The Recall Desk
Agency classClass IIOur severity:HighFDA (Devices)·Z-2285-2024·Announced 2024-07-17

Foot-Ankle Procedure Tray Recalled for Excessive Sterilization Residue

American Contract Systems Inc is recalling 107 units of FOOT ANKLE-LF Procedure tray distributed nationwide due to ethylene oxide and ethylene chlorohydrin residuals exceeding safety limits for permanent-implant devices.

The agency’s classification

FDA (Devices): Class II

Class II is a situation in which use of or exposure to a violative product may cause temporary or medically reversible adverse health consequences, or where the probability of serious adverse health consequences is remote.

This is the agency’s own classification, taken from its notice. The severity score below is our assessment, not the agency’s. How recall classes work

What this means for you

Our assessment, not the agency’s: severity 3/5 (High).

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

Our severity reasoning: Class II recall for sterilization residuals exceeding safety limits for permanent-implant devices. No illnesses or injuries reported; hazard is chemical residue exposure exceeding established standards, fitting the High category for risk-of-harm products without reported injury.

Plain-English summary

American Contract Systems Inc is recalling 107 units of the FOOT ANKLE-LF Procedure tray (Catalog Number CCFA51B) distributed nationwide. The recall was issued because ethylene oxide and ethylene chlorohydrin residuals in the cast padding component exceeded the permitted limits for permanent-implant medical devices.

Ethylene oxide and ethylene chlorohydrin are chemical byproducts of the sterilization process. When these residuals exceed established safety limits, they pose a potential health risk. This product is classified for permanent implantation, which requires stricter residual limits per ANSI/AAMI/ISO 10993-7 (2012) standards.

The recalled units include lot numbers 651231, 983241, 940241, and 901241 (UDI-DI: 00191072193148). Healthcare providers and facilities with these trays should refer to the FDA recall notice for instructions on handling affected inventory.

The recalled product

Product
FOOT ANKLE-LF Procedure tray Catalog Number:CCFA51B
Affected units
107

Is your product affected?

Check your packaging against the codes below. If any of them match, the product is part of this recall.

Lot numbers (1)

  • UDI-DI: 00191072193148 LOT#"s: 651231 983241 940241 901241

Distribution

Distributed nationwide across the United States.

Part of a larger recall action

This product is one of 39 recalled by American Contract Systems Inc under a single FDA (Devices) recall action. The agency files each product separately, so the size of the action is not visible from this page alone.

See all 39 products in this recall →