The Recall Desk

State

New Hampshire product recalls

73,596 recalls have nationwide distribution and so reach New Hampshire. 4,477 additional recalls listed New Hampshire specifically in their distribution scope.

What the numbers show

Total
4,477
Critical
603
Severe
1,048
Most recent
2026-10-21

Of the 4,477 recalls naming New Hampshire we have scored against our rubric, 603 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,048 (23%) are Severe.

These figures cover only the 4,477 recalls whose distribution notice names New Hampshire specifically. The 73,596 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

1476–1500 of 78073

  • ModerateFDA (Drugs)·D-0677-2026·2026-07-22

    Nystatin Cream Recall Due to Low Potency Test Results

    Padagis US LLC is recalling Nystatin Cream USP (100,000 USP units) because long-term stability testing found assay results below specification, meaning the product may contain less active ingredient than labeled.

    Product
    NYSTATIN — NYSTATIN (NYSTATIN)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0688-2026·2026-07-22

    CAREone Earwax Removal Drops Recalled for Subpotent Active Ingredient

    CAREone Earwax Removal Drops (Carbamide Peroxide 6.5%) are recalled because the product contains significantly reduced active ingredient (~0.6% vs. expected ~6–7%) and low pH, making it ineffective.

    Product
    CAREONE EARWAX REMOVAL DROPS — CAREONE EARWAX REMOVAL DROPS (CARBAMIDE PEROXIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2743-2026·2026-07-22

    Photera 600 Phototherapy Device UV Sensor Calibration Error

    Daavlin Distributing Company is recalling 26 Photera 600 phototherapy devices nationwide because the UV sensor gain calibration is incorrect, causing inaccurate ultraviolet output readings.

    Product
    Photera 600, phototherapy device; Ultraviolet Lamp For Dermatologic Disorders
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2746-2026·2026-07-22

    Tosoh ST AIA-Pack Testosterone Diagnostic Test Kit Recall

    Tosoh Bioscience is recalling ST AIA-Pack Testosterone test kits due to low-quality control results that could produce falsely elevated or falsely low testosterone measurements, potentially leading to unnecessary testing or delayed diagnosis.

    Product
    ST AIA-Pack Testosterone, IN VITRO DIAGNOSTIC USE ONLY for the quantitative measurement of testosterone in human serum on specific Tosoh AIA System analyzers, Model Number 0025204
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0685-2026·2026-07-22

    Leader Carbamide Peroxide Earwax Removal Kit Recalled for Subpotency

    Bell Pharmaceuticals is recalling Leader Carbamide Peroxide 6.5% Earwax Removal Kit due to subpotency—the active ingredient is significantly reduced (approximately 0.6% versus the expected 6–7%) and the pH is low.

    Product
    LEADER EARWAX REMOVAL KIT EARWAX REMOVAL AID AND BULB — LEADER EARWAX REMOVAL KIT EARWAX REMOVAL AID AND BULB (CARBAMIDE PEROXIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·H-1174-2026·2026-07-22

    Amy's Organic Lentil Soup Recalled for Potential Spoilage Risk

    Amy's Kitchen is recalling Amy's Organic Soups Lentil Light in Sodium (14.5 oz cans) due to potential for spoilage. The recall affects approximately 15,350 cases distributed across multiple U.S. states and Canada.

    Product
    Amy's ORGANIC SOUPS LENTIL LIGHT IN SODIUM NET WT. 14.5 OZ. (411 g) Microwave: Place soup in a microwave-safe bowl. Cover. Cook for 1.5-2 minutes. Let sit 1 minute. Stir. Serve. Stovetop: Heat soup in a saucepan, stirring occasionally. AMY'S KITCHEN, INC. P.O. BOX 7129…
    Category
    Food
    Distribution
    28 states
  • ModerateFDA (Drugs)·D-0680-2026·2026-07-22

    Quality Choice Earwax Removal Kit Carbamide Peroxide Subpotent Drug Recall

    Bell Pharmaceuticals is recalling Quality Choice Earwax Removal Kit (Carbamide Peroxide 6.5%) due to subpotent drug content, with assay levels significantly reduced (approximately 0.6% versus expected 6–7%) and low pH levels.

    Product
    QUALITY CHOICE EARWAX REMOVAL KIT — QUALITY CHOICE EARWAX REMOVAL KIT (CARBAMIDE PEROXIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2734-2026·2026-07-22

    Papablic Replacement Brush Heads Recalled Due to Breakage Risk

    Papablic Inc is recalling Papablic Replacement Brush Heads (Model PAPA317AA) due to potential for brush heads to break. The recall affects approximately 13,400 packs distributed nationwide.

    Product
    Papablic Replacement Brush Heads. Model Number: PAPA317AA.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0684-2026·2026-07-22

    Good Neighbor Pharmacy Earwax Removal Drug Recalled for Low Potency

    Bell Pharmaceuticals is recalling Good Neighbor Pharmacy Earwax Removal (Carbamide Peroxide 6.5%) due to subpotency—the active ingredient concentration is significantly reduced from expected levels, and the product has a low pH.

    Product
    GOOD NEIGHBOR PHARMACY EARWAX REMOVAL — GOOD NEIGHBOR PHARMACY EARWAX REMOVAL (CARBAMIDE PEROXIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2744-2026·2026-07-22

    Photera 600 3-D phototherapy device UV sensor calibration error recall

    Daavlin Distributing Company is recalling Photera 600 3-D phototherapy devices because the UV sensor gain calculation is incorrect, causing inaccurate ultraviolet output measurement.

    Product
    Photera 600 3-D, phototherapy device; Ultraviolet Lamp For Dermatologic Disorders
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0687-2026·2026-07-22

    Meijer Earwax Removal Kit Recalled for Subpotent Active Ingredient

    Bell Pharmaceuticals is recalling Meijer Earwax Removal Kit (Carbamide Peroxide 6.5%) due to subpotency: the product contains significantly reduced active ingredient (~0.6% vs. expected ~6–7%) and low pH, limiting effectiveness.

    Product
    MEIJER EARWAX REMOVAL KIT — MEIJER EARWAX REMOVAL KIT (CARBAMIDE PEROXIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2736-2026·2026-07-22

    Medline Kits with Zimmer Biomet Mixing Bowls Recalled for Seal Defects

    Medline is recalling 163 kits containing Zimmer Biomet mixing bowls and spatulas due to seal nonconformities that may compromise sterility. The defect could require extended surgery time to locate an alternative device.

    Product
    Medline Kits containing Zimmer Biomet mixing bowls and spatulas TOTAL KNEE PACK DYNJT6267
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·H-1153-2026·2026-07-22

    Nutricia NOURISH Organic Meal Replacement Powder Recalled for Low Vitamin A

    Nutricia North America is recalling its NOURISH ORGANIC WHOLE FOODS MEAL REPLACEMENT PEPTIDE FORMULA BERRY MEDLEY because testing showed the product contains less vitamin A than the label states. A laboratory error led to inaccurate test results that overstated the actual vitamin A concentration in the product.

    Product
    functional formularies NOURISH ORGANIC WHOLE FOODS MEAL REPLACEMENT PEPTIDE FORMULA BERRY MEDLEY COMPLETE PLANT BASED NUTRITION NET WT. 12 OZ (341g) case UPC 8 57858 00445 8, package UPC 8 57858 00447 2
    Category
    Food
    Distribution
    49 states
  • ModerateFDA (Devices)·Z-2742-2026·2026-07-22

    Photera 400 Phototherapy Device Recalled for Incorrect UV Sensor Calibration

    Daavlin Distributing Company is recalling the Photera 400 phototherapy device because the UV sensor calibration is calculating incorrectly, resulting in lower output levels than intended.

    Product
    Photera 400, phototherapy device; Ultraviolet Lamp For Dermatologic Disorders
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2740-2026·2026-07-22

    Rio II Nasal Pillows Interface Packaging and Labeling Discrepancy Recall

    3B Medical, Inc. is recalling Rio II Nasal Pillows Interface devices due to packaging and labeling discrepancies involving product size identification and device identifiers. The affected models are RII1001 (Small), RII1002 (Medium), and RII1003 (Large).

    Product
    Brand Name: Rio" II Product Name: Rio" II Nasal Pillows Interface Model/Catalog Number: RII1001 (Small), RII1002 (Medium), RII1003 (Large) Software Version: N/A Product Description: Nasal pillows interface intended for use with positive airway pressure therapy devices. The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V470000·2026-07-21

    Ford Recalls 2025-2027 Explorer and Lincoln Aviator for Seat Recline Issue

    Ford is recalling 76,748 2025-2027 Explorer and Lincoln Aviator vehicles because an unoccupied driver's seat may recline unintentionally, potentially trapping a second-row occupant.

    Product
    FORD — FORD, LINCOLN EXPLORER, AVIATOR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • LowNHTSA·26V469000·2026-07-21

    Ember Recalls 2027 Travel Trailers Due to Incorrect VIN Labels

    Ember is recalling 2027 E-Series, Touring, and Overland travel trailers because the Federal Certification Label may list the wrong VIN, which could prevent owners from recognizing safety recalls.

    Product
    EMBER — EMBER OVERLAND SERIES, TOURING EDITION, E-SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V467000·2026-07-20

    Blue Bird Recalls 2022-2027 Vision Transit Buses for Brake Line Damage

    Blue Bird is recalling 2022-2027 Vision transit buses because an exhaust hanger pin may damage the hydraulic brake line, causing leaks and increasing fire or crash risks.

    Product
    BLUE BIRD — BLUE BIRD VISION TRANSIT BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V466000·2026-07-20

    Blue Bird Vision School Buses Recalled Due to Brake Line Fire and Crash Risk

    Blue Bird is recalling certain 2022-2027 Vision school buses because an exhaust hanger cotter pin may damage hydraulic brake lines, causing leaks that increase the risk of fire or crashes.

    Product
    BLUE BIRD — BLUE BIRD VISION SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V463000·2026-07-17

    Altec Recalls 2024-2026 AT Series Vehicles Due to Bearing Fastener Defect

    Altec is recalling 2024-2026 AT Series vehicles because turntable rotation bearing fasteners may not have been heat treated properly, posing a risk of component separation and injury.

    Product
    ALTEC — ALTEC AT SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V464000·2026-07-17

    Foretravel Recalls 2027 Realm Motorcoaches Due to Fire Risk

    Foretravel is recalling 2027 Realm Presidential Motorcoaches because a fan assembly circuit board may overheat, increasing the risk of a fire.

    Product
    FORETRAVEL — FORETRAVEL REALM
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V462000·2026-07-17

    Turtle Top Recalls 2026 Terra Ford Transit Buses Due to Lift Control Failure

    Turtle Top is recalling 2026 Terra Ford Transit buses because an electrical contactor may fail, preventing the wheelchair lift from stopping. This defect increases the risk of injury.

    Product
    TURTLE TOP — TURTLE TOP TERRA FORD TRANSIT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26C004000·2026-07-17

    Evenflo Recalls Reo by Revolve360 Child Seats for Headrest Shift Risk

    Evenflo is recalling specific Reo by Revolve360 child seats because the headrest may shift during a crash, increasing injury risk.

    Product
    CHILD SEAT:SHELL:HEADREST:LOCKING MECHANISM recall
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·26V465000·2026-07-17

    Great Dane Recalls 2027 Champion Trailers for Rear Impact Guard Defect

    Great Dane is recalling 2027 Champion dry van trailers because they may lack required rear impact guard extension channels, increasing injury risk in crashes.

    Product
    GREAT DANE — GREAT DANE CHAMPION
    Category
    Vehicle
    Distribution
    Distributed nationwide