The Recall Desk

State

Minnesota product recalls

73,218 recalls have nationwide distribution and so reach Minnesota. 7,841 additional recalls listed Minnesota specifically in their distribution scope.

What the numbers show

Total
7,841
Critical
1,139
Severe
1,906
Most recent
2026-10-02

Of the 7,841 recalls naming Minnesota we have scored against our rubric, 1,139 (15%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,906 (24%) are Severe.

These figures cover only the 7,841 recalls whose distribution notice names Minnesota specifically. The 73,218 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

14501–14525 of 81059

  • HighFDA (Devices)·Z-0378-2024·2023-11-29

    Biomet Compress Device Anchor Plugs recalled for metal burrs in transverse holes

    Biomet is recalling Compress Device Short Anchor Plugs due to potential metal burrs in the transverse holes that may prevent proper placement of drill pins during surgery, potentially extending surgical time.

    Product
    Compress Device Short Anchor Plug, 10 MM-Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178552
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0327-2024·2023-11-29

    Bronchoscopes Recalled Due to Inadequate Air Drying Process

    Aizu Olympus recalls bronchoscopes due to unvalidated air drying process. Some returned units after repair contain water in channels, creating infection risk.

    Product
    Bronchoscope-for endoscopy and endoscopic surgery within the airways and tracheobronchial tree. Model Numbers: BF-1T150, BF-1T60, BF-1TH190, BF-1TQ170, BF-3C160, BF-3C40, BF-H190, BF-MP190F, BF-MP60, BF-P150, BF-P190, BF-P60, BF-Q170, BF-Q190, BF-XP190, BF-XP60, BF-XT160…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2024·2023-11-29

    Biomet Compress Anchor Plugs Recalled for Metal Burrs in Transverse Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs (18 MM) due to metal burrs in transverse holes that may prevent proper drill or pin placement, potentially extending surgery time.

    Product
    Compress Device Segmental Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178408
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0389-2024·2023-11-29

    Philips Achieva 1.5T MRI systems recalled for potential gradient coil fire risk

    Philips is recalling Achieva 1.5T MRI systems due to potential gradient coil failure that could produce smoke and/or fire. Approximately 520 units have been distributed nationwide and internationally.

    Product
    Achieva 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0387-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled for metal burrs

    Biomet is recalling the Compress Device Short Anchor Plug due to metal burrs in transverse holes that may prevent proper insertion of drill or pins, potentially extending surgical time. No injuries have been reported.

    Product
    Compress Device Short Anchor Plug, 26 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178568
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0353-2024·2023-11-29

    BioFire FilmArray TORCH power switch may fail from electrical arcing

    BioFire FilmArray TORCH diagnostic devices have a power switch that may degrade from internal arcing and carbon buildup, potentially causing electrical short, device overheating, or failure to power on.

    Product
    FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scanner, touch screen computer and USB ports. The BioFire FilmArray Torch (BioFire Torch) is an automated in vitro diagnostic (IVD) device intended for use with FDA-cleared or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0346-2024·2023-11-29

    Olympus endoscopes recalled for potential water contamination in channels

    Aizu Olympus Co., Ltd. is recalling duodenovideoscope models due to an unvalidated channel air drying process. Water remaining in the channels after repair poses a potential contamination risk that could lead to infection.

    Product
    Duodenovideoscope-EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery Model Numbers: TJF-145, TJF-150, TJF-Q180V, TJF-Q190V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0359-2024·2023-11-29

    Blood Gas Analyzer Cartridges Recalled for Falsely Elevated Oxygen Readings

    Instrumentation Laboratory recalls GEM Premier 3000 PAK blood gas analyzer cartridges due to measurement errors in low oxygen detection. The devices may falsely indicate normal oxygen levels when levels are dangerously low, potentially delaying treatment.

    Product
    GEM Premier 3000 PAK - pH, pCO2, pO2, Hct, Na+, K+, Ca++, Glucose and Lactate, Part Numbers 00024315009, 00024330009, 00024345009, 00024360009
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0341-2024·2023-11-29

    Colonoscopes recalled over unvalidated channel drying process

    Aizu Olympus colonoscopes are being recalled because the air drying process for the instrument channel was not properly validated. Some units returned after repair had moisture in the channel, creating a risk of contamination and infection.

    Product
    Colonoscope-indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve). Model Numbers: PCF-H180AI, PCF-H180AL, PCF-H190DI, PCF-H190DL, PCF-H190I, PCF-H190L, PCF-H190TI, PCF-H190TL, PCF-HQ190I, PCF-HQ190L…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0383-2024·2023-11-29

    Biomet Compress Device Anchor Plug Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (20 MM) because metal burrs in transverse holes prevent surgical instruments from passing through, potentially extending surgery time.

    Product
    Compress Device Short Anchor Plug, 20 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0342-2024·2023-11-29

    Sigmoidovideoscope models recalled due to improper channel drying process

    Aizu Olympus sigmoidovideoscope (model PCF-S) units are being recalled due to an unvalidated channel drying process. Some repaired units returned with water in channels, risking contamination and infection.

    Product
    Signmoidovideoscope-For endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum and sigmoid colon). Model Number: PCF-S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0385-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug Recalled Due to Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (23 MM) due to potential metal burrs in transverse holes that may prevent proper insertion of surgical instruments, potentially extending surgery time. Distribution includes US and multiple international countries.

    Product
    Compress Device Short Anchor Plug, 23 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178565
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0376-2024·2023-11-29

    Compress Device Anchor Plugs Recalled for Metal Burrs in Surgical Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through properly. The defect may result in extended surgery time.

    Product
    Compress Device Segmental Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0371-2024·2023-11-29

    Compress Device Anchor Plugs recalled due to metal burrs

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs in transverse holes that may prevent drill or pins from passing through, potentially extending surgical time.

    Product
    Compress Device Segmental Anchor Plug, 12 MM -For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178402
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0363-2024·2023-11-29

    Horizon manual resuscitators recalled for CO2 rebreathing hazard

    SunMed Holdings is recalling Ventlab Horizon manual resuscitators due to a backwards leak in the integrated manometer that allows carbon dioxide rebreathing. The affected devices were manufactured from September 2018 to the present and distributed nationwide.

    Product
    Ventlab, LLC Horizon manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. Horizon Adult Resuscitator REF #s: 9122HZ, HZI9000, HZI9108, 9106HZ, 9110HZ, 9120HZ, 9111HZ, 9100HZ, 9105HZ, 9108HZ, 9006HZ, 9002HZ; 2. Horizon Infant…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0394-2024·2023-11-29

    Intera 1.5T MRI System Recall: Gradient Coil Fire Risk

    Philips is recalling the Intera 1.5T Power/Pulsar MRI system due to potential failure in the gradient coil component that could produce smoke and/or fire.

    Product
    Intera 1.5T Power/Pulsar
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0321-2024·2023-11-29

    Medtronic Mo.Ma Ultra Cerebral Protection Device Labeling Error

    Medtronic is recalling 173 units of the Mo.Ma Ultra Proximal Cerebral Protection Device due to incorrect labeling that prevents proper identification of inflation and deflation ports on the device manifold.

    Product
    Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device, Model Number MOM0130069X6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0373-2024·2023-11-29

    Biomet Compress Device Segmental Anchor Plugs Recalled for Metal Burrs

    Biomet has recalled certain Compress Device Segmental Anchor Plugs (16 MM) due to metal burrs in the transverse holes. These burrs may prevent the drill or pins from passing through, potentially extending surgical time.

    Product
    Compress Device Segmental Anchor Plug, 16 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178406
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0393-2024·2023-11-29

    Philips MRI systems recalled for potential gradient coil fire hazard

    Philips is recalling 102 Intera 1.5T MRI systems worldwide due to a potential gradient coil failure that could produce smoke and fire. The affected devices are identified by product numbers 781195 and 781295.

    Product
    Intera 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0358-2024·2023-11-29

    Blood Gas Analyzer Cartridges Recalled for Potential Oxygen Measurement Errors

    The FDA is recalling GEM Premier 3000 PAK cartridges manufactured by Instrumentation Laboratory because they may incorrectly report high oxygen levels in patients with low blood oxygen, potentially delaying critical treatment.

    Product
    GEM Premier 3000 PAK - pH, pCO2, pO2, Hct, Na+, K+, Ca++, Part Numbers 00024307507, 00024315007, 00024330007, 00024345007, 00024360007
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0361-2024·2023-11-29

    Ventlab AirFlow Manual Resuscitators Recalled for CO2 Rebreathing Risk

    SunMed Holdings is recalling Ventlab AirFlow manual resuscitators nationwide due to a backwards leak in the integrated manometer that allows CO2 rebreathing. Users should immediately discontinue use and contact the manufacturer.

    Product
    Ventlab, LLC AirFlow manual resuscitator devices with integrated manometer, multiple accessory configurations to include: 1. AirFlow Adult Resuscitator REF #s: AF1140MB-M5, AF1140MB-D5, AF5142OB, AF5142MB, AF5142MB-D235, AF1142MBP, AF5142MBP, AF5140MB, AF5140MB-2…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0390-2024·2023-11-29

    Philips Achieva 1.5T MRI Device Recalled for Gradient Coil Fire Risk

    Philips is recalling 68 Achieva 1.5T MRI machines due to potential gradient coil component failure that could produce smoke and fire. No injuries have been reported.

    Product
    Achieva 1.5T Conversion
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0349-2024·2023-11-29

    BD Alaris Pump Infusion Sets Contain Undisclosed DEHP

    BD Alaris Pump infusion sets labeled as DEHP-free actually contain di(2-ethylhexyl) phthalate. The worldwide recall affects multiple catalog numbers distributed throughout the US and internationally.

    Product
    BD Alaris Pump infusion sets (Product Name, Catalog #) BD AlarisTM Pump Infusion Set Vented syringe adapter Smallbore Tubing, Catalog # 10010483; BD AlarisTM Pump Infusion Set 1.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-site, Catalog # 10010453; BD…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0330-2024·2023-11-29

    Choleodochoscope Models Recalled Due to Unvalidated Air Drying Process

    Aizu Olympus choleodochoscopes with unvalidated air drying processes may retain water in the channel after repair, risking microbial contamination and patient infection. Affected models: CHF-BP30, CHF-CB30L, CHF-P60.

    Product
    Choleodochoscope. Model Numbers: CHF-BP30, CHF-CB30L, CHF-P60.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0365-2024·2023-11-29

    SafeSpot Manual Resuscitators Recalled for CO2 Rebreathing Risk

    SunMed Holdings is recalling SafeSpot manual resuscitators with integrated manometers due to a backwards leak that allows CO2 rebreathing. The defect affects multiple accessory configurations distributed nationwide.

    Product
    Ventlab, LLC SafeSpot manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. SafeSpot Infant Resuscitator REF #s: SS3200OBPC-T, SS3204MB-D12, SS3200MB-2, SS3200MB-D1, SS3200OBP, SS3200MB-MMC, SS3200MBP-M00, SS3200MB-PW, SS3200MBP-2I…
    Category
    Medical Device
    Distribution
    Distributed nationwide