The Recall Desk

State

New Jersey product recalls

73,509 recalls have nationwide distribution and so reach New Jersey. 9,773 additional recalls listed New Jersey specifically in their distribution scope.

What the numbers show

Total
9,773
Critical
1,249
Severe
2,939
Most recent
2026-10-14

Of the 9,773 recalls naming New Jersey we have scored against our rubric, 1,249 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,939 (30%) are Severe.

These figures cover only the 9,773 recalls whose distribution notice names New Jersey specifically. The 73,509 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

24676–24700 of 83282

  • HighCPSC·22731·2022-02-24

    Kelly Wynne Children's Handbags Recalled for Excess Lead Content

    Kelly Wynne is recalling about 1,050 Mama & Me MINI children's handbags sold online from July 2020 through October 2021 because metal components contain lead levels that exceed the federal ban. No injuries have been reported.

    Product
    Mama & Me MINI Children's Handbags
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·22V110000·2022-02-24

    Yamaha Recalls 2021 Tracer 9 GT Motorcycles Due to Throttle Grip Defect

    Yamaha is recalling 453 2021 Tracer 9 GT motorcycles because the throttle grip may break if used to lift the bike, potentially causing loss of throttle control and a crash.

    Product
    YAMAHA — YAMAHA TRACER 9 GT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·22V111000·2022-02-24

    Missing Mounting Bolt in 2022 INFINITI QX60 Second-Row Seat Track

    Nissan is recalling 2022 INFINITI QX60 vehicles because the second-row seat track may be missing a mounting bolt. This could allow the seat track to move during a crash, increasing injury risk.

    Product
    NISSAN — NISSAN, INFINITI PATHFINDER, QX60
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-0648-2022·2022-02-23

    HCG 6,000iu Injection Recalled for Bacterial Contamination

    Revive Rx is recalling HCG 6,000iu injectable medication due to bacterial contamination (Paenibacillus lautus) identified in the product. The affected lot was distributed nationwide.

    Product
    HCG 6,000iu (lyo) Human Chorionic Gonadotropin Inj., For Sub-Q or IM Use Only, Not For IV Use, Vial, Rx Only, Compounded By: Revive Rx 3831 Golf Dr., Houston, TX 77018, NDC: 88888-1739-01.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0638-2022·2022-02-23

    RED MAMMOTH 400 mg Capsules Recalled for Undeclared Active Pharmaceutical Ingredients

    RED MAMMOTH capsules, 400 mg (Lot # DK1027, Exp. 08/01/2023) are being recalled because they contain undeclared sildenafil and tadalafil, making them an unapproved drug marketed without FDA authorization.

    Product
    RED MAMMOTH capsules, 400 mg, packaged in 10-count blisters per carton, ASIN B00KA8FBNI, barcode X001ANE0I5.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0563-2022·2022-02-23

    MAC DADDY PURPLE Capsules Recalled for Undeclared Drug Ingredients

    ABC Sales 1 Inc is recalling MAC DADDY PURPLE Capsules because they contain undeclared tadalafil and/or sildenafil, active ingredients in FDA-approved prescription drugs, making the product an unapproved drug.

    Product
    MAC DADDY PURPLE Capsules, packaged in 10-count blisters per carton, ASIN B08Z63Z4QK, UPC 742137 605764.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·22V104000·2022-02-23

    Tesla Model S Side Curtain Air Bag Inflator Defect

    Tesla is recalling 2021-2022 Model S vehicles due to side curtain air bag inflators that may have been assembled incorrectly. This could cause delayed air bag deployment during a crash, increasing injury risk.

    Product
    TESLA — TESLA MODEL S
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0630-2022·2022-02-23

    THE RED PILL EXTRA STRENGTH Capsules Recalled for Undeclared Tadalafil

    THE RED PILL EXTRA STRENGTH 800 mg capsules are being recalled because they contain undeclared tadalafil, an active ingredient in FDA-approved sexual-enhancement medications. The product was marketed and distributed as an unapproved drug nationwide via Amazon.

    Product
    THE RED PILL, EXTRA STRENGTH capsules, 800 mg, packaged in 10-count blisters packaged in a carton, ASIN B0847BSQQ5, Barcode X002G5GMJ1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0627-2022·2022-02-23

    Arrow-Trerotola Percutaneous Thrombolytic Device catheter tips may separate during use

    The FDA is recalling Arrow-Trerotola Percutaneous Thrombolytic Device catheters due to reports of tip separation during use. Approximately 3,668 units were distributed worldwide.

    Product
    Arrow-Trerotola PTD Set (Percutaneous Thrombolytic Device), PT-45509 containing components: PT-45509-S6, PT-45509-T The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0562-2022·2022-02-23

    MAC DADDY RED Capsules Recalled for Undeclared Drug Ingredients

    MAC DADDY RED Capsules are being recalled because they contain undeclared tadalafil and/or sildenafil without FDA approval. The product was distributed nationwide via Amazon Marketplace.

    Product
    MAC DADDY RED Capsules, packaged in 10-count blisters per carton, ASIN B07TLDZLY2, UPC 742137 605191.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0622-2022·2022-02-23

    Vyaire Medical Ventilators Recalled Due to Potential Ventilation Failure

    Vyaire Medical is recalling 4,189 bellavista 1000 and 1000e ventilators worldwide due to potential cessation of ventilation under specific conditions. This FDA Class I recall poses serious risk to patients who depend on these critical care devices.

    Product
    bellavista 1000 ventilator, Catalog #301.100.030 and bellavista 1000e ventilator, 301.100.130. The bellavista 1000/1000e ventilator is intended to provide positive pressure ventilatory support to adult and pediatric patients, and optionally, infant and neonatal patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0626-2022·2022-02-23

    Arrow-Trerotola Percutaneous Thrombolytic Device Kits Recalled for Tip Separation

    Teleflex is recalling Arrow-Trerotola Percutaneous Thrombolytic Device kits worldwide due to reports of tip separation during use, affecting approximately 1,874 units.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-WC containing components: PT-65709-C, PT-03009, PT-65709-HS The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0568-2022·2022-02-23

    RNAstill Specimen Collection Kits Recalled Missing FDA 510(k) Clearance

    BASE 10 GENETICS INC is recalling RNAstill Molecular Transport Medium Vials and specimen collection kits nationwide because they lack FDA 510(k) clearance. Approximately 455,791 kits were distributed across 18 states.

    Product
    RNAstill Molecular Transport Medium Vial, Catalog number MTM-001, a component of the following catalog numbers of RNAstill MTM specimen collection kits: MTM-SW03 with Oropharyngeal swab and MTMSW-05 with Nasopharyngeal swab, packaged 25 specimen collection kits per plastic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0624-2022·2022-02-23

    Teleflex Arrow-Trerotola Percutaneous Thrombolytic Device PTD Kit recalled for tip separation

    Teleflex recalls approximately 1,400 Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) kits due to reports of tip separation during use. The medical device is used for dialysis graft declotting and has been distributed worldwide.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-HFWC containing components: PT-65709-C, PT-03009, PT-65709-HFS The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0643-2022·2022-02-23

    Paragard T380A Intrauterine Contraceptive Device Recall for Non-Sterility

    CooperSurgical, Inc is recalling 48,645 cartons of Paragard T380A intrauterine contraceptive devices nationwide due to non-sterility concerns. The voluntary recall affects Lot #517001 with expiration date 1/2024.

    Product
    PARAGARD T380A (intrauterine copper contraceptive), 1 unit per carton together with an insertion tube and solid white rod in a Tyvek polyethylene pouch, Rx Only, Manufactured by Teva Women's Health Inc. a subsidiary of Teva Pharmaceuticals USA, Inc., North Wales, PA 19454, NDC…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0631-2022·2022-02-23

    365 SKINNY High Intensity Capsules Recalled for Undeclared Sibutramine

    Je Dois Lavoir LLC is recalling 365 SKINNY High Intensity Capsules (600 mg, 30-count bottles) because the product contains undeclared sibutramine, a drug previously withdrawn from the US market due to safety concerns.

    Product
    365 SKINNY High Intensity Capsules, 600 mg, 30-count bottle, BODY BALANCE INTERNACIONAL
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0628-2022·2022-02-23

    Arrow-Trerotola Thrombolytic Catheter Kits Recalled for Tip Separation During Use

    Teleflex Medical is recalling 5,530 Arrow-Trerotola PTD catheter kits due to reports of tip separation during use. The hazard could prevent the device from functioning properly to remove blood clots from dialysis access grafts.

    Product
    5 Fr. X 65 cm Arrow-Trerotola PTD Kit, Percutaneous Thrombolytic Device, REF PT-65509-HFC containing components: PT-03000, PT-65509-S (PT-65509-S2 alternative), PT-01000-D (PT-01000-D2 alternative) The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0629-2022·2022-02-23

    Arrow-Trerotola Percutaneous Thrombolytic Device Set Tip Separation Recall

    Teleflex Medical Inc. is recalling Arrow-Trerotola PTD catheter sets due to reported tip separation during use. The device is used for mechanical declotting of vascular access fistulae and grafts.

    Product
    Arrow-Trerotola PTD Set (Percutaneous Thrombolytic Device), REF PT-65509 (finished good kit) The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of native arterio-venous (AV)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0625-2022·2022-02-23

    Arrow-Trerotola Dialysis Catheter Recalled for Tip Separation During Use

    Arrow-Trerotola Over-The-Wire PTD catheters used in dialysis procedures are being recalled due to reports of tip separation during use. The FDA classified this as a Class I recall affecting 1,265 units worldwide.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-65709-W containing component: PT-65709-C The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits mechanical declotting of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0623-2022·2022-02-23

    Arrow-Trerotola Thrombolytic Device Tip Separation During Use Recalled

    Teleflex Medical is recalling Arrow-Trerotola PTD kits due to reports of tip separation during use. The affected device is used for declotting dialysis grafts and fistulae.

    Product
    Arrow-Trerotola Over-The-Wire PTD Kit, Percutaneous Thrombolytic Device, REF PT-12709-WC, containing components: PT-12709-CA, PT-12709-C, The Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) Catheter, in conjunction with the Arrow Rotator Drive Unit, permits…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0648-2022·2022-02-23

    Philips Zenition 70 Wireless Foot Switch Firmware Failure Recall

    Philips is recalling Zenition 70 wireless foot switches due to a firmware issue that can cause the device to stop responding. This could interrupt imaging procedures if alternative controls are not used.

    Product
    Zenition 70, Model #718133
    Category
    Medical Device
    Distribution
    26 states
  • HighFDA (Devices)·Z-0653-2022·2022-02-23

    Smiths Medical Medfusion Syringe Infusion Pumps Recalled for Alarm System Failures

    Smiths Medical is recalling certain Medfusion syringe infusion pumps due to intermittent alarm system failures that may occur during power-on self-tests outside the warranty period.

    Product
    Medfusion Model 3500 and 4000 Syringe Infusion Pumps and Medfusion 3010 and 3010A Syringe Infusion Pumps serviced during the same time period in which a main board was replaced using replacement main board part numbers G6000361, G6000435, G6001260, G6001560, G6001562 and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0735-2022·2022-02-23

    Frozen Chopped Spinach Recalled for Possible Listeria Contamination

    Steamable by Lidl Chopped Spinach is recalled due to possible Listeria monocytogenes contamination. Affected products were distributed to Lidl stores across eight states.

    Product
    Steamable by Lidl Chopped Spinach NET WT 12 OZ (340 g) UPC 4 056489 34380 6. Frozen product.
    Category
    Food
    Distribution
    8 states