The Recall Desk

State

Louisiana product recalls

73,741 recalls have nationwide distribution and so reach Louisiana. 6,965 additional recalls listed Louisiana specifically in their distribution scope.

What the numbers show

Total
6,965
Critical
1,107
Severe
1,739
Most recent
2026-10-28

Of the 6,965 recalls naming Louisiana we have scored against our rubric, 1,107 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,739 (25%) are Severe.

These figures cover only the 6,965 recalls whose distribution notice names Louisiana specifically. The 73,741 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

38876–38900 of 80706

  • HighNHTSA·18V933000·2018-12-27

    Forest River Recalls 2019 Salem and Wildwood Trailers for Fire Risk

    Forest River is recalling 2019 Salem and Wildwood recreational trailers because the power cord hatch is located above the water heater exhaust, which may cause melting and increase fire risk.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-0360-2019·2018-12-26

    Lubrisine eye drops recalled for undeclared colloidal silver and sterility issues

    Results RNA, LLC is recalling Lubrisine eye drops nationwide due to lack of sterility assurance and the presence of undeclared colloidal silver.

    Product
    Lubrisine eye drops (polyethylene glycol 400 0.4% and Propylene glycol 0.3%), 30 ML bottle, Manufactured and Distributed by: Results RNA, LLC, 1272 S 1380 W., Orem, UT 84058, UPC 7 9238230723 4
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0497-2019·2018-12-26

    COVIDIEN Recalls Puritan Bennett 980 Ventilators Due to Software Update Issues

    COVIDIEN LLC is recalling 9,593 Puritan Bennett 980 ventilators worldwide due to a software update affecting external USB drive performance and GUI functionality.

    Product
    Puritan Bennett 980 (PB980) ventilator series: Puritan Bennett" 980 Pediatric Adult Ventilator Puritan Bennett" 980 Neonatal Ventilator Puritan Bennett" 980 Universal Ventilator Product Usage: The Puritan Bennett 980 Series Ventilator is designed for use on patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0337-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of Infants' Ibuprofen because they may contain a higher concentration of the active ingredient.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye Free, Non-staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by: CVS Pharmacy, Inc., One CVS Drive, Woonsocket, RI 02895, UPC 0 50428 39338 3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0626-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Short Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft during use, potentially remaining in the patient.

    Product
    Covidien Emprint Short Percutaneous Antenna with Thermosphere Technology, Material CA15L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0336-2019·2018-12-26

    Tris Pharma Recalls Superpotent Infants' Ibuprofen Suspension

    Tris Pharma is recalling 19,488 bottles of Infants' Ibuprofen due to potential higher-than-labeled ibuprofen concentrations.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye-Free Non-Staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Family Dollar Services, Inc., 10301 Monroe Road, Matthews, NC 28105, NDC 55319-250-23, UPC 0 32251 03374 2.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0335-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of infants' ibuprofen oral suspension because they may contain a higher concentration of the active ingredient.

    Product
    infants* IBUPROFEN, Concentrated Ibuprofen Oral Suspension, USP (NSAID), 50 mg per 1.25 mL, Dye-Free Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Wal-Mart Stores, Inc., Bentonville, AR 72716, NDC 49035-125-23, UPC 0 78742 02016 7.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0333-2019·2018-12-26

    Pharmedium Recalls Sub-Potent Fentanyl and Ropivacaine Injection Syringes

    Pharmedium Services, LLC is voluntarily recalling 295 syringes of a fentanyl and ropivacaine injection that were found to be sub-potent.

    Product
    Fentanyl Citrate 2 mcg per mL (100 mcg per 50 mL) and Ropivacaine HCl 0.1% in Sodium Chloride 0.9%, Injection, 50 mL total volume in a 60 mL BD Syringe, Rx Only, PharMEDium Services, LLC. 913 N. Davis Ave. Cleveland, MS 38732 NDC 61553-644-75.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0627-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Ablation Antenna Due to Tip Disengagement

    FDA is recalling the Covidien Emprint Standard Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Standard Percutaneous Antenna with Thermosphere Technology, CA20L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0338-2019·2018-12-26

    Gordon Laboratories Recalls Monsel's Solution Due to High Iron Levels

    Gordon Laboratories is recalling specific batches of Monsel's (Ferric Subsulfate) Solution because they contain higher levels of iron than labeled.

    Product
    Monsel's (Ferric Subsulfate) Solution, 8 mL amber glass bottle, packaged as one dozen bottles with applicators per box, Rx only, Gordon Laboratories, Upper Darby, PA 19082, NDC 10481-0112-8.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0625-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Long Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Long Percutaneous Antenna with Thermosphere Technology, Material CA30L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0734-2019·2018-12-26

    Country Favor Recalls Best Taste Dried Bamboo Shoots for Undeclared Sulfites

    Country Favor Inc. is recalling Best Taste Brand Dried Bamboo Shoots because the product contains undeclared sulfites. The recall affects 81 cases distributed across 23 states.

    Product
    Best Taste Brand DRIED BAMBOO SHOOT Mang Non. The product comes in a 12 ounce (340g) uncoded flexible plastic package with UPC: 6 9709 999 40196. Product of P.R.C.
    Category
    Food
    Distribution
    22 states
  • SevereFDA (Drugs)·D-0334-2019·2018-12-26

    Pharmedium Recalls Sub-Potent Fentanyl and Ropivacaine Injection Bags

    Pharmedium Services, LLC is voluntarily recalling 295 bags of Fentanyl Citrate and Ropivacaine HCl injection because the product was found to be sub-potent.

    Product
    Fentanyl Citrate 2 mcg per mL (200 mcg per 100 mL) and Ropivacaine HCl 0.2% in Sodium Chloride 0.9%, Injection, 100 mL total volume in a 150 mL Intravia Bag, Rx Only,PharMEDium Services, LLC. 913 N. Davis Ave. Cleveland, MS 38732. NDC 61553-148-48
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0617-2019·2018-12-26

    Siemens Dimension Vista 1500 Recalled for Potential Sample Contamination

    Siemens is recalling Dimension Vista 1500 instruments due to a software issue that may cause sample contamination if tests are manually cancelled during aliquoting.

    Product
    Dimension Vista 1500, Model No. 10444801 an in vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determine a variety of analytes in human body fluids.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0742-2019·2018-12-26

    ASK Foods Recalls Rotini Salad Due to Listeria and Salmonella Risk

    ASK Foods Inc is recalling Taste of Inspirations Rotini Salad due to potential contamination with Listeria monocytogenes or Salmonella.

    Product
    Taste of Inspirations Rotini Salad, Net Wt. 13 oz., Pre-pack Container sold to consumer by retailer, 4 lb. Bulk Container sold from the deli
    Category
    Food
    Distribution
    20 states
  • HighFDA (Devices)·Z-0652-2019·2018-12-26

    Ortho-Clinical Diagnostics Recalls VITROS 3600 Immunodiagnostic System Software

    Ortho-Clinical Diagnostics is recalling VITROS 3600 Immunodiagnostic System units due to a software anomaly that may incorrectly extend reagent stability time.

    Product
    VITROS¿ 3600 Immunodiagnostic System, Version 3.3.1 & below For use in the in vitro quantitative measurement of a variety of analytes of clinical interest in certain biological fluids (depending on the analyte) such as serum, plasma, urine and cerebrospinal fluid.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0639-2019·2018-12-26

    bioMerieux Recalls VITEK 2 Systems Software Version 9.01 Update Kit

    bioMerieux is recalling VITEK 2 Systems Software Version 9.01 Update Kits because they may display incorrect organism identification and antimicrobial susceptibility testing results.

    Product
    VITEK¿ 2 Systems Software Version 9.01 Update Kit.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0743-2019·2018-12-26

    ASK Foods Recalls Smokey Mozzarella Pasta Salad Due to Contamination Risk

    ASK Foods Inc. is recalling 4 lb. bulk containers of Smokey Mozzarella Pasta Salad due to potential contamination with Listeria monocytogenes or Salmonella.

    Product
    ASK Foods Inc. Smokey Mozzarella Pasta Salad, 4 lb. Bulk Container sold from the deli and to food service accounts
    Category
    Food
    Distribution
    20 states
  • HighFDA (Food)·F-0746-2019·2018-12-26

    ASK Foods Firecracker Slaw Recalled for Listeria and Salmonella Contamination

    ASK Foods Inc. is recalling Firecracker Slaw due to potential contamination with Listeria monocytogenes or Salmonella. The product was sold in bulk containers from delis in multiple states.

    Product
    ASK Foods Inc. Naturally Creative Firecracker Slaw, 3.75 lb. Bulk Container sold from the deli
    Category
    Food
    Distribution
    20 states
  • HighFDA (Food)·F-0744-2019·2018-12-26

    ASK Foods Rigatoni Casserole Recalled for Listeria and Salmonella Risk

    ASK Foods Inc. is recalling Rigatoni Casserole due to potential contamination with Listeria monocytogenes or Salmonella.

    Product
    ASK Foods Inc. Rigatoni Casserole, 5 lb. Aluminum Tray Pan sold on Hot Bar at Retailer
    Category
    Food
    Distribution
    20 states
  • HighFDA (Devices)·Z-0645-2019·2018-12-26

    Deerfield Imaging Recalls IMRIS T2X Tables Due to Roll Position Drift

    Deerfield Imaging is recalling 15 IMRIS T2X tables because they may drift in the roll position while in use.

    Product
    IMRIS T2X table, Part Numbers: (a)108000-000, (b)108000-600, (c)109682-000, (d) 109682-600, (e) 110470-600 - Product Usage: The ORT200 and ORT300 are intended for use during diagnostic examinations, radiologic procedures, or surgical procedures to support and position a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0648-2019·2018-12-26

    Deerfield Imaging Recalls IMRIS ORT 300 Operating Room Tables

    Deerfield Imaging is recalling 14 IMRIS ORT 300 operating room tables because they may drift in the roll position while in use.

    Product
    IMRIS ORT 300, Removable Operating Room Table, Part Numbers: (a) 114093-000, (b) 114093-006 - Product Usage: The ORT200 and ORT300 are intended for use during diagnostic examinations, radiologic procedures, or surgical procedures to support and position a patient. The tables…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0659-2019·2018-12-26

    Konica Minolta Recalls 151 X-Ray Systems Due to Unintentional Movement

    Konica Minolta is recalling 151 Advanced Universal U-Arm 4000 X-ray systems because the U-Arm may move unintentionally.

    Product
    Bucky Stand SU-4000 Input 2017.11.17. SU41711085 Date: 2017-11-17; Board Name; Board Version, Firmware Version Advanced Universal U-Arm 4000 System. The Positioner consists of the following associated subassemblies: Vertical Column, Swivel Arm with variable height, X-ray…
    Category
    Medical Device
    Distribution
    Distributed nationwide