  • HighFDA (Devices)·Z-0486-2026·2025-11-19

    VATS lobectomy stapler boxes recalled over a malformed cover tube press

    Covidien is recalling two units of a VATS lobectomy box containing the Signia Small Diameter Curved Tip Intelligent Reload because internal components may move during firing.

    Product
    Covidien Signia" Small Diameter Curved Tip Intelligent Reload (45mm Vascular/Thin); BOX LOBECTOMIA VATS 3D; CFN: BOX06170V4;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0182-2026·2025-11-19

    Dietary supplement recalled because it contains magnesium salicylate

    Professional Botanicals is recalling 430 bottles of Total Comfort capsules because the product contains magnesium salicylate.

    Product
    Product Name: Total Comfort. Package: 175cc HDPE Bottle. Type: Vegetable Capsule Count: 60, Dose: 2 Capsules. Product Sku: PB173.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0454-2026·2025-11-19

    CARESCAPE ONE monitors recalled over batteries that fail to hold charge

    GE Healthcare is recalling 5,935 CARESCAPE ONE patient monitors because certain batteries can lose the ability to hold charge, causing a loss of patient monitoring.

    Product
    CARESCAPE ONE, Model no. 2087075-300 - shipped with potentially affected batteries or affected batteries installed as a spare part Monitor, Physiological, Patient (With Arrhythmia Detection or Alarms Updated 3/19 to add CARESCAPE ONE MBZ101 2087075-001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0476-2026·2025-11-19

    Reprocessed vessel sealers recalled over residual material that may dislodge

    Medline is recalling 57,244 reprocessed LigaSure Maryland Jaw sealer/dividers because certain areas of the device can trap residual material that may, in rare cases, become dislodged.

    Product
    Medline Renewal LigaSure Maryland Jaw Sealer/Divider NanoCoated, Compatible w/FT10 37 cm FT10 SW Version 4.0.1.15 or lower; Electrosurgical, Cutting & Coagulation Accessories, Laparoscopic & Endoscopic, Reprocessed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0457-2026·2025-11-19

    Monitor batteries recalled because they can lose the ability to charge

    GE Healthcare is recalling 2,857 FLEX-3S2P lithium-ion batteries used with patient monitors because they can lose the capability to hold charge and provide backup power.

    Product
    BATTERY FLEX-3S2P 10.8V 18650 LI-ION SMBUS used with affected patient monitors Model No 2062895-001 Manufacturer Part Number U80296-1R01, revision S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0493-2026·2025-11-19

    Food allergen panels recalled over barcodes causing wrong tube scanning order

    Siemens Healthcare Diagnostics is recalling 28 units of Food Panel 3 Specific Allergen because barcode orientation causes the instrument to misread tube positions in the holder wedge.

    Product
    Food Panel 3 Specific Allergen; Siemens Material Number (SMN): 10385891; Catalog Number: FP3L4;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0452-2026·2025-11-19

    Lithotripsy transducers recalled over startup failures and handpiece temperature rise

    Olympus is recalling 1,528 ShockPulse Lithotripsy Transducers because the device may fail to start or stop shortly after starting, and the handpiece body may heat up during clinical use.

    Product
    Brand Name: Lithotriptor, Ultrasonic Product Name: ShockPulse Lithotripsy Transducer Model/Catalog Number: SPL-T Product Description: The ShockPulse Lithotripsy System is an electromechanical device capable of fragmenting calculi and aspirating stone debris. The ShockPulse tra
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0181-2026·2025-11-19

    Nutra Calm supplement recalled because it contains magnesium salicylate

    Professional Botanicals is recalling 452 bottles of Nutra Calm capsules because the product contains magnesium salicylate.

    Product
    Product Name: Nutra Calm Package: 175cc HDPE Bottle. Type: Vegetable Capsule Count: 90, Dose: 2 Capsules. Product Sku: PB248
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0498-2026·2025-11-19

    Long nasal feeding tubes recalled from one lot for possible occlusion

    Applied Medical Technology is recalling NutraGlide 6 F-8 F x 90 nasal feeding tubes with stylet and ENfit from one lot because the tube may be occluded.

    Product
    Applied Medical Technology, Inc., NutraGlide, 6 F- 8 F x 90 Nasal Feeding Tube with Stylet and ENfit, REF NFT-06090-I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0499-2026·2025-11-19

    Ceiling X-ray tube supports recalled over a shaft that may break

    Shimadzu is recalling 1,766 ceiling type X-ray tube supports, models CH-200 and CH-200M, because the mounting shaft may break and the tube assembly could come off.

    Product
    Ceiling Type X-Ray Tube Support Models CH-200 and CH-200M used with RADspeed, SonialVision and FLUOROspeed Systems The ceiling type x-ray tube support CH-200 is used to hold the X-ray tube and collimator to position the X-ray tube unit. This unit is used for radiographic ex
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V800000·2025-11-19

    McNeilus Recalls 2024-2025 Volterra ZSL Trucks Due to Software Error

    McNeilus is recalling 2024-2025 Volterra ZSL side loader garbage trucks because a software error may cause grabber fingers to move without operator input, posing a risk of injury or crash.

    Product
    MCNEILUS — MCNEILUS VOLTERRA ZSL
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0483-2026·2025-11-19

    Fifteen millimetre snares recalled over holes compromising package sterility

    Olympus is recalling 18,174 Single Use Electrosurgical Snares SD-400U-15 because sterility may be compromised by small holes formed during packaging or transportation.

    Product
    Brand Name: Olympus Single Use Single Use Electrosurgical Snare SD-400 Product Name: Single Use Single Use Electrosurgical Snare Model/Catalog Number: SD-U400U-15 Product Description: These instruments have been designed to be used with an Olympus endoscope for the removal and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0470-2026·2025-11-19

    Small jaw sealers recalled over residual material that may dislodge

    Medline is recalling 18,117 reprocessed LigaSure Small Jaw instruments because certain areas of the device can trap residual material that may become dislodged.

    Product
    Medline Renewal LigaSure Small Jaw Instrument (Purple/White), Compatible with FT10 Generator 18.8 cm FT10 SW Version 4.0.1.15 or lower; Electrosurgical, Cutting & Coagulation Accessories, Laparoscopic & Endoscopic, Reprocessed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0494-2026·2025-11-19

    Nasal feeding tubes recalled from a second lot for possible occlusion

    Applied Medical Technology is recalling NutraGlide 5 F-6 F x 55 nasal feeding tubes with stylet and ENfit, REF NFT-05055-I, from one lot because the tube may be occluded.

    Product
    Applied Medical Technology, Inc., NutraGlide, 5 f - 6F x 55 Nasal Feeding Tube with Stylet and ENfit, REF NFT-05055-I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0466-2026·2025-11-19

    Radiography systems recalled over ceiling carriages that are hard to move

    Philips is recalling 284 Radiography 7300 C systems because some ceiling suspension telescopic carriages may be difficult to move vertically.

    Product
    Radiography 7300 C; Model Number: 712037;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0464-2026·2025-11-19

    DigitalDiagnost 4 systems recalled over ceiling carriages hard to move

    Philips is recalling 12 DigitalDiagnost 4 systems because some ceiling suspension telescopic carriages may be difficult to move vertically.

    Product
    DigitalDiagnost 4 (1) High Performance, (2) Flex/Value; Model Number: (1) 712031, (2) 712032;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0500-2026·2025-11-19

    Platelet reactivity tests recalled after an uncleared device was distributed

    Accriva Diagnostics is recalling 125 boxes, 3,125 tests, of VerifyNow PRUTest because a device without premarket clearance was incorrectly packaged and distributed.

    Product
    VerifyNow PRUTest Platelet Reactivity Test REF 85225 UDI-DI code: 10711234150078 The VerifyNow PRUTest is a whole blood test used in the laboratory or point of care setting to measure the level of platelet P2Y12 receptor blockade.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0465-2026·2025-11-19

    DigitalDiagnost C90 systems recalled over ceiling carriages resisting vertical movement

    Philips is recalling 223 DigitalDiagnost C90 systems because some ceiling suspension telescopic carriages may be difficult to move vertically.

    Product
    DigitalDiagnost C90 (1) High Performance, (2) Flex/Value/Chest/ER; Model Number: (1) 712034, (2) 712035;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0484-2026·2025-11-19

    Laboratory cuvette arrays recalled over barcodes the analyser cannot read

    Becton Dickinson is recalling 29,760 BD Kiestra Isolate Suspension Cuvette Arrays because formatting errors in the 2D barcodes stop the analyser reading the expiration date.

    Product
    BD Kiestra" Isolate Suspension Cuvette Array; Catalog No.: 246100;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0479-2026·2025-11-19

    ACL restoration implants recalled from one lot held in sales stock

    Miach Orthopaedics is recalling 167 BEAR Implants from a single lot, in an action the record says was limited to sales force trunk stock.

    Product
    BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E078000·2025-11-18

    Mack Trucks Recalls Certain Vehicles Due to Electronic Control Unit Defect

    Mack Trucks is recalling certain vehicles because electrical noise may cause the electronic control unit to malfunction, potentially disabling safety systems like ABS and increasing crash risk.

    Product
    SERVICE BRAKES, AIR:ANTILOCK:CONTROL UNIT/MODULE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25E077000·2025-11-18

    Volvo Trucks Recalls Bendix EC80 Electronic Control Units for Software Defect

    Volvo Trucks is recalling certain Bendix EC80 Advanced Electronic Control Units due to a software defect that may cause safety systems to fail, increasing crash risk.

    Product
    SERVICE BRAKES, AIR:ANTILOCK:CONTROL UNIT/MODULE recall
    Category
    Vehicle
    Distribution
    Distributed nationwide