  • SevereFDA (Devices)·Z-0099-2017·2016-11-02

    Roche URISYS 2400 Urine Analyzer Recalled for Sharp Edge Injury Risk

    Roche is recalling URISYS 2400 Urine Analyzers because a sharp edge on the sample rack tray caused four reported injuries.

    Product
    URISYS 2400 Urine Analyzer Automated Urinalysis System Product Usage: The RSD 800 is a computer-controlled stand-alone sorting system for sorting barcoded samples. The system has an online connection to the host.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0098-2017·2016-11-02

    Roche Modular Pre Analytics EVO/Plus Recall for Sharp Edge Injury Risk

    Roche is recalling Modular Pre Analytics EVO/Plus systems because a sharp edge on the sample rack tray caused four reported injuries.

    Product
    Modular Pre Analytics ( EVO/Plus) Product Usage: The RSD 800A is a computer-controlled stand-online system for decapping, aliquoting and sorting of primary tubes and for producing and sorting bar coded secondary tubes.. The system operates with an online connection to the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0100-2017·2016-11-02

    Roche COBAS INTEGRA 800 Analyzer Recalled Due to Sharp Edge Injury Reports

    Roche is recalling COBAS INTEGRA 800 analyzers after four reports of injury caused by the sharp edge of the sample rack tray.

    Product
    Roche COBAS INTEGRA 800 /800 CTS Analyzer Analyzer, Chemistry (Photometric, Discrete for Clinical use Product Usage: The system cobas p612 is a computer-controlled stand-alone system for aliquoting and sorting of barcoded sample tubes. The system operates with an online…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0245-2017·2016-11-02

    SM Fish Corp. Recalls Ossie's Roman Shmaltz Herring Due to Listeria Risk

    SM Fish Corp. is recalling 92 units of Ossie's Roman Shmaltz Herring because FDA environmental sampling found Listeria monocytogenes in the plant.

    Product
    OSSIE'S ROMAN SHMALTZ HERRING, NET WT. 7 OZ., UPC 739885109026; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereCPSC·17024·2016-11-02

    Midea Dehumidifiers Recalled Due to Fire and Burn Hazards

    GD Midea is recalling approximately 3.4 million dehumidifiers sold in the U.S. because they can overheat, smoke, and catch fire, posing serious fire and burn hazards.

    Product
    Dehumidifiers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0239-2017·2016-11-02

    SM Fish Corp. Recalls Ossie's Wasabi Herring Due to Listeria Risk

    SM Fish Corp. is recalling 65 units of Ossie's Wasabi Herring in New York and New Jersey due to potential Listeria monocytogenes contamination.

    Product
    OSSIE'S WASABI HERRING, NET WT. 7 OZ., UPC 739885109088; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Food)·F-0248-2017·2016-11-02

    SM Fish Corp. Recalls Ossie's Pickled Lox Due to Listeria Risk

    SM Fish Corp. is recalling 82 units of Ossie's Pickled Lox because FDA environmental sampling found Listeria monocytogenes in the facility.

    Product
    OSSIE'S PICKLED LOX, NET WT. 8 OZ., UPC 739885104137; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0095-2017·2016-11-02

    Roche Recalls cobas e411 Immunoassay Analyzers Due to Sharp Edge Injury Risk

    Roche is recalling 9,014 cobas e411 Immunoassay Analyzers because the sharp edge of the sample rack tray center guide rail caused four reported injuries.

    Product
    cobas e411 Immunoassay Analyzer e411: Immunoassay Analyzer Product Usage: The cobas p501/p701 instrument stores primary and secondary sample tubes. The tubes are stored in a controlled, refrigerated sample store. Automatic retrieval for add-on testing is possible at any…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0094-2017·2016-11-02

    Roche Modular Analytics Systems Recalled Due to Sharp Sample Rack Edge

    Roche is recalling Modular Analytics Combination Systems because a sharp edge on the sample rack tray caused four reported injuries. The cleaning procedure has been revised to clarify the process.

    Product
    Roche/Hitachi MODULAR Analytics Combination Systems Modular D/P: Clinical Chemistry Analyzer, Chemistry (Photometric, Discrete) for clinical use. Modular E170: Immunoassay Analyzer Product Usage: The Roche COBAS INTEGRA 800/800 CTS Analyzer is fully automated system for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0110-2017·2016-11-02

    Roche Recalls cobas 6800/8800 Systems Due to Sharp Edge Injury Risk

    Roche is recalling 9,014 cobas 6800/8800 systems because a sharp edge on the sample rack tray caused four reported injuries.

    Product
    cobas 6800/8800 system Hepatitis Viral B DNA Detection Product Usage: The cobas p512 pre-analytical system is a computer controlled fully automatic system for sorting of open and closed barcoded and centrifuged sample tubes. It includes modules for registration and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0106-2017·2016-11-02

    Roche cobas p 612 Pre-Analytical Instrument Recall for Sharp Edge Injury

    Roche is recalling cobas p 612 Pre-Analytical Instruments because the sharp edge of the sample rack tray center guide rail caused four reported injuries.

    Product
    cobas p 612 Pre-Analytical Instrument calculator/data processing module, for clinical use Product Usage: The cobas 6000 series is a fully automated, random-access, software-controlled system for immunoassay and photometric analysis intended for qualitative and quantitative…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0237-2017·2016-11-02

    SM Fish Corp. Recalls Herring for Potential Listeria Contamination

    SM Fish Corp. is recalling 106 units of Ossie's Taam Shabbos Herring due to potential Listeria monocytogenes contamination found during FDA environmental sampling.

    Product
    OSSIE'S TAAM SHABBOS HERRING, NET WT. 7 OZ., UPC 739885109057; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0104-2017·2016-11-02

    Roche RSD 800A Aliquoting System Recalled Due to Sharp Edge Injury Reports

    Roche is recalling 9,014 RSD 800A Aliquoting System calculator/data processing modules because four reports of injury were received from the sharp edge of the sample rack tray.

    Product
    RSD 800A Aliquoting System calculator/data processing module, for clinical use Product Usage: The Roche/Hitachi MODULAR Analytics System is a fully automated, random-access, software-controlled system for immunoassay and photometric analysis intended for qualitative and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·16V799000·2016-11-02

    Jeep Cherokee Recall for Driver Knee Air Bag Weld Defect

    Chrysler is recalling 2017 Jeep Cherokee vehicles because improper welds may prevent the driver's knee air bag from inflating properly.

    Product
    JEEP — JEEP CHEROKEE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0304-2017·2016-11-02

    Nova Medical Recalls Journey Rolling Walkers Due to Loose Screws

    Nova Medical is recalling 1,380 Journey Rolling Walkers because screws holding the side supports can loosen and fall out.

    Product
    4205 Journey Rolling Walker Product Usage: used to assist people in walking
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0179-2017·2016-11-02

    Porfirio's Ricotta Gnocchi Recalled for Undeclared Wheat and Milk

    Porfirio's Homeade Ricotta Gnocchi is being recalled because it may contain undeclared wheat and milk allergens.

    Product
    Porfirio's Homeade Ricotta Gnocchi Net Wt. 16 oz (1 LB.) 453 g Manufactured by Porfirio's Italian Food, Inc. 320 Anderson Street, Trenton NJ 08611 UPC 016105000319
    Category
    Food
    Distribution
    2 states
  • HighFDA (Devices)·Z-0305-2017·2016-11-02

    Hospira Symbiq Infuser Recall for Potential White Screen Error

    Hospira is recalling Symbiq One Channel Infusers because a white screen during KVO titration may allow premature programming, potentially causing therapy delays and significant injury.

    Product
    Symbiq One Channel Infuser; an Rx medical device infusion pump used to administer I.V. fluids Device is a general purpose infusion pump designed to deliver fluids, solutions, medications, agents, nutritionals, electrolytes, blood and blood products for parenteral…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0184-2017·2016-11-02

    Porfirio's Jumbo Cheese Ravioli Recalled for Undeclared Wheat and Milk

    Porfirio's 12 Jumbo Cheese Ravioli is being recalled because it may contain undeclared wheat and milk allergens.

    Product
    Porfirio's 12 Jumbo Cheese Ravioli Net Wt. 14 oz. Manufactured by Porfirio's Italian Food, Inc. 320 Anderson Street, Trenton NJ 08611
    Category
    Food
    Distribution
    2 states
  • HighFDA (Devices)·Z-0103-2017·2016-11-02

    Roche VS II Aliquoter System recalled due to sharp edge injury risk

    Roche is recalling VS II Aliquoter System calculator modules because a sharp edge on the sample rack tray caused four reported injuries.

    Product
    VS II Aliquoter System calculator/data processing module, for clinical use Product Usage: Elecysy 411 analyzer is a fully automated, random access, computer controlled analytical systems for quantitative and qualitative determinations of analytes in body fluids.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0306-2017·2016-11-02

    Hospira Symbiq Infuser Recall for Potential White Screen Error

    Hospira is recalling Symbiq Two Channel Infusers because a white screen error during KVO titration could delay therapy and cause significant injury.

    Product
    Symbiq Two Channel Infuser; an Rx medical device infusion pump used to administer I.V. fluids Device is a general purpose infusion pump designed to deliver fluids, solutions, medications, agents, nutritionals, electrolytes, blood and blood products for parenteral…
    Category
    Medical Device
    Distribution
    Distributed nationwide