The Recall Desk

State

Tennessee product recalls

73,892 recalls have nationwide distribution and so reach Tennessee. 7,863 additional recalls listed Tennessee specifically in their distribution scope.

What the numbers show

Total
7,863
Critical
1,324
Severe
1,975
Most recent
2026-11-14

Of the 7,863 recalls naming Tennessee we have scored against our rubric, 1,324 (17%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,975 (25%) are Severe.

These figures cover only the 7,863 recalls whose distribution notice names Tennessee specifically. The 73,892 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

65726–65750 of 81755

  • CriticalFDA (Drugs)·D-1170-2014·2014-03-26

    Silver Sword capsules recalled for undeclared sildenafil ingredient

    Fabscout Entertainment is recalling Silver Sword capsules because FDA analysis found they contain sildenafil, an undeclared active pharmaceutical ingredient.

    Product
    Silver Sword capsules, 180 mg, 16-count clamshell tin, UPC 1 234658 970128 12345 (labeling is in foreign language)
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1160-2014·2014-03-26

    Baxter Recalls Clinimix IV Bags Due to Particulate Matter

    Baxter Healthcare is recalling 7,388 bags of Clinimix 5/15 sulfite-free IV solution because they contain particulate matter, including wood, sodium citrate, and dextrose.

    Product
    CLINIMIX — CLINIMIX (LEUCINE, PHENYLALANINE, LYSINE, METHIONINE, ISOLEUCINE, VALINE, HISTIDINE, THREONINE, TRYPTOPHAN, ALANINE, GLYCINE, ARGININE, PROLINE, SERINE, TYROSINE, DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1158-2014·2014-03-26

    Baxter Recalls Clinimix E Bags Due to Particulate Matter

    Baxter Healthcare is recalling 14,574 bags of Clinimix E IV solution found to contain particulate matter, including wood, sodium citrate, and dextrose.

    Product
    CLINIMIX E — CLINIMIX E (LEUCINE, PHENYLALANINE, LYSINE, METHIONINE, ISOLEUCINE, VALINE, HISTIDINE, THREONINE, TRYPTOPHAN, ALANINE, GLYCINE, ARGININE, PROLINE, SERINE, TYROSINE, DIBASIC POTASSIUM PHOSPHATE, MAGNESIUM CHLORIDE, SODIUM CHLORIDE, CALCIUM CHLORIDE, DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1211-2014·2014-03-26

    Abbott FreeStyle Blood Glucose Monitors Recalled for Inaccurate Results

    Abbott Diabetes Care is recalling FreeStyle Blood Glucose Monitors because they may produce inaccurate blood glucose readings when used with specific test strips.

    Product
    FreeStyle Blood Glucose Monitors System. For in vitro diagnostic use only. Store at room temperature below 86 degrees F (30 degrees C). Use test strips only within the system operating temperature range as outlined in your Owner's Booklet. Meter made in China…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1159-2014·2014-03-26

    Baxter Recalls Clinimix E IV Bags Due to Particulate Matter

    Baxter Healthcare is recalling 7,068 bags of Clinimix E IV solution because they contain particulate matter, including wood, sodium citrate, and dextrose.

    Product
    CLINIMIX E — CLINIMIX E (LEUCINE, PHENYLALANINE, LYSINE, METHIONINE, ISOLEUCINE, VALINE, HISTIDINE, THREONINE, TRYPTOPHAN, ALANINE, GLYCINE, ARGININE, PROLINE, SERINE, TYROSINE, DIBASIC POTASSIUM PHOSPHATE, MAGNESIUM CHLORIDE, SODIUM CHLORIDE, CALCIUM CHLORIDE, DEXTROSE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1161-2014·2014-03-26

    Hospira Recalls Marcaine Injection Vials Due to Metal Particulate Matter

    Hospira is recalling 40,360 vials of Marcaine (bupivacaine hydrochloride) injection because some units contain visible metal particles that discolor the solution.

    Product
    MARCAINE — MARCAINE (BUPIVACAINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-1162-2014·2014-03-26

    Baxter Recalls 5% Dextrose Injection Due to Particulate Matter

    Baxter Healthcare is voluntarily recalling 105,216 containers of 5% Dextrose Injection due to the presence of particulate matter, including fibers and plastic particles.

    Product
    DEXTROSE — DEXTROSE (DEXTROSE MONOHYDRATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1215-2014·2014-03-26

    Biomet 3i Recalls BellaTek Zirconia Dental Abutments Due to Fracture Reports

    Biomet 3i is recalling BellaTek Zirconia Dental Abutments because of reports of fractures. The recall covers 10,454 units distributed worldwide.

    Product
    Dental Abutment labeled in part: "4555 Riverside Drive Palm Beach Gardens, FL 33410 USA 1-800-342-5454***EDAZ , EDAZx and ILDExxx***BellaTek Zirconia Abutment Position Number: XX Abutment; Pilier; Abutment; Abutment; Pilastro; Pilar***Rx only***Non-sterile, Sterilize prior to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1231-2014·2014-03-26

    Teleflex Recalls Rusch Endobronchial Tubes Due to Cuff Seal Failure

    Teleflex Medical is recalling Rusch Brochopart endobronchial tubes because the cuff may inflate to one side, preventing a proper seal of the right lung.

    Product
    Rusch Brochopart and Rusch Brochopart White The Rush Endobronchial Tube set is indicated for uses commonly associated with oral endobronchial tubes, including, but not limited to, thoracic surgery, bronchospirometry, administration of endobronchial anesthesia, etc. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1674-2014·2014-03-26

    High Mowing Organic Sprouting Seeds Recalled for Undeclared Wheat

    High Mowing Organic Seed is recalling 655 units of Organic Sprouting Seeds Ancient Eastern Blend because the product contains undeclared wheat.

    Product
    High Mowing Organic Sprouting Seeds Ancient Eastern Blend , 4 oz. resealable plastic bag UPC Code: 872724005445
    Category
    Food
    Distribution
    23 states
  • HighFDA (Devices)·Z-1213-2014·2014-03-26

    Mar Cor Purification Millenium HX Portable Reverse Osmosis System Recalled

    Mar Cor Purification is recalling 232 Millenium HX Portable Reverse Osmosis Systems due to high inlet water pressure and solenoid valve issues that could delay dialysis treatment.

    Product
    Mar Cor Purification Millenium HX Portable Reverse Osmosis System. Model 3025975. Product Usage: Water Purification System is intended to be used as a dialysis accessory to produce water through reverse osmosis for use with hemodialysis equipment..
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1216-2014·2014-03-26

    Siemens syngo Dynamics PACS Recalled for Potential Patient Data Mixup

    Siemens is recalling 50 syngo Dynamics PACS units because improper error handling could display images for one patient and reports for another, risking misdiagnosis.

    Product
    syngo Dynamics Picture Archiving and Communication System (PACS). Model numbers 10091804, 10091805, 10091806, 10091807, 10091673
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1214-2014·2014-03-26

    Alere Triage TOX Drug Screen Recalled for False Negative PCP Results

    Alere San Diego, Inc. is recalling specific lots of the Alere Triage TOX Drug Screen because they produce false negative results for PCP more often than stated in the package insert.

    Product
    Product Brand Name(s): Alere Triage¿ TOX+MTD Drug Screen, Catalog Number 94400, Lots W56013B and W56035B. 25 individually pouched devices in a labeled kit box. Indications for use: The Alere Triage¿ TOX Drug Screen is a fluorescence immunoassay to be used with the Alere…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1264-2014·2014-03-26

    Philips EPIQ 7 Ultrasound System Recalled for Incorrect Doppler Velocity Readings

    Philips is recalling EPIQ 7 Ultrasound Systems because they may report incorrect Doppler velocities when using specific settings, potentially affecting diagnostic accuracy.

    Product
    Philips Model EPIQ 7 Ultrasound System. Intended for diagnostic ultrasound imaging and fluid flow analysis. Catalogue numbers 795200 / 795201 / 795202 / 795204 / 795205 / 795206 EPIQ is intended for diagnostic ultrasound imaging and fluid flow analysis. The collection of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1234-2014·2014-03-26

    Medical Information Technology Recalls MEDITECH Microbiology Software Due to Erroneous Results

    Medical Information Technology, Inc. is recalling MEDITECH Microbiology software releases 5.6 through 6.14 because of a potential for erroneous result reporting.

    Product
    MEDITECH Microbiology; Client Server Releases 5.6, 5.65, 5.66, 5.67, 6.0, 6.05, 6.07, 6.1, 6.13 and 6.14. Integrates requisition, specimen processing, and patient information with data in the healthcare information system (HCIS).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·14141·2014-03-26

    SATCO Recalls KolourOne LED Light Bulbs Due to Injury Risk

    SATCO Products is recalling KolourOne LED light bulbs because the metal housing can separate and fall, posing a risk of injury to bystanders.

    Product
    KolourOne Brand Panel Array 2.0 and DUO 2.0 PAR LED Light Bulbs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1220-2014·2014-03-26

    Terumo Recalls Sarns Venous Return Cannulae Due to Exposed Wire

    Terumo CVS is recalling Sarns Malleable Dual-stage Venous Return Cannulae because in-process inspections found exposed basket wire on certain lots.

    Product
    Sarns Malleable Dual-stage Venous Return Cannulae, 32/40 Fr with 1/2" connector, 15" (38 cm) long The Sarns Malleable Dual-stage Venous Return Catheters and Sarns Dual-stage Venous Return Cannula are indicated for single-tube venous drainage from the right atrium and vena…
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-1218-2014·2014-03-26

    Terumo Recalls Sarns Venous Return Cannulae Due to Exposed Wire

    Terumo CVS is recalling Sarns Malleable Dual-stage Venous Return Cannulae because in-process inspections found exposed basket wire on certain lots.

    Product
    Sarns Malleable Dual-stage Venous Return Cannulae, 28/38 Fr with 1/2" connector, 14.5" (37 cm) long The Sarns Malleable Dual-stage Venous Return Catheters and Sarns Dual-stage Venous Return Cannula are indicated for single-tube venous drainage from the right atrium and vena…
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-1224-2014·2014-03-26

    Terumo Recalls Sarns Dual-stage Venous Return Cannulae Due to Exposed Wire

    Terumo CVS is recalling Sarns Dual-stage Venous Return Cannulae because in-process inspections found exposed basket wire on certain lots.

    Product
    Sarns Dual-stage Venous Return Cannulae, 34/46 Fr with 1/2" flare The Sarns Malleable Dual-stage Venous Return Catheters and Sarns Dual-stage Venous Return Cannula are indicated for single-tube venous drainage from the right atrium and vena cava during cardiopulmonary bypass…
    Category
    Medical Device
    Distribution
    15 states
  • HighUSDA FSIS·pha-032614·2014-03-26

    USDA Issues Public Health Alert for Nutriom Egg Products Unfit for Consumption

    USDA FSIS issued a public health alert for Nutriom LLC egg products because the company refused to expand a recall of items found to be unfit for human consumption due to falsified lab results.

    Product
    FSIS Issues Public Health Alert For Egg Products Unfit For Human Consumption
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1232-2014·2014-03-26

    Philips Recalls HeartStart Home and OnSite AEDs Due to Solder Residue

    Philips is recalling HeartStart Home and OnSite AEDs because solder residue may prevent the device from delivering therapy in an emergency.

    Product
    Philips HeartStart Home and OnSite (HS1) automated external defibrillators (AEDs). Product Usage: The models M5066A, M5067A, and M5068A are designed for use on a person in sudden cardiac arrest who is: -Unresponsive when shaken -Not breathing normally If in doubt, apply the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1064-2014·2014-03-26

    Elekta Linear Accelerators Recalled for Default Value Reset Issues

    Elekta, Inc. is recalling SL & SLi Series linear accelerators because customers are resetting default values outside recommended factory settings.

    Product
    SL & SLi Series (Mod 15/18/20/25) Linear Accelerator Used for radiation therapy treatments of malignant neoplastics diseases.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1266-2014·2014-03-26

    Otto Bock Recalls Aerial Wheelchair Cushions Due to Flammability Risk

    Otto Bock is recalling Aerial and Aerial Active wheelchair cushions because internal testing found a small risk of flammability after high-temperature washing.

    Product
    Otto Bock Aerial and Aerial Active Wheelchair Cushions. Material numbers: SK757 476C00=SK701, 476C00=SK702, 476C00=SK703, 476C00=SK704, 476C00=SK705, 476C00=SK706, 476C00=SK707, The following material numbers were not distributed within the US: 476C00=SK751, 476C00=SK752…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1222-2014·2014-03-26

    Terumo Recalls Sarns Venous Return Cannulae Due to Exposed Wire

    Terumo CVS is recalling Sarns Malleable Dual-stage Venous Return Cannulae because in-process inspections found exposed basket wire on certain lots.

    Product
    Sarns Malleable Dual-stage Venous Return Cannulae, 34/46 Fr with 1/2" connector, 15" (38 cm) long, with X Coating The Sarns Malleable Dual-stage Venous Return Catheters and Sarns Dual-stage Venous Return Cannula are indicated for single-tube venous drainage from the right…
    Category
    Medical Device
    Distribution
    15 states