Louisiana product recalls

73,885 recalls have nationwide distribution and so reach Louisiana. 6,969 additional recalls listed Louisiana specifically in their distribution scope.

What the numbers show

Total
6,969
Critical
1,107
Severe
1,741
Most recent
2026-11-14

Of the 6,969 recalls naming Louisiana we have scored against our rubric, 1,107 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,741 (25%) are Severe.

These figures cover only the 6,969 recalls whose distribution notice names Louisiana specifically. The 73,885 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

64201–64225 of 80854

  • HighFDA (Devices)·Z-1844-2014·2014-07-02

    Puritan Bennett 840 Ventilator Recall for Display Loss

    Nellcor Puritan Bennett is recalling 104 Puritan Bennett 840 Ventilators due to reports of loss of graphical user interface display information while the device continues to provide breath support.

    Product
    Puritan Bennett 840 Ventilator (4-840120DIUU-XX) The PB840 Ventilator System is intended to provide invasive or non-invasive ventilatory support and monitoring for infant, pediatric, and adult patients with respiratory failure or respiratory insufficiency. It is used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1848-2014·2014-07-02

    SteriGear Recalls Urinary Drain Bags Due to Valve Malfunction

    SteriGear is recalling 110,560 urinary drain bags because the valve can close and create negative pressure, potentially blocking urine flow.

    Product
    SteriGear Urinary Drain Bag with Fig Leaf Cover, 2000 ml, REF 10270, The Fig Leaf, SteriGear 362 S. University Avenue, provo, UT 84601, 1-800-398-3259, SteriGear.com, Sterile, EO Urinary Drainage Collection Kit, for Indwelling Catheter. This device is intended to collect the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1849-2014·2014-07-02

    Western VIPR Pressure Regulators Recalled for Cylinder Separation Risk

    Western / Scott Fetzer Company is recalling Model RG3000 and RG4000 Series Valve Integrated Pressure Regulators (VIPR) because they may separate from aluminum cylinders.

    Product
    Model RG3000 and RG4000 Series Valve Integrated Pressure Regulator (VIPR)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1926-2014·2014-07-02

    Siemens Dimension LOCI Troponin I Calibrator Recalled for Result Shifts

    Siemens is recalling Dimension LOCI Troponin I Calibrators because they may cause a 24% upward shift in test results.

    Product
    Siemens Dimension LOCI TNI Troponin I Calibrator RC 621. The LOCI TNI Troponin I Calibrator is an in vitro diagnostic product for the calibration of the cardiac troponin I (TNI) method for the Dimension clinical EXL integrated chemistry system with LOCI module.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1868-2014·2014-07-02

    Integra Recalls Accell Evo3C Bone Matrix Due to Packaging Error

    Integra LifeSciences is recalling 61 units of Accell Evo3C Demineralized Bone Matrix because they were incorrectly packaged in boxes for a different product, creating a risk of improper surgical use.

    Product
    Accell Evo3C Demineralized Bone Matrix, 5 cc, Model Number: 02-6000-050 , Lot Number: 132160. Product Usage: Accell Evo3c Demineralized Bone Matrix Putty is intended for filling voids and gaps in the skeletal system that are not intrinsic to the stability of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1851-2014·2014-07-02

    Teleflex Medical Recalls RUSCH LaserTube Tracheal Tubes for Missing Latex Warning

    Teleflex Medical is recalling RUSCH LaserTube tracheal tubes because the label failed to print a specific caution statement regarding natural rubber latex.

    Product
    RUSCH, LaserTube (Rubber), Laser Resistant Tracheal Tube, cuffed, Teleflex Medical, Willy-Rusch, GmbH. A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1745-2014·2014-07-02

    Philips Brilliance CT Big Bore Recalled for Radio Frequency Emission Tolerance Issues

    Philips is recalling 454 Brilliance CT Big Bore systems because internal testing found radio frequency emissions exceeded IEC 60601-1-2 standards.

    Product
    Brilliance CT Big Bore Oncology Whole Body Computed Tomography X-Ray System & Brilliance CT Big Bore Radiology Whole Body Computed Tomography X-Ray System. Product Usage: The Brilliance CT Big Bore is a Whole Body Computed Tomography X-Ray System which produces…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-2043-2014·2014-07-02

    Princess House Tangerine Appetizer Plate Set Recalled for Cadmium Leaching

    Princess House Inc. is recalling 11,912 sets of Marissa Collection Tangerine Appetizer Plates because they leach cadmium above acceptable levels.

    Product
    Marissa Collection Tangerine Appetizer Plate Set (set of 2). distributed by Princess House Inc., Taunton, MA
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1840-2014·2014-07-02

    Siemens LANTIS System Recall for Unvalidated Operating System Risks

    Siemens is recalling 108 LANTIS linear accelerator systems because using the software with unvalidated operating systems can cause data corruption and incorrect treatment records.

    Product
    Siemens LANTIS System ; LANTIS Commander, 10 Users ; LANTIS 6.1 Commander ; LANTIS 8.3 Commander The intended use of the linear accelerator is to deliver x-ray radiation for therapeutic treatment of cancer.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1855-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks used in dialysis systems because they contain aluminum levels exceeding internal specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-302 Lactate , 40, Potassium 1, Sodium 140, Calcium 3, Magnesium 1, Chloride 105, Glucose (mg/dL) 100, Batch Size (liters): 60 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1843-2014·2014-07-02

    BioFire FilmArray Blood Culture Identification Panel Recalled for False Positives

    BioFire is recalling the FilmArray Blood Culture Identification Panel due to an increased risk of false positive results when used with specific blood culture bottles.

    Product
    FirmArray Blood Culture Identification (BCID) Panel, Model 2.0 The FilmArray Blood Culture Identification (BCID) Panel is a qualitative multiplexed nucleic acid-based in vitro diagnostic test designed to test positive blood cultures to quickly identify the organism that is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1864-2014·2014-07-02

    Philips Ingenia 3.0T MRI Systems Recalled for Incorrect Hardware

    Philips is recalling 18 Ingenia 3.0T MRI systems because incorrect M10 nuts were used instead of stainless steel nuts.

    Product
    Ingenia 3.0T, magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1862-2014·2014-07-02

    Philips Ingenia 3.0T MRI Systems Recalled for Incorrect Nut Components

    Philips is recalling 21 Ingenia 3.0T MRI systems because some were shipped with incorrect M10 nuts instead of A4 stainless steel nuts.

    Product
    Ingenia 3.0T R5, magnetic resonance imaging system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1845-2014·2014-07-02

    Siemens RAD Fluoro Uro System Recalled for Image Malfunction

    Siemens is recalling 76 RAD Fluoro Uro Systems because a software malfunction can cause images to appear very dark, potentially leading to unnecessary repeat examinations.

    Product
    Siemens RAD Fluoro Uro System (Ysio, Luminos dRF, and Uroskop Omnia) with software versions VB10G. Product Usage: Image Intensified Fluoroscopic X-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1861-2014·2014-07-02

    NxStage Dialysate Sack Recalled for Excess Aluminum Levels

    NxStage Medical is recalling 91 cases of dialysate sacks because aluminum levels exceeded internal specifications. The product was distributed in the US and internationally.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-407 Lactate 40, Potassium 1, Sodium 140, Calcium 3, Magnesium 1, Chloride 105, Glucose (mg/dL) 100 Batch Size (liters) 50
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateNHTSA·14V406000·2014-07-02

    Ford Recalls 2014 Transit Connect Vehicles for Missing Brake Fluid Label

    Ford is recalling 2014 Transit Connect vehicles because the brake reservoir cap may lack required text identifying the correct brake fluid. This non-compliance could lead to incorrect fluid usage and brake system damage.

    Product
    FORD — FORD TRANSIT CONNECT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1847-2014·2014-07-02

    Baxter Abacus 3.1 Pharmacy Calculator Software Field Correction

    Baxter is correcting a software error in Abacus 3.1 that may display protein levels 1,000 times lower than actual when using Clinimix 4.25110.

    Product
    Abacus 3.1, Pharmacy Calculator Product Usage: Provide pharmacy calculations for automated compounding.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1856-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks used with the PureFlow SL system because they contain aluminum levels exceeding internal specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-303 Lactate 45, Potassium 1, Sodium 140, Calcium 3, Magnesium 100m Chloride 100m, Glucose (mg/dL) 100 Batch Size (liters) 50 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1411-2014·2014-07-02

    Bausch & Lomb Recalls Sodium Chloride Ophthalmic Ointment Due to Crystallization

    Bausch & Lomb is recalling 35,253 tubes of Sodium Chloride Hypertonicity Ophthalmic Ointment, 5%, due to crystal precipitate formation causing a gritty sensation in the eye.

    Product
    Sodium Chloride Hypertonicity Ophthalmic Ointment, 5%, 1/8 oz. (3.5 g) tube per carton, Distributed by Major Pharmaceuticals, 31778 Enterprise Drive, Livonia, MI 48150, NDC 0904-5315-38, UPC 3 09045 31538 5.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1860-2014·2014-07-02

    NxStage Dialysate Sacks Recalled for Excess Aluminum Levels

    NxStage Medical is recalling dialysate sacks used in home dialysis systems because aluminum levels exceeded internal specifications.

    Product
    NxStage Dialysate Sack (SAK) with Concentrate for Use with PureFlow SL REF: SAK-307 Lactate 40, Potassium 1, Sodium 140, Calcium 3, Magnesium 1, Chloride 105, Glucose (mg/dL) 100 Batch Size (liters) 50 The SAK is one of the disposables used with NxStage PureFlow SL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1842-2014·2014-07-02

    Zimmer Recalls VerSys Hip Stems Due to Material Inspection Failures

    Zimmer, Inc. is recalling 147 VerSys Hip System stems because supplier forgings failed routine material inspections.

    Product
    VerSys¿ Hip System, Beaded Fullcoat Stems, Zimmer, Inc., Warsaw, IN 46581
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1928-2014·2014-07-02

    Alere Triage BNP Calibrators Recalled Due to Mislabeling

    Alere San Diego is recalling BNP calibrators because a Level 5 bottle contains Level 4 material, causing calibration failures.

    Product
    Alere Triage BNP Calibrators for the Beckman Coulter Access Family of Immunoassay Systems, Model No. 98202 The Alere Triage BNP test is intended for use with the Beckman Coulter Access Family of Immunoassay Systems for the In Vitro quantitative measurement of B-type…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1852-2014·2014-07-02

    Spacelabs Qube Compact Monitor Recalled for Network Connection Loss

    Spacelabs Healthcare is recalling Qube Compact Monitors due to a potential loss of network connection when switching to the Qube Docking Station without powering down.

    Product
    Spacelabs Healthcare Qube Compact Monitor, Model 91390. Intended to alert the user to alarm conditions that are reported by Spacelabs Healthcare parameter modules and/or other physiologic monitors via Flexport interfaces.
    Category
    Medical Device
    Distribution
    35 states