The Recall Desk

State

New York product recalls

73,474 recalls have nationwide distribution and so reach New York. 12,945 additional recalls listed New York specifically in their distribution scope.

What the numbers show

Total
12,945
Critical
1,511
Severe
3,698
Most recent
2026-10-14

Of the 12,945 recalls naming New York we have scored against our rubric, 1,511 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 3,698 (29%) are Severe.

These figures cover only the 12,945 recalls whose distribution notice names New York specifically. The 73,474 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

21951–21975 of 86419

  • ModerateFDA (Devices)·Z-1787-2022·2022-10-05

    Saline wound flush recalled due to temperature exposure affecting effectiveness

    Mckesson is recalling SafeWash Saline Wound Flush due to temperature exposure that may have reduced product effectiveness. The recall affects units distributed nationwide from June through September 2021.

    Product
    DERMARITE INDUSTRIES SafeWash Saline Saline Wound Flush SafeWash 7.1 oz. Can Sterile 0.9% Sodium Chloride Model Number: 00245
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1791-2022·2022-10-05

    Sterilization Roll Recalled Due to Temperature Exposure During Manufacturing

    SPS Medical Supply Crosstex sterilization rolls (model SCT3) are being recalled because they were exposed to high temperatures during manufacturing facility storage before shipment. Temperature exposure may have compromised the product's sterilization effectiveness.

    Product
    SPS MEDICAL SUPPLY Crosstex International Sterilization Roll Sani-Roll Ethylene Oxide (EO) Gas / Steam 3 Inch X 100 Foot Transparent / Blue Self Seal Paper / Film Model Number: SCT3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1800-2022·2022-10-05

    Wound Care Dressings Recalled Due to Temperature Exposure

    Mckesson is recalling Shur-Conform and ALGICELL wound care dressings due to temperature exposure affecting product effectiveness. All affected units were distributed June through September 2021.

    Product
    a. INTEGRA LIFESCIENCE (WND CARE) Shur-Conform Oil Emulsion Oil Emulsion Impregnated Dressing Shur-Conform 3 X 8 Inch Knitted Cellulose Acetate Petrolatum Emulsion Sterile Model Number: 77042. b. INTEGRA LIFESCIENCE (WND CARE) ALGICELL Ag Silver Alginate Dressing Algicell…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0004-2023·2022-10-05

    Esomeprazole Magnesium Capsules Recalled for Out-of-Specification Potency

    Sun Pharmaceutical is recalling Esomeprazole Magnesium Delayed-Release Capsules, USP 20mg nationwide due to superpotency findings. Lot AC14299 (expiration 12/2022) tested out of specification for drug assay at the 12-month stability timepoint.

    Product
    ESOMEPRAZOLE MAGNESIUM — ESOMEPRAZOLE MAGNESIUM (ESOMEPRAZOLE MAGNESIUM)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1793-2022·2022-10-05

    STERIS Sterilization Indicators Recalled Due to Temperature Excursions

    Six sterilization monitoring devices from STERIS Corporation were recalled due to temperature excursions during storage and delivery that may have compromised their effectiveness. Affected products were distributed nationwide between June and September 2021.

    Product
    a. STERIS CORP Celerity Celerity 20 Sterilization Indicator Challenge Pack Steam 3 Inch Length Model Number: LCB053. b. STERIS CORP VERIFY Verify SixCess Sterilization Flash Indicator Strip Steam 2-3/4 Inch Model Number: PCC006. c. STERIS CORP VERIFY Verify Sterilization…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1789-2022·2022-10-05

    Collagen Powder Recalled Due to Temperature Exposure During Shipment

    DermaCol 100 Collagen Powder was exposed to higher temperatures during storage from June to August 2021. The product's effectiveness may have been impacted, though the FDA determined no adverse health consequences are likely.

    Product
    DERMARITE INDUSTRIES DermaCol 100 Collagen Powder DermaCol 100 Collagen 1 Gram Model Number: 00300E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1542-2022·2022-10-05

    Ampicillin for Injection Recalled Due to Foreign Object Contamination

    Viatris Inc recalls 3,931 cartons of Ampicillin for Injection after a complaint of a hair strand found in one vial. No illnesses have been reported.

    Product
    Ampicillin for Injection, USP, 2 grams/vial NDC 67457-352-02, packaged in 10 x 2 g vials per carton NDC 67457-352-10, Rx only, Mylan Manufactured in India for: Mylan Institutional LLC Rockford, IL 61103 U.S.A
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1790-2022·2022-10-05

    SporView Sterilization Biological Indicator Kit Recalled for Temperature Exposure

    McKesson is recalling SporView Culture Set biological indicator kits (models CS-020 and CS-100) due to facility temperature excursions that may have compromised product effectiveness. Affected units were distributed nationwide between June and September 2021.

    Product
    a. SporView Culture Set SporView Sterilization Biological Indicator Kit Steam / EO Gas / Dry Heat / Chemical Vapor Model Number: CS-020 b. SPORVIEW CULTURE SET SporView Sterilization Biological Indicator Kit Steam / EO Gas / Dry Heat / Chemical Vapor Model Number: CS-100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1778-2022·2022-10-05

    Incompatible tibial bearing supplied for knee prosthesis installation

    An MK4 tibial bearing knee implant component was mistakenly supplied when an MK3 model was required. The mismatch was discovered during surgery and corrected by the surgeon.

    Product
    Short tibial bearing MK4 - Std, STM, Catalog No. SMMLTB02. Knee prosthesis component.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1805-2022·2022-10-05

    McKesson Calcium Alginate Wound Dressings Recalled for Temperature Exposure During Storage

    McKesson Medical-Surgical is recalling multiple calcium alginate wound dressings due to facility temperature excursions that may have impacted product effectiveness. The FDA states the affected products are not likely to cause adverse health consequences.

    Product
    a. ADVANCED MEDICAL SOLUTIONS McKesson DRESSING, CALCIUM ALGINATE SHEET 4"X8" (5/BX 10BX/CS), Catalog #3563. b. ADVANCED MEDICAL SOLUTIONS McKesson DRESSING, CALCIUM ALGINATE AG2X2" (10/BX 10BX/CS) Catalog #3557. c. ADVANCED MEDICAL SOLUTIONS McKesson DRESSING, CALCIUM…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1799-2022·2022-10-05

    Surgitube Surgical Bandages Recalled for Temperature Exposure During Storage

    McKesson is recalling Surgitube surgical bandages distributed between June and September 2021 that may have been exposed to elevated temperatures during storage. The FDA states the temperature exposure is unlikely to cause adverse health effects.

    Product
    a. DERMA SCIENCES, INC Surgitube BANDAGE, GAUZE SURGI WHT SZ15/8" 50YDS Catalog #GL-219. b. DERMA SCIENCES, INC Surgitube BANDAGE, GAUZE SURGI WHT SZ2 1" 50YDS Catalog # GL-220. c. DERMA SCIENCES, INC Surgitube BANDAGE, GAUZE SURGI WHT SZ4 25/8" 50YDS Catalog # GL-222. d.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1817-2022·2022-10-05

    Starling Monitor Devices Recalled for Incorrect Device Identification Labeling

    Baxter Healthcare is recalling Starling Monitor devices and accessories due to incorrect Unique Device Identification (UDI) information on labels and non-compliant barcodes. Approximately 9,671 units distributed nationwide are affected.

    Product
    Starling Monitor, Product code CMMST5 and Starling Monitor SV, Product code CMM-ST5 (same products); and accessories/spare parts Starling Battery Pack, Product Code CMABATT; and Starling Patient Cable, Product code CMASC10.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1807-2022·2022-10-05

    Wound Dressing Units Recalled Due to Storage Temperature Excursions

    KerraCel Ag wound dressing units distributed between June and September 2021 are being recalled due to facility temperature excursions that may have affected product effectiveness. The FDA states no adverse health consequences are likely.

    Product
    3M SYSTAGENIX/KCI KerraCel Ag DRESSING, WOUND KERRACEL AG 4X5 (10/CT 10CT/CS) Catalog #CWL1158
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1806-2022·2022-10-05

    McKesson Wound Dressing Products Recalled for Temperature Exposure

    McKesson wound dressing products distributed nationwide are being recalled due to exposure to elevated temperatures during storage that may have reduced their effectiveness. No adverse health consequences have been reported.

    Product
    a. ADVANCED MEDICAL SOLUTIONS McKesson DRESSING, WOUND GELLING FIBERHIGH-ABSRB 4"X4 3/4" (10/BX) Catalog #87400. b. ADVANCED MEDICAL SOLUTIONS McKesson DRESSING, WND GELLING FIBER HIABSRB AG 4X4.75 (10/BX 10BX/CS Catalog #177400. c. ADVANCED MEDICAL SOLUTIONS McKesson…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1851-2022·2022-10-05

    Leica Surgical Microscopes: Photodiode Defect Causes Inaccurate Illumination

    Leica Microsystems is recalling 32 surgical operating microscopes due to a photodiode component defect that produces inaccurate illumination adjustment when BrightCare Plus with Luxmeter is used.

    Product
    Leica Surgical Operating Microscopes, PROvido Part Numbers: a. 10448976, b. 10448950
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1802-2022·2022-10-05

    Medical Monofilament Testing Devices Recalled for Temperature Excursion

    Mckesson Medical-Surgical is recalling monofilament sensory testing devices (13 units) due to temperature excursions during June-August 2021. Heat exposure may have compromised device effectiveness.

    Product
    Medical Monofilament Manufacturing MONOFILIMENT TEST, SENSORY F/FOOT 10GM (40/PK) Model Number: AM140
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1798-2022·2022-10-05

    AquaGuard Wound Dressing Recall Due to Facility Temperature Excursions

    TIDI Products AquaGuard wound dressings received June–September 2021 were exposed to elevated storage temperatures that may have impacted product effectiveness. The FDA states adverse health consequences are unlikely.

    Product
    a. TIDI PRODUCTS, LLC AquaGuard DRESSING, AQUA GUARD MOISTR 7X7 (5/PK) 9CENCO Catalog #68751510104. b. TIDI PRODUCTS, LLC AquaGuard DRESSING, AQUA GUARD MOISTR BARR 10X12 (5/BX) Catalog #68751510105
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1796-2022·2022-10-05

    Mckesson DermaCol Collagen Dressings Recalled for Storage Temperature Excursion

    Mckesson recalls DermaCol collagen dressings exposed to temperature excursions during storage (June-August 2021). FDA stated adverse health consequences are unlikely.

    Product
    a. DERMARITE INDUSTRIES DermaCol Collagen Dressing DermaCol Without Border Collagen / Sodium Alginate / Carboxyl Methylcellulose (CMC) / Ethylenediamine-tetraacetic Acid (EDTA) 4 X 4 Inch 10 Count Model Number: 00303E. b. DERMARITE INDUSTRIES DermaCol Ag Silver Collagen…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V738000·2022-10-04

    Contract Manufacturer Recalls 2023 Trailers With Incorrect Axle Size

    Contract Manufacturer is recalling 2023 trailers because an incorrect axle size may have been installed, posing a crash risk if the axle breaks.

    Product
    CONTRACT MANUFACTURER — CONTRACT MANUFACTURER EQ14-17+3, TH10-20BK4CR, EQ16-17+3, TU10-20BK4CR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V736000·2022-10-04

    Blue Bird Recalls 2013-2021 Vision School Buses for Fuel Leak Risk

    Blue Bird is recalling 2013-2021 Vision school buses with Ford 6.8L LPG engines because a damaged fuel line may leak, increasing fire risk.

    Product
    BLUE BIRD — BLUE BIRD VISION, VISION SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V737000·2022-10-04

    2022-2023 Coachmen Recreational Vehicles Recall: Unintended Awning Movement

    Forest River is recalling certain 2022-2023 Coachmen recreational vehicles with a software issue that may cause the awning to unintentionally extend or retract while parked, increasing injury risk. Owners should contact dealers for a free ECM software update.

    Product
    COACHMEN — COACHMEN GALLERIA, NOVA, BEYOND
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V735000·2022-10-03

    East Texas Recalls 2021 Tank Trailers Due to Axle Weld Defect

    East Texas Trailer is recalling 2021 Tank trailers because a defective axle weld may crack or separate, increasing crash risk.

    Product
    EAST TEXAS — EAST TEXAS TANK TRAILER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22E085000·2022-09-30

    Meritor Recalls Front Non-Drive Steer Axles Due to Tie Rod Clamp Cracking

    Meritor is recalling certain Front Non-Drive Steer Axles because improperly heat-treated tie rod clamps may crack and separate, potentially causing a sudden loss of steering.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V734000·2022-09-30

    Great Dane Recalls 2023 Trailers Due to Brake Pad Retaining Clip Issue

    Great Dane is recalling 2023 Champion and Everest trailers because a loose brake pad retaining clip may reduce braking performance or cause a flat tire.

    Product
    GREAT DANE — GREAT DANE EVEREST, CHAMPION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V751000·2022-09-30

    Braun Ambulances Recall 2018-2022 Models Due to Rear Door Bolt Issue

    Braun Ambulances is recalling 2018-2022 models because rear door striker bolts may dislodge, potentially causing the door to open during a crash.

    Product
    BRAUN AMBULANCES — BRAUN AMBULANCES SUPER CHIEF, EXPRESS PLUS, LIBERTY, TLC
    Category
    Vehicle
    Distribution
    Distributed nationwide