The Recall Desk

State

Louisiana product recalls

20,307 recalls have nationwide distribution and so reach Louisiana. 0 additional recalls listed Louisiana specifically in their distribution scope.

About recalls in Louisiana

Most US product recalls have nationwide distribution — the manufacturer ships into every state and the recall sweeps the same way. We include those in this listing because they affect Louisiana consumers even though the source notice doesn’t name the state. State-specific recalls are usually for products with regional distribution (a regional dairy, a local store brand) or where the agency was able to narrow the affected shipments to specific destinations.

If you’re checking whether a recall affects your purchase, the recall detail page lists the exact production lot codes, UPCs, and best-by dates. Match those against your package — distribution scope is a starting filter, not the final answer.

11101–11125 of 20307

  • SevereFDA (Drugs)·D-0135-2024·2023-11-29

    Eye drops recalled for non-sterility due to bacterial contamination

    Cardinal Health's LEADER brand Dry Eye Relief eye drops are recalled nationwide due to non-sterility concerns. FDA found insanitary conditions and positive bacterial results from environmental sampling at the manufacturing facility.

    Product
    DRY EYE RELIEF — DRY EYE RELIEF (POLYETHYLENE GLYCOL AND PROPYLENE GLYCOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0136-2024·2023-11-29

    LEADER Lubricant Eye Drops Recalled for Non-Sterility and Bacterial Contamination

    Cardinal Health is recalling all lots of LEADER brand Lubricant Eye Drops due to non-sterility issues. FDA found insanitary conditions and positive bacterial test results at the manufacturing facility in India.

    Product
    LEADER brand Lubricant Eye Drops (Propylene Glycol, 0.6%); 0.33 FL OZ (10 mL) dropper bottles, Sterile, Distributed By Cardinal Health, Dublin, Ohio 43017. Made in India NDC: 70000-0587-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0134-2024·2023-11-29

    FDA Recalls LEADER Brand Lubricant Eye Drops Due to Non-Sterility Risk

    Cardinal Health is recalling all lots of LEADER brand Lubricant Eye Drops nationwide due to non-sterility. FDA found insanitary conditions and positive bacterial test results from the manufacturing facility.

    Product
    LUBRICANT DROPS — LUBRICANT DROPS (CARBOXYMETHYLCELLULOSE SODIUM)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0108-2024·2023-11-29

    Lubricating Tears Eye Drops Recalled for Non-Sterility and Bacterial Contamination

    Rugby Laboratories' Lubricating Tears Eye Drops are being recalled nationwide due to non-sterility. FDA found insanitary conditions and positive bacterial test results at the manufacturing facility.

    Product
    Lubricating Tears Eye Drops (Dextran/Hypromellose), 0.1%/0.3%, packaged in 0.5 FL OZ (15mL) bottles, Distributed by: RUGBY LABORATORIES, Livonia, MI 48152, NDC 0536-1282-94
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0232-2024·2023-11-29

    VariSoft Infusion Set recalled for defective connector prone to unintended disconnection

    Unomedical is recalling 8,028 VariSoft infusion sets due to a manufacturing defect that makes the connector prone to unintended disconnection, potentially leading to missed insulin doses and serious blood glucose complications.

    Product
    VariSoft infusion set, Model Number 1002827
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0116-2024·2023-11-29

    FDA Recalls Sodium Bicarbonate Injection for Silicone Particulate Contamination

    Exela Pharma Sciences recalls 8.4% sodium bicarbonate injection nationwide due to silicone particulate matter in vials. The FDA classified this Class I recall as affecting 355,220 vials.

    Product
    SODIUM BICARBONATE — SODIUM BICARBONATE (SODIUM BICARBONATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0332-2024·2023-11-29

    Rhinolaryngoscope Models Recalled for Unvalidated Air Drying Process

    Aizu Olympus rhinolaryngoscopes (models ENF-T3, ENF-VT2, ENF-VT3) are recalled. The air-drying process for the instrument channel was not validated, and water remaining in some devices after repair poses contamination and infection risk.

    Product
    Rhinolaryngoscope-for endoscopic diagnosis and treatment within the nasal lumens and airway anatomy (including nasopharyngeal and trachea). Model Numbers: ENF-T3, ENF-VT2, ENF-VT3.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0384-2024·2023-11-29

    Compress Device Short Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (22 MM) used in orthopedic surgery because they may contain metal burrs in the transverse holes that could prevent drill or pin passage and extend surgical procedures.

    Product
    Compress Device Short Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178564
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0397-2024·2023-11-29

    EXALT Model D Single-Use Duodenoscope Recalled for Lens Fluid Ingress

    Boston Scientific is recalling EXALT Model D Single-Use Duodenoscopes due to fluid ingress in the lens, which causes poor image quality during procedures.

    Product
    EXALT Model D Single-Use Duodenoscope, 2 pack: Outer box UPN# M00542421, Inner box UPN # M00542420 & Outer box UPN# M0054242CE1, Inner box UPN # M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0398-2024·2023-11-29

    Robotic patient positioning system may move unexpectedly after interruption

    The ORION System robotic arm used in radiation therapy may suddenly accelerate or move unexpectedly when motion resumes after an interruption, creating a risk of collision with stationary equipment.

    Product
    ORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for patient positioning in Radiation Therapy, Radiology, or Radiology image-guided treatment environment. Part Number: 1SOPT00003
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0350-2024·2023-11-29

    BD Gravity Infusion Sets Labeled DEHP-Free But Contain DEHP

    BD gravity blood infusion sets labeled as free of DEHP (di(2-ethylhexyl) phthalate) actually contain the substance. The recall affects products distributed worldwide through July 31, 2026.

    Product
    BD gravity sets (Product Name, Catalog #) 32-IN GRAV SET W/0.2 MICRON FILTER BAG ACCESS PORT SS VALVE TEXIUMTM LOW ABSORPTION, Catalog # 4030B-07T and BD GRAVITY BLOOD SET 15 DROP 180 MICRON FILTER SmartSiteTM VALVE NONVENTED, Catalog # 42081E.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0337-2024·2023-11-29

    Hysterofiberscope Model HYF-XP Channel Drying Process Flaw Poses Infection Risk

    Aizu Olympus is recalling HYF-XP hysterofiberscopes because the channel air drying process was not validated. Some repaired units have wet channels that could harbor contamination and pose infection risk.

    Product
    Hysterofiberscope-For endoscopic diagnosis within the uterus. Model Number: HYF-XP.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0349-2024·2023-11-29

    BD Alaris Pump Infusion Sets Contain Undisclosed DEHP

    BD Alaris Pump infusion sets labeled as DEHP-free actually contain di(2-ethylhexyl) phthalate. The worldwide recall affects multiple catalog numbers distributed throughout the US and internationally.

    Product
    BD Alaris Pump infusion sets (Product Name, Catalog #) BD AlarisTM Pump Infusion Set Vented syringe adapter Smallbore Tubing, Catalog # 10010483; BD AlarisTM Pump Infusion Set 1.2 Micron Filter Low Sorbing Tubing (PE Lined) SmartSiteTM Y-site, Catalog # 10010453; BD Alar
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0339-2024·2023-11-29

    Tracheal Videoscope Recall Due to Unvalidated Drying Process

    Aizu Olympus is recalling 61 tracheal videoscopes (Model LF-V) due to an unvalidated air drying process that left water in channels after repair. Water in the endoscope channels may become contaminated and pose an infection risk.

    Product
    Tracheal videoscope- For airway management, which includes observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Number: LF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0362-2024·2023-11-29

    BreathTech Manual Resuscitators Recalled for Integrated Manometer Leak

    SunMed Holdings is recalling BreathTech manual resuscitators because the integrated manometer can leak, allowing patients to rebreathe exhaled CO2 during emergency airway management.

    Product
    Ventlab, LLC BreathTech manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. BreathTech Adult Resuscitator REF #s: BT5107F & BT5104P; 2. BreathTech Child Resuscitator REF #s: BT3030, BT3034, & BT3025; 3. BreathTech Infant Res
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0336-2024·2023-11-29

    Hysterovideoscope Models Recalled Due to Improper Channel Drying Risk

    Aizu Olympus is recalling Hysterovideoscope Model HYF-V units (27 devices) because the channel air drying process was not validated. Water remaining in device channels could pose an infection risk.

    Product
    Hysterovideoscope-For endoscopic diagnosis within the uterus Model Number: HYF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0320-2024·2023-11-29

    Medtronic Mo.Ma Ultra cerebral protection device labeling error recalled

    Medtronic is recalling 2,767 units of the Mo.Ma Ultra Proximal Cerebral Protection Device due to labeling errors on the manifold that result in incorrect identification of inflation and deflation ports.

    Product
    Medtronic Mo.Ma Ultra Proximal Cerebral Protection Device, Model Number MUS0130069X6
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0338-2024·2023-11-29

    Tracheal Fiberscope Airway Management Devices Recalled for Inadequate Channel Drying

    Aizu Olympus is recalling 65 tracheal fiberscope units worldwide due to an unvalidated air drying process. Moisture remaining in device channels after repair could allow contamination and pose an infection risk.

    Product
    Tracheal fiberscope-airway management, which includes observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: LF-DP, LF-GP, LF-TP.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0344-2024·2023-11-29

    Transnasal Esophagovideoscope Recalled Due to Unvalidated Drying Process

    Aizu Olympus is recalling the Transnasal Esophagovideoscope (Model PEF-V) because the channel air drying process was not validated, resulting in some units with wet channels that could cause infection.

    Product
    Transnasal esophagovideoscope-For endoscopy and endoscopic surgery within the esophagus and stomach. Model Number: PEF-V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0386-2024·2023-11-29

    Surgical implant anchor plugs may contain metal burrs affecting insertion

    Biomet's Compress Device Short Anchor Plugs may contain metal burrs in the transverse holes, which can prevent proper insertion of surgical tools and extend surgery time. The affected devices are distributed nationwide and internationally.

    Product
    Compress Device Short Anchor Plug, 24 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178566
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0375-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs in transverse holes that may prevent proper device function during surgery. The defect could result in extended surgical time.

    Product
    Compress Device Segmental Anchor Plug, 20 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178410
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0399-2024·2023-11-29

    ORION Robotic Arm Recalled for Sudden Acceleration and Collision Risk

    The FDA recalls ORION robotic positioning arms used in radiation and radiology due to sudden acceleration or unintended movement that could cause patient collision with treatment room equipment. No injuries reported.

    Product
    ORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for patient positioning in Radiation Therapy, Radiology, or Radiology image-guided treatment environment. Part Number: 1SOPT00009
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0113-2024·2023-11-29

    Buspirone Hydrochloride Tablets Recalled Due To Amlodipine Contamination Risk

    FDA recalls Buspirone Hydrochloride 10 mg tablets due to potential contamination with foreign Amlodipine Besylate tablets. The recall affects 1,344 blister cards distributed nationwide.

    Product
    BUSPIRONE HYDROCHLORIDE — BUSPIRONE HYDROCHLORIDE (BUSPIRONE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0352-2024·2023-11-29

    Roche Tina-quant D-Dimer Test System Recalled for Inaccurate Results

    Roche is recalling Tina-quant D-Dimer Test System kits because they produce elevated results when used with lithium-heparin plasma samples, potentially affecting diagnostic accuracy.

    Product
    Tina-quant D-Dimer Test System, Fibrinogen/Fibrin Degradation Products Assay, Material Numbers 03001245322 - (cobas c 311, 501 and 502; INTEGRA 400 plus), 08105618190 - (cobas c 303 and 503)
    Category
    Medical Device
    Distribution
    Distributed nationwide