The Recall Desk

State

Tennessee product recalls

73,885 recalls have nationwide distribution and so reach Tennessee. 7,863 additional recalls listed Tennessee specifically in their distribution scope.

What the numbers show

Total
7,863
Critical
1,324
Severe
1,975
Most recent
2026-11-14

Of the 7,863 recalls naming Tennessee we have scored against our rubric, 1,324 (17%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,975 (25%) are Severe.

These figures cover only the 7,863 recalls whose distribution notice names Tennessee specifically. The 73,885 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

64601–64625 of 81748

  • SevereNHTSA·14V393000·2014-07-02

    Ford and Lincoln Recall Vehicles for Halfshaft Retention Defect

    Ford is recalling 2012-2014 Edge, MKX, Taurus, MKS, Flex, and MKT vehicles because a halfshaft may disengage, causing loss of power or vehicle roll-away.

    Product
    LINCOLN — LINCOLN, FORD MKS, FLEX, EDGE, TAURUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1854-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks used with the PureFlow SL system because they contain aluminum levels exceeding internal specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-301 Lactate 45, Potassium 1, Sodium 140, Calcium 3, Magnesium 1, Chloride 100, Glucose (mg/dL) 100 Batch Size (liters) 60 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1925-2014·2014-07-02

    Biomet Recalls Discovery Elbow Prosthesis Due to Surface Finish Defect

    Biomet, Inc. is recalling one unit of a Discovery Elbow prosthesis because the surface finish differs from specifications, potentially causing pain requiring surgery.

    Product
    DISCOVERY ELBOW prosthesis, 4 MM X 100 MM RIGHT HUMERAL FLANGED I BOND COAT Tl 6AL 4V ALLOY. Elbow joint replacement prostheses are intended for primary and revision joint arthroplasty for use in cemented applications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V409000·2014-07-02

    GM Recalls 2014 Vehicles for Steering Component Separation Risk

    General Motors is recalling 2014 Buick Regal, Cadillac XTS, Chevrolet Camaro, and Chevrolet Impala vehicles because improperly torqued fasteners may cause steering components to separate, increasing crash risk.

    Product
    CHEVROLET — CHEVROLET, BUICK, CADILLAC IMPALA, CAMARO, REGAL, XTS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V401000·2014-07-02

    Ford Recalls F-59 Commercial Chassis Vehicles for Fire Risk

    Ford is recalling 2011-2014 F-59 commercial chassis vehicles because a short circuit in the electrical system may cause a fire.

    Product
    FORD — FORD F-59
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·14V392000·2014-07-02

    Chrysler Recalls 2014-2015 Vehicles for Rear Shock Absorber Weld Defect

    Chrysler is recalling 2014 Jeep Cherokee, Ram 1500, and 2015 Chrysler 200 vehicles because an insufficient weld may cause rear shocks to detach, potentially damaging tires or reducing braking.

    Product
    CHRYSLER — CHRYSLER, RAM, JEEP 200, 1500, CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·14V456000·2014-07-02

    Sutphen Minitower Fire Truck Seat Belt Buckle Recall

    Sutphen is recalling one 2013 Minitower fire truck because seat belt buckles may fail to release, potentially hindering emergency egress.

    Product
    SUTPHEN — SUTPHEN MINITOWER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1874-2014·2014-07-02

    Zynex IF 8000 Interferential Electrical Stimulation Device Recalled for Overheating

    Zynex Medical is recalling 1,461 IF 8000 devices because a malfunction can cause them to stop working or overheat, posing a burn risk.

    Product
    IF 8000; 1/F Interferential Electrical Stimulation Device; NMES (neuromuscular electrical stimulation) mode. Designed for use in physical therapy, rehabilitation, and pain relief applications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1859-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling 2,711 cases of dialysate sacks because aluminum levels exceeded internal specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-306 Lactate 45, Potassium 2, Sodium 140, Calcium 3, Magnesium 1, Chloride 101, Glucose (mg/dL) 100 Batch Size (liters) 50 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1409-2014·2014-07-02

    Pfizer Recalls Pristiq 50 mg Tablets Due to Foreign 100 mg Tablet

    Pfizer is recalling Pristiq 50 mg extended-release tablets because a 100 mg tablet was found in a bottle labeled for 50 mg.

    Product
    PRISTIQ — PRISTIQ (DESVENLAFAXINE SUCCINATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1927-2014·2014-07-02

    Siemens Healthcare Recalls ADVIA Acid/Base Reagent Kits Due to Metal Contamination

    Siemens Healthcare is recalling ADVIA Acid/Base Reagent 1 and 2 Kits because trace metal contamination caused the acid bottles to swell.

    Product
    Siemens Healthcare ADVIA Acid/Base Reagent 1 and 2 Kit containing ADVIA Centaur Acid Reagent bottles, lot number: 454778 Kit Catalog Number: 112219 SMN: 10310026 Intended Use: In vitro diagnostic use. Acid Regent is a component of the ADVIA Centaur and ADVIA Centaur XP…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1867-2014·2014-07-02

    Siemens StreamLAB Analytical Workcell Recalled for Trip and Fall Hazard

    Siemens is recalling 317 StreamLAB Analytical Workcells because protruding pins on the Input/Output Module have contributed to trip and fall incidents.

    Product
    Siemens StreamLAB(R) Analytical Workcell; Catalog number 746002.901. Designed to automate sample handling and processing in the clinical laboratory.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·14V417000·2014-07-02

    GM Recalls 2012-2014 Vehicles for Damaged Block Heater Cords

    General Motors is recalling specific 2012-2014 Buick and Chevrolet vehicles because insulation on the engine block heater cord can damage in cold weather, exposing wires.

    Product
    CHEVROLET — CHEVROLET, BUICK SONIC, VERANO, CRUZE, ENCORE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1857-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks with concentrate due to aluminum levels exceeding internal product specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-304 Lactate 45, Potassium 2, Sodium 140, Calcium 3,Magnesium 1, Chloride 101, Glucose (mg/dL) 100 Batch Size (liters) 60 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1869-2014·2014-07-02

    Elekta MOSAIQ Oncology System Recalled for Dose Calculation Error

    Elekta, Inc. is recalling MOSAIQ oncology information system software because it fails to recalculate agent volume when users change the ordering dose.

    Product
    MOSAIQ MOSAIQ is an oncology information system used to manage workflows for treatment planning and delivery. It supports information flow among healthcare facility personnel and can be used where ever radiotherapy and/or chemotherapy are prescribed.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1858-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks with concentrate due to aluminum levels exceeding internal product specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-305 Lactate 45, Potassium 1, Sodium 140, Calcium 3, Magnesium 1 Chloride 100, Glucose (mg/dL) 100 Batch Size (liters) 40
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1844-2014·2014-07-02

    Puritan Bennett 840 Ventilator Recall for Display Loss

    Nellcor Puritan Bennett is recalling 104 Puritan Bennett 840 Ventilators due to reports of loss of graphical user interface display information while the device continues to provide breath support.

    Product
    Puritan Bennett 840 Ventilator (4-840120DIUU-XX) The PB840 Ventilator System is intended to provide invasive or non-invasive ventilatory support and monitoring for infant, pediatric, and adult patients with respiratory failure or respiratory insufficiency. It is used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1841-2014·2014-07-02

    SeaSpine Recalls UCR 3mm Hex Large Axial Driver Due to Tip Deformation

    SeaSpine Inc is recalling seven units of the UCR 3mm Hex, Large Axial Driver because the tip may twist or become rounded during use.

    Product
    Integra UCR 3mm Hex, Large Axial Driver. The UCR Hex Axial Driver is a surgical instrument used to implant and remove polyaxial screws of varying reduction heights provided with the Malibu", UCR, and NewPort" Systems. The Malibu", UCR, NewPort" Systems are intended to be used…
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-1848-2014·2014-07-02

    SteriGear Recalls Urinary Drain Bags Due to Valve Malfunction

    SteriGear is recalling 110,560 urinary drain bags because the valve can close and create negative pressure, potentially blocking urine flow.

    Product
    SteriGear Urinary Drain Bag with Fig Leaf Cover, 2000 ml, REF 10270, The Fig Leaf, SteriGear 362 S. University Avenue, provo, UT 84601, 1-800-398-3259, SteriGear.com, Sterile, EO Urinary Drainage Collection Kit, for Indwelling Catheter. This device is intended to collect the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1849-2014·2014-07-02

    Western VIPR Pressure Regulators Recalled for Cylinder Separation Risk

    Western / Scott Fetzer Company is recalling Model RG3000 and RG4000 Series Valve Integrated Pressure Regulators (VIPR) because they may separate from aluminum cylinders.

    Product
    Model RG3000 and RG4000 Series Valve Integrated Pressure Regulator (VIPR)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1873-2014·2014-07-02

    JAS Diagnostics Recalls Glucose Hexokinase Reagent Lots for Performance Issues

    JAS Diagnostics Inc. is recalling specific lots of Glucose Hexokinase Liquid Reagent because they do not perform according to specifications.

    Product
    Glucose Hexokinase Liquid Reagent For the in vitro quantitative determination of Glucose in serum.
    Category
    Medical Device
    Distribution
    17 states
  • ModerateFDA (Devices)·Z-1926-2014·2014-07-02

    Siemens Dimension LOCI Troponin I Calibrator Recalled for Result Shifts

    Siemens is recalling Dimension LOCI Troponin I Calibrators because they may cause a 24% upward shift in test results.

    Product
    Siemens Dimension LOCI TNI Troponin I Calibrator RC 621. The LOCI TNI Troponin I Calibrator is an in vitro diagnostic product for the calibration of the cardiac troponin I (TNI) method for the Dimension clinical EXL integrated chemistry system with LOCI module.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1917-2014·2014-07-02

    Anspach Custom Devices Recalled for Quality System Non-Compliance

    The Anspach Effort, Inc. is recalling Anspach Custom Devices because they were not manufactured consistently with Quality System requirements.

    Product
    ANSPACH***REF SP-5001-00***20 degree Angle Driver (MA-D20) - Custom***Rx Only*** This device is intended to be used with Anspach Systems
    Category
    Medical Device
    Distribution
    14 states