  • HighFDA (Devices)·Z-1642-2026·2026-04-01

    Olympus PKS cutting forceps 3005PK jaws may break from defective welds

    Olympus is recalling PKS Cutting Forceps model 3005PK because a supplier did not adequately validate the welding process and defective welds can cause the jaw to break during clinical use.

    Product
    Brand Name: Olympus PKS Cutting Forceps, 5mm 33cm Product Name: PKS Cutting Forceps Model/Catalog Number: 3005PK Product Description: The PKS Cutting Forceps are intended to be passed through a 5mm cannula. Coagulation is achieved using electrosurgical energy under visualiza
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1608-2026·2026-04-01

    I.T.S. pelvic reconstruction plates heat more in MRI than stated

    I.T.S. GmbH is recalling the Pelvic Reconstruction System PRS RX and PRS Phoenix because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    Brand Name: I.T.S. Pelvic Reconstruction System (PRS RX & PRS Phoenix) with the below descriptions and corresponding article numbers. 1. Anterior Column Plate; Article Numbers: 21218-16, 21219-16. 2. Anterior Column Plate; Article Numbers: 21218-14, 21219-14. 3. Biplanar 2-C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0596-2026·2026-04-01

    Ajinomoto Ling Ling Fried Rice Recalled for Glass Contamination

    Ajinomoto Foods North America is recalling Item 81097 Ling Ling Restaurant Style Fried Rice due to glass fragments measuring 1-3 cm long and 2-4 mm wide found in the product. Affected units with Best By dates 9/21/2026 through 3/8/2027 were distributed across 40 U.S. states.

    Product
    Item 81097 Ajinomoto Ling Ling Restaurant Style Fried Rice Savory Vegetable - A Chinese Style Fried Rice with Edamame, Carrots, Fire Roasted Corn & Red Bell Peppers Prepared with Sweet Soy Sauce Infused Rice. Net wt. 17oz. Retail box UPC 010878810915. Product packaging is flexib
    Category
    Food
    Distribution
    43 states
  • HighFDA (Food)·H-0589-2026·2026-04-01

    Chilli Spanish Peanuts First Street recalled for glass contamination

    Western Mixers Produce & Nuts, Inc. is recalling First Street Chilli Spanish Peanuts (11 oz) because glass fragments were found in sealed containers. Affected lots have expiration dates of 2/11/2027, 2/13/2027, and 2/23/2027.

    Product
    Chilli Spanish Peanuts, First Street brand, 11oz clear plastic container. UPC: None Item Code: 2608-T20
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·26V209000·2026-04-01

    Audi Q3 recalled over remote sunroof closing from out of sight

    Volkswagen Group of America is recalling 6,077 Audi Q3 vehicles because incorrect software may allow remote sunroof closing from a distance where the operator cannot clearly see the sunroof.

    Product
    AUDI — AUDI Q3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0406-2026·2026-04-01

    Teva octreotide acetate injection recalled over sterility assurance deficiencies

    Teva is recalling twelve lots of Octreotide Acetate for Injectable Suspension after quality system deficiencies were identified during an FDA inspection at the contract manufacturer.

    Product
    OCTREOTIDE ACETATE — OCTREOTIDE ACETATE (OCTREOTIDE ACETATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1604-2026·2026-04-01

    I.T.S. distal ulna plates heat more in MRI than instructions state

    I.T.S. GmbH is recalling the Distal Ulna Locking and Ulna Osteotomy Locking Systems because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    I.T.S. DUL (Distal Ulna Locking) System and UOL (Ulna Osteotomy Locking) System with the below descriptions and corresponding article numbers. 1. I.T.S. DUL (Distal Ulna Locking) System, Distal Ulna Plate; Article Numbers: 21232-3, 21232-4, 21232-6, 21233-3, 21233-4, 21233-6, 21
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1597-2026·2026-04-01

    I.T.S. olecranon plates heat more in MRI than instructions state

    I.T.S. GmbH is recalling Olecranon Plates with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    Olecranonplate with Angular Stability with the below descriptions and corresponding article numbers. 1. Olecranon Hook Plate; Article Numbers: 21112-7, 21114-5, 21113-9. 2. Olecranon Plate; Article Numbers: 21111-6, 21111-8, 21111-12.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1607-2026·2026-04-01

    I.T.S. hand locking plates heat more in MRI than instructions state

    I.T.S. GmbH is recalling the HLS Hand Locking Plates System because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    HLS - Hand Locking Plates System with the below descriptions and corresponding article numbers. 1. Cortical Screw; Article Numbers: 32151-6, 32151-8, 32151-9, 32151-10, 32151-11, 32151-12, 32151-13, 32151-14, 32151-15, 32151-16, 32151-18, 32151-20. 2. HLS Plate, 2 T-Shape
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0600-2026·2026-04-01

    Ajinomoto Vegetable Gyoza Dumplings recalled for glass fragments

    Ajinomoto Foods North America Inc. is recalling Vegetable Gyoza Dumplings (UPC 071757055483) due to the presence of glass fragments in the product, which could pose a choking or injury hazard if ingested.

    Product
    Item 6430143 Ajinomoto Vegetable Gyoza Dumplings 12ct. Net wt. 8.92oz. per package. Retail package UPC: 071757055483. Product packaging is flexible bags in a master case or flexible bags in cartons in a master case. There are 20/8.92oz. packages or 11.15 lbs. per case. Carton UP
    Category
    Food
    Distribution
    43 states
  • HighFDA (Devices)·Z-1638-2026·2026-04-01

    Olympus Everest bipolar forceps model 3005 jaws may break

    Olympus is recalling Everest Bipolar Cutting Forceps model 3005 because a supplier did not adequately validate the welding process, and defective welds can cause the jaw to break during clinical use.

    Product
    Brand Name: Olympus Everest Bipolar Cutting Forceps, 5 mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3005 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achieved u
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0595-2026·2026-04-01

    Ajinomoto Golden Tiger Vegetable Fried Rice recalled for glass fragments

    Ajinomoto Foods North America Inc. is recalling Ajinomoto Golden Tiger Vegetable Fried Rice due to the presence of glass fragments varying from 1–3 cm long and 2–4 mm wide in the product.

    Product
    Item 5654390 Ajinomoto Golden Tiger Vegetable Fried Rice - Long grain white rice and crispy vegetables in a savory sauce. Net wt. 3lbs per bag. Retail bag UPC 076366565439. Product packaging is flexible bags in a master case or flexible bags in cartons in a master case. There ar
    Category
    Food
    Distribution
    43 states
  • HighFDA (Devices)·Z-1601-2026·2026-04-01

    I.T.S. fibula and tubular plates heat more in MRI than stated

    I.T.S. GmbH is recalling the Fibula Plate PROlock with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    I.T.S. Fibula Plate PROlock with Angular Stability with the below descriptions and corresponding article numbers. 1. Distal Tubular Plate; Article Numbers: 21602-3, 21602-4, 21602-5, 21602-6, 21602-7, 21602-8, 21603-3, 21603-4, 21603-5, 21603-6, 21603-7, 21603-8. 2. Fibul
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1605-2026·2026-04-01

    I.T.S. foot locking plates heat more in MRI than stated

    I.T.S. GmbH is recalling the FLS Foot Locking Plates System and HOL Hallux Osteotomy Locking Plate because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    FLS - Foot Locking Plates System and HOL - Hallux Osteotomy Locking Plate with the below descriptions and corresponding article numbers. 1. FLS - Foot Locking Plates System, Cancellous Stabilization Screw; Article Numbers: 37303-10, 37303-12, 37303-14, 37303-16, 37303-18, 373
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0615-2026·2026-04-01

    Savannah Bee Company Honey BBQ Sauce Mustard Undeclared Allergens

    Savannah Bee Company is recalling Honey BBQ Sauce Mustard bottles containing an undeclared different flavor product with soy and wheat allergens not listed on the label.

    Product
    SAVANNAH BEE COMPANY HONEY BBQ SAUCE MUSTARD NET 16 FL OZ (453g), PACKED IN BOTTLES. INGREDIENTS: MUSTARD (DISTILLED VINEGAR, WATER, MUSTARD SEED, SALT, SPICES (INCLUDING PAPRIKA AND TUMERIC), NATURAL FLAVOR, GARLIC), HONEY, WATER, DISTILLED VINEGAR, SUGAR, TOMATO CONCENTRATE, HA
    Category
    Food
    Distribution
    45 states
  • HighFDA (Devices)·Z-1611-2026·2026-04-01

    Olympus endoscope air water valves no longer compatible with named reprocessors

    Olympus is recalling the MAJ-1444 Endoscope Air/Water Valve because the MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.

    Product
    Olympus Endoscope Air/Water Valve - MAJ-1444. Model Number: MAJ-1444.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0599-2026·2026-04-01

    Ajinomoto Green Gyoza Vegetable Edamame Dumplings Recalled for Glass

    Ajinomoto Foods North America Inc. is recalling Ajinomoto Green Gyoza Vegetable & Edamame Dumplings due to the presence of glass fragments (1–3 cm long and 2–4 mm wide) in the product.

    Product
    Item 6430093 Ajinomoto Green Gyoza Vegetable & Edamame Dumplings 12ct. Retail bag UPC: None. Product packaging is flexible bags in a master case or flexible bags in cartons in a master case. There are 20/12ct. bags per case. Case UPC 10071757080246. All products are intended to
    Category
    Food
    Distribution
    43 states
  • HighFDA (Devices)·Z-1610-2026·2026-04-01

    Olympus endoscope suction valve no longer compatible with named reprocessors

    Olympus is recalling the MAJ-1443 Endoscope Suction Valve because the MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.

    Product
    Olympus Endoscope Suction Valve - MAJ-1443. Model Number: MAJ-1443.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1651-2026·2026-04-01

    Embrace shoulder drill tower surgical technique lists mixed-up article numbers

    Waldemar Link is recalling the Embrace Drill Tower because the surgical technique document has mixed-up article numbers in the instrument overview, although the individual surgical steps are correct.

    Product
    Embrace Drill Tower, Wedged (25mm); Item Number: 645-081/62;
    Category
    Medical Device
    Distribution
    15 states
  • ModerateFDA (Devices)·Z-1645-2026·2026-04-01

    BD Alaris system labeling omits required TLS version for secure Wi-Fi

    CareFusion is recalling the BD Alaris System with Guardrails Suite MX because the product labeling does not indicate which TLS version must be enabled on the hospital network for secure Wi-Fi communication.

    Product
    BD Alaris" System with Guardrails" Suite MX with Point of Care Unit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1631-2026·2026-04-01

    BiDop 3 pocket Doppler labeling includes uncleared fetal indication

    Koven Technology is recalling the BiDop 3 Pocket Doppler packaged with a fetal probe because the product labeling includes a fetal indication for use that is not cleared under its 510(k).

    Product
    Brand Name: BiDop 3 Product Name: BiDop 3 Pocket Doppler (ES-100V3) with BT2M20S8C fetal probe Model/Catalog Number: ES-100V3 (device); BT2M20S8C (2 MHz fetal probe). Software Version: N/A Product Description: Hand-held, battery-powered ultrasonic Doppler blood-flow detector
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0401-2026·2026-04-01

    Sodium iodide capsule packs recalled after failing capsule specifications

    Radnostix is recalling three lots of the Gelatin Capsule Pack used with the Sodium Iodide I-131 Kit because the product failed tablet and capsule specifications.

    Product
    SODIUM IODIDE I-131 — SODIUM IODIDE I-131 (SODIUM IODIDE I-131)
    Category
    Drug
    Distribution