  • HighFDA (Devices)·Z-1596-2026·2026-04-01

    I.T.S. pilon and tibia plates heat more in MRI than stated

    I.T.S. GmbH is recalling Pilon Plates with Angular Stability and Anterolateral Tibia Plates because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    Pilonplate with Angular Stability, with the below descriptions and corresponding article numbers. 1. Anterolateral Tibia Plate; Article Numbers: 21311-11, 21311-15, 21311-7, 21312-11, 21312-15, 21312-7. 2. Pilon Plate 4mm; Article Numbers: 21094-10, 21094-4, 21094-6…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1638-2026·2026-04-01

    Olympus Everest bipolar forceps model 3005 jaws may break

    Olympus is recalling Everest Bipolar Cutting Forceps model 3005 because a supplier did not adequately validate the welding process, and defective welds can cause the jaw to break during clinical use.

    Product
    Brand Name: Olympus Everest Bipolar Cutting Forceps, 5 mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3005 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achieved…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1601-2026·2026-04-01

    I.T.S. fibula and tubular plates heat more in MRI than stated

    I.T.S. GmbH is recalling the Fibula Plate PROlock with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    I.T.S. Fibula Plate PROlock with Angular Stability with the below descriptions and corresponding article numbers. 1. Distal Tubular Plate; Article Numbers: 21602-3, 21602-4, 21602-5, 21602-6, 21602-7, 21602-8, 21603-3, 21603-4, 21603-5, 21603-6, 21603-7, 21603-8. 2.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1611-2026·2026-04-01

    Olympus endoscope air water valves no longer compatible with named reprocessors

    Olympus is recalling the MAJ-1444 Endoscope Air/Water Valve because the MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.

    Product
    Olympus Endoscope Air/Water Valve - MAJ-1444. Model Number: MAJ-1444.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1641-2026·2026-04-01

    Olympus HALO PKS cutting forceps jaws may break from defective welds

    Olympus is recalling HALO PKS Cutting Forceps because a supplier did not adequately validate the welding process, and defective welds can cause the forceps jaw to break during clinical use.

    Product
    Brand Name: Olympus HALO PKS Cutting Forceps, 5mm 33cm Product Name: HALO PKS Cutting Forceps Model/Catalog Number: HACF0533 Product Description: The HALO PKS Cutting Forceps are intended to be passed through a 5 mm laparoscopic cannula. Coagulation is achieved using…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1602-2026·2026-04-01

    I.T.S. distal humeral plates heat more in MRI than stated

    I.T.S. GmbH is recalling Distal Humeral Plates with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    Distal Humeral Plates with Angular Stability with the below descriptions and corresponding article numbers. 1. Cortical Screw, Locking; Article Numbers: 37351-10-N, 37351-12-N, 37351-14-N, 37351-16-N, 37351-18-N, 37351-20-N, 37351-22-N, 37351-24-N, 37351-26-N, 37351-28-N…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1645-2026·2026-04-01

    BD Alaris system labeling omits required TLS version for secure Wi-Fi

    CareFusion is recalling the BD Alaris System with Guardrails Suite MX because the product labeling does not indicate which TLS version must be enabled on the hospital network for secure Wi-Fi communication.

    Product
    BD Alaris" System with Guardrails" Suite MX with Point of Care Unit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1631-2026·2026-04-01

    BiDop 3 pocket Doppler labeling includes uncleared fetal indication

    Koven Technology is recalling the BiDop 3 Pocket Doppler packaged with a fetal probe because the product labeling includes a fetal indication for use that is not cleared under its 510(k).

    Product
    Brand Name: BiDop 3 Product Name: BiDop 3 Pocket Doppler (ES-100V3) with BT2M20S8C fetal probe Model/Catalog Number: ES-100V3 (device); BT2M20S8C (2 MHz fetal probe). Software Version: N/A Product Description: Hand-held, battery-powered ultrasonic Doppler blood-flow detector…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0401-2026·2026-04-01

    Sodium iodide capsule packs recalled after failing capsule specifications

    Radnostix is recalling three lots of the Gelatin Capsule Pack used with the Sodium Iodide I-131 Kit because the product failed tablet and capsule specifications.

    Product
    SODIUM IODIDE I-131 — SODIUM IODIDE I-131 (SODIUM IODIDE I-131)
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1623-2026·2026-04-01

    Philips OMNI II TEE transducer labelling updated to define useful life

    Philips is recalling two OMNI II TEE Ultrasound Transducers to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips OMNI II TEE Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1627-2026·2026-04-01

    Philips X3-1 ultrasound transducer labelling updated to define useful life

    Philips is recalling the X3-1 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips X3-1 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1624-2026·2026-04-01

    Philips OMNI III TEE transducer labelling updated to define useful life

    Philips is recalling the OMNI III TEE Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips OMNI III TEE Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1620-2026·2026-04-01

    Philips L12-5 ultrasound transducer labelling updated to define useful life

    Philips is recalling the L12-5 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips L12-5 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1626-2026·2026-04-01

    Philips S5-2 ultrasound transducer labelling updated to define useful life

    Philips is recalling one S5-2 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips S5-2 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1621-2026·2026-04-01

    Philips L17-5 ultrasound transducer labelling updated to define useful life

    Philips is recalling two L17-5 Ultrasound Transducers to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips L17-5 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1628-2026·2026-04-01

    Philips X7-2 ultrasound transducer labelling updated to define useful life

    Philips is recalling the X7-2 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips X7-2 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1625-2026·2026-04-01

    Philips S4-1 ultrasound transducer labelling updated to define useful life

    Philips is recalling the S4-1 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips S4-1 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1618-2026·2026-04-01

    Philips 3D6-2 ultrasound transducer labelling updated to define useful life

    Philips is recalling the 3D6-2 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips 3D6-2 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1619-2026·2026-04-01

    Philips C9-4 ultrasound transducer labelling updated to define useful life

    Philips is recalling one C9-4 Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips C9-4 Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1622-2026·2026-04-01

    Philips Mini Multi TEE transducer labelling updated to define useful life

    Philips is recalling the Mini Multi TEE Ultrasound Transducer to provide clarification and labelling that defines the useful life of ultrasound transducers in the field.

    Product
    Philips Mini Multi TEE Ultrasound Transducer
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V201000·2026-03-31

    2025–2026 Ford Bronco Sport and Maverick Occupant Sensor Recall

    Ford is recalling certain 2025–2026 Bronco Sport and Maverick vehicles because the front passenger occupant classification sensor may fail to detect a passenger, risking failure of the airbag to deploy in a crash.

    Product
    FORD — FORD MAVERICK, BRONCO SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V205000·2026-03-31

    2026 Ford Explorer and Mustang Engine Piston Circlip Defect Recall

    Ford is recalling certain 2026 Explorer and Mustang vehicles because engine piston circlips may have been incorrectly installed, risking loss of drive power and increasing crash risk.

    Product
    FORD — FORD EXPLORER, MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide