8601–8625 of 73014

  • SevereNHTSA·24V885000·2024-11-22

    Brinkley Model Z fifth wheel pin box fasteners may be undertightened

    Brinkley RV is recalling certain 2024-2025 Model Z fifth wheel trailers with Curt Helux pin boxes because the pin box fasteners may have been improperly tightened.

    Product
    BRINKLEY RV — BRINKLEY RV MODEL Z
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·25053·2024-11-21

    Dorel Wall Beds Recalled for Serious Detachment and Crush Hazards

    About 69,300 Dorel wall beds sold online may detach from the wall and fall. The manufacturer has received 22 reports of beds falling, resulting in 10 injuries including concussions and contusions.

    Product
    Dorel Wall Beds
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·030-2024-EXP·2024-11-21

    Yu Shang Food Recalls Ready-to-Eat Meat and Poultry Due to Listeria

    Yu Shang Food, Inc. is recalling approximately 72,240 pounds of ready-to-eat meat and poultry products due to possible Listeria monocytogenes contamination.

    Product
    Yushang Food Inc. — Yu Shang Food, Inc. Recalls Ready-To-Eat Meat and Poultry Products Due to Possible Listeria Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereCPSC·25052·2024-11-21

    Segway Ninebot P100 KickScooters Recalled for Broken Front Fork and Fall Hazards

    Segway is recalling about 1,400 Ninebot P100 KickScooters because the front fork can break, causing falls and injuries. The company has received 31 reports of fork breakage, including 6 reports of injuries such as fractures, cuts, scrapes, bruises, and shoulder pain.

    Product
    Segway Ninebot P100 KickScooters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V878000·2024-11-21

    Toyota Corolla steering intermediate shafts may fracture and detach

    Toyota is recalling certain 2023-2024 Corolla and Corolla Hybrid vehicles because manufacturing cracks may cause the steering intermediate shaft to fracture and detach.

    Product
    TOYOTA — TOYOTA COROLLA, COROLLA HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V880000·2024-11-21

    International Recalls 2022-2025 HX Trucks for Brake Release Delay

    International is recalling 2022-2025 HX trucks because the service brake may take longer than expected to release, increasing crash risk.

    Product
    INTERNATIONAL — INTERNATIONAL HX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25051·2024-11-21

    Nerf Barrage Youth Bicycle Helmets Recalled for Head Injury Risk

    About 6,500 Nerf Barrage youth helmets sold at Walmart (2022–2024) are recalled for retention system failures violating federal safety standards. No injuries reported. Consumers should stop using the helmets and contact Todson for a refund.

    Product
    Nerf Barrage Youth Bike Helmets
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·24V882000·2024-11-21

    Honda Africa Twin fuel injection software may stall the engine

    Honda is recalling certain 2022 and 2024-2025 CRF1100 Africa Twin motorcycles because an FI-ECU software error may cause an engine stall or loss of power with Wheelie Control active.

    Product
    HONDA — HONDA CRF1100
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·24V879000·2024-11-21

    Hyundai Elantra and Santa Fe rearview cameras have damaged circuit boards

    Hyundai is recalling certain 2021-2022 Santa Fe and Elantra vehicles because a damaged printed circuit board may cause the rearview camera image to fail. 226,118 units affected.

    Product
    HYUNDAI — HYUNDAI SANTA FE HYBRID, ELANTRA N, SANTA FE PLUG-IN HYBRID, SANTA FE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·25054·2024-11-21

    South Shore cribs recalled for entrapment hazard in slat spacing

    South Shore cribs sold from July 2020 to February 2024 have wider-than-standard slat spacing, creating an entrapment hazard for children. The company is offering full refunds and consumers should stop using the recalled cribs immediately.

    Product
    South Shore Cribs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0304-2025·2024-11-20

    Draeger Atlan A350 Anesthesia Workstation Piston Ventilator Failure

    Draeger Medical is recalling the Atlan A350 anesthesia workstation due to failures of the piston ventilator that either occurred before use or during patient anesthesia. Approximately 1,492 units are affected.

    Product
    Brand Name: Atlan Product Name: Atlan A350 Model/Catalog Number: 8211500 Software Version: Not applicable Component: Not applicable
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0310-2025·2024-11-20

    Monoject Insulin Syringes Recalled for Incompatibility with Needleless IV Connectors

    Cardinal Health recalled approximately 371,326 Monoject U-100 insulin syringes due to incompatibility with needleless IV connectors. Affected units should not be used for IV push insulin administration via these connectors.

    Product
    Monoject U-100 1 mL Insulin Syringe Luer-Lock with Tip Cap Soft Pack, REF 1188100777
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalUSDA FSIS·031-2024·2024-11-20

    Wolverine Packing Recalls Ground Beef Due to E. Coli O157:H7 Contamination

    Wolverine Packing Co. is recalling approximately 167,277 pounds of ground beef products due to possible E. coli O157:H7 contamination linked to an illness cluster in Minnesota.

    Product
    Wolverine Packing Co. — Wolverine Packing Co. Recalls Ground Beef Products Due to Possible E. Coli O157:H7 Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E099000·2024-11-20

    Agility Fuel Solutions Recalls CNG Fuel Systems Due to Valve Cracks

    Agility Fuel Solutions is recalling certain CNG fuel systems because manual cylinder valves may develop stress corrosion cracks, causing a natural gas leak that increases fire risk.

    Product
    FUEL SYSTEM, OTHER recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0404-2025·2024-11-20

    AVID Medical Recalls Halyard Laparoscopy Trays Due to Metal Flakes

    AVID Medical is recalling 42 Halyard Laparoscopy Trays because sponge forceps and towel clamps may release metal flakes that could enter a patient's surgical site.

    Product
    Halyard LAPAROSCOPY TRAY - Medical convenience kits Model Number: LANC006-25
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0357-2025·2024-11-20

    Medline Recalls Non-Sterile Urinalysis Kit Specimen Containers

    Medline Industries is recalling 626,305 urinalysis kits because the specimen containers are labeled sterile but are non-sterile, posing a risk of unnecessary treatment or hospitalization.

    Product
    URINALYSIS KIT 4, SKU DYLAB1021; Component No. 503581
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24E098000·2024-11-20

    Lippert Recalls Fifth Wheel Pin Boxes Due to Fastener Issues

    Lippert is recalling specific Curt Helux Pin Boxes installed in Lippert 5W Chassis because fasteners may be improperly tightened, increasing crash risk.

    Product
    TRAILER HITCHES:FIFTH WHEEL ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0406-2025·2024-11-20

    AVID Medical Recalls Halyard C Section Bundles Due to Metal Flakes

    AVID Medical, Inc. is recalling Halyard C Section Bundles because small metal flakes may detach from sponge forceps and towel clamps, posing a risk of foreign body reactions.

    Product
    Halyard C SECTION BUNDLE - Medical convenience kits Model Number: LANC015-34
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0296-2025·2024-11-20

    Philips LifeVent EVO2 ventilators recalled for potential sensor accuracy failure

    Philips Respironics is recalling LifeVent EVO2 ventilators due to potential aerosol deposit accumulation on the internal flow sensor that could cause inaccurate measurements during ventilation.

    Product
    LifeVent EVO2. Model Number: SP2100X26B. Intended for invasive and non-invasive ventilation of pediatric through adult patients weighing at least 2.5 kg in institutional, home, and non-emergency transport settings.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereNHTSA·24V877000·2024-11-20

    Hyundai Tucson console wiring may allow shifting out of Park unbraked

    Hyundai is recalling certain 2025 Tucson and Santa Cruz vehicles because misrouted console wiring may allow the transmission to shift out of Park without the brake applied.

    Product
    HYUNDAI — HYUNDAI SANTA CRUZ, TUCSON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0291-2025·2024-11-20

    Philips Trilogy Evo ventilators recall: flow sensor fouling risk

    Philips Respironics is recalling Trilogy Evo ventilators due to potential aerosol deposits on the internal flow sensor, which could cause inaccurate flow measurements during ventilation.

    Product
    Trilogy Evo. Model Numbers: DS2110X11B, UDS2110X11B, RDS2110X11B, CA2110X12B, JP2110X16B, IN2110X15B, DE2110X13B, AU2110X15B, BL2110X15B, EU2110X15B, BR2110X18B, LA2110X15B, EE2110X15B, FR2110X14B, GB2110X15B, ND2110X15B, ES2110X15B, IA2110X15B, IT2110X21B, KR2110X15B, TR2110X15B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0290-2025·2024-11-20

    Trilogy Evo O2 Ventilators Recalled for Potential Flow Sensor Malfunction

    Philips Respironics recalled 24,249 Trilogy Evo O2 ventilators because in-line nebulizer configurations may allow aerosol deposits to accumulate on the device's flow sensor, potentially causing inaccurate flow measurements.

    Product
    Trilogy Evo O2. Model Numbers: FP2100X10, DS2100X11B, IN2100X15B, DE2100X13B, IA2100X15B, EU2100X15B, LA2100X15B, EE2100X15B, FX2100X15B, ES2100X15B, ND2100X15B, FR2100X14B, IT2100X21B, JP2100X16B, IN2100X19, EU2100X19. Intended for invasive and non-invasive ventilation of pedi
    Category
    Medical Device
    Distribution
    Distributed nationwide