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK, Part No. 00055360004.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1527-2026·2026-03-18

    GEM Premier 5000 PAK part 00055360011 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055360011 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055360011.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V161000·2026-03-18

    2026 Keystone Montana Fifth Wheel Recreational Trailers Electrical Wiring Recall

    Keystone is recalling certain 2026 Montana fifth wheel trailers because improperly secured 12-volt and 120-volt wiring may be pinched and damaged when the bedroom slide-out moves, increasing fire risk.

    Product
    KEYSTONE — KEYSTONE MONTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1551-2026·2026-03-18

    EndoVive PEG kits recalled over compromised ChloraPrep swabstick seals

    Boston Scientific is recalling EndoVive Safety PEG Kits containing BD ChloraPrep Triple Swabsticks because open or compromised seals on the swabstick packaging could cause loss of sterility.

    Product
    EndoVive Safety PEG Kit; Outer Box Material Number (UPN): M00509001; Inner Box Material Number (UPN): M00509000;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1498-2026·2026-03-18

    Raz shower commode chair seat may be reinstalled without engaging brackets

    Raz Design is recalling several Mobile Shower Commode Chair models because a vendor modification means the seat may be reinstalled without properly engaging the outside rear seat brackets that hold it in place.

    Product
    Raz-AT (Attendant Tilt) Mobile Shower Commode Chair, Catalog Number Z300 UDI-DI code: (01)00628758003007 Raz-ART (Attendant Rotational Tilt) Mobile Shower Commode Chair, Catalog Number Z333 UDI-DI code: (01)00628758003335 Raz-AT600 (Bariatric Tilt) Mobile Shower Commode C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1552-2026·2026-03-18

    Beckman Coulter DxC 700 AU analyzer may stop analyzing after errors

    Beckman Coulter is recalling DxC 700 AU analyzers because leaving the calibration monitor open beyond 15 minutes can trigger database errors that stop the system analyzing.

    Product
    DxC 700 AU, REF: B86444, B86446
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1532-2026·2026-03-18

    GEM Premier 5000 PAK part 00055415004 may eject during warm-up

    Instrumentation Laboratory is recalling GEM Premier 5000 PAK part 00055415004 after confirmed complaints of Process Control Solution Not Detected errors during warm-up causing cartridge ejection.

    Product
    GEM Premier 5000 PAK; Part No. 00055415004.
    Category
    Medical Device
    Distribution
    Distributed nationwide