  • HighFDA (Devices)·Z-1598-2026·2026-04-01

    I.T.S. straight and forearm plates heat more in MRI than stated

    I.T.S. GmbH is recalling Straight Plates with Angular Stability, including forearm and compression plates, because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    I.T.S. Straight Plate with Angular Stability with the below descriptions and corresponding article numbers. 1. Forearm Plate, Curved; Article Numbers: 21604-6, 21604-9. 2. Forearm Plate, Straight; Article Numbers: 21605-11, 21605-6, 21605-9. 3. Straight Compression Pla
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1602-2026·2026-04-01

    I.T.S. distal humeral plates heat more in MRI than stated

    I.T.S. GmbH is recalling Distal Humeral Plates with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    Distal Humeral Plates with Angular Stability with the below descriptions and corresponding article numbers. 1. Cortical Screw, Locking; Article Numbers: 37351-10-N, 37351-12-N, 37351-14-N, 37351-16-N, 37351-18-N, 37351-20-N, 37351-22-N, 37351-24-N, 37351-26-N, 37351-28-N, 373
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1611-2026·2026-04-01

    Olympus endoscope air water valves no longer compatible with named reprocessors

    Olympus is recalling the MAJ-1444 Endoscope Air/Water Valve because the MAJ-1443 and MAJ-1444 are no longer reprocessing compatible with the OER-Pro and OER-Elite automated endoscope reprocessors.

    Product
    Olympus Endoscope Air/Water Valve - MAJ-1444. Model Number: MAJ-1444.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1632-2026·2026-04-01

    Straumann custom abutments made from wrong bar material after mix-up

    Straumann is recalling Custom Abutment Ti for Straumann RC because a material mix-up meant titanium abutments were manufactured from TAN bar material instead of Titanium Grade 4.

    Product
    Custom Abutment Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 027.4620;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1596-2026·2026-04-01

    I.T.S. pilon and tibia plates heat more in MRI than stated

    I.T.S. GmbH is recalling Pilon Plates with Angular Stability and Anterolateral Tibia Plates because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    Pilonplate with Angular Stability, with the below descriptions and corresponding article numbers. 1. Anterolateral Tibia Plate; Article Numbers: 21311-11, 21311-15, 21311-7, 21312-11, 21312-15, 21312-7. 2. Pilon Plate 4mm; Article Numbers: 21094-10, 21094-4, 21094-6, 2109
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1604-2026·2026-04-01

    I.T.S. distal ulna plates heat more in MRI than instructions state

    I.T.S. GmbH is recalling the Distal Ulna Locking and Ulna Osteotomy Locking Systems because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use reflected.

    Product
    I.T.S. DUL (Distal Ulna Locking) System and UOL (Ulna Osteotomy Locking) System with the below descriptions and corresponding article numbers. 1. I.T.S. DUL (Distal Ulna Locking) System, Distal Ulna Plate; Article Numbers: 21232-3, 21232-4, 21232-6, 21233-3, 21233-4, 21233-6, 21
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1613-2026·2026-04-01

    Olympus OER-Pro reprocessor no longer compatible with two valve models

    Olympus is recalling the OER-Pro Endoscope Reprocessor because the MAJ-1443 and MAJ-1444 air/water valves are no longer reprocessing compatible with the OER-Pro and OER-Elite reprocessors.

    Product
    Olympus Endoscope Reprocessor OER-Pro. Model Number: N3058140.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V208000·2026-04-01

    Volvo trucks recalled over turn signals that may not function properly

    Volvo Trucks North America is recalling 340 VNL and VNR vehicles because the turn signals may not function properly, failing to comply with the federal lighting standard.

    Product
    VOLVO — VOLVO VNL (4), VNR (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·26V207000·2026-04-01

    Mack Recalls 2025-2027 Trailers Due to Turn Signal Software Defect

    Mack Trucks is recalling 2025-2027 Pioneer and 2027 Anthem trailers because turn signals may not function properly, increasing crash risk.

    Product
    MACK — MACK PIONEER PR (4), ANTHEM AN (4)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1639-2026·2026-04-01

    Olympus Everest bipolar cutting forceps jaws may break from defective welds

    Olympus is recalling Everest Bipolar Cutting Forceps because a supplier did not adequately validate the welding process, and defective welds can cause the forceps jaw to break during clinical use.

    Product
    Brand Name: Olympus Everest Bipolar Cutting Forceps w/Cord, 5mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3006 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achi
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0598-2026·2026-04-01

    Kroger Chinese Inspiration Vegetable Fried Rice recalled for glass

    Ajinomoto Foods North America Inc. is recalling Kroger Chinese Inspiration Vegetable Fried Rice due to the presence of glass fragments varying from 1–3 cm long and 2–4 mm wide.

    Product
    Item 81153 Kroger Chinese Inspiration Vegetable Fried Rice - Blend of long grain rice assorted vegetables & egg. Net wt. 22oz. Retail box UPC 011110041623. Product packaging is flexible bags in a master case or flexible bags in cartons in a master case. There are 6/22oz. boxes o
    Category
    Food
    Distribution
    43 states
  • HighFDA (Food)·H-0615-2026·2026-04-01

    Savannah Bee Company Honey BBQ Sauce Mustard Undeclared Allergens

    Savannah Bee Company is recalling Honey BBQ Sauce Mustard bottles containing an undeclared different flavor product with soy and wheat allergens not listed on the label.

    Product
    SAVANNAH BEE COMPANY HONEY BBQ SAUCE MUSTARD NET 16 FL OZ (453g), PACKED IN BOTTLES. INGREDIENTS: MUSTARD (DISTILLED VINEGAR, WATER, MUSTARD SEED, SALT, SPICES (INCLUDING PAPRIKA AND TUMERIC), NATURAL FLAVOR, GARLIC), HONEY, WATER, DISTILLED VINEGAR, SUGAR, TOMATO CONCENTRATE, HA
    Category
    Food
    Distribution
    45 states
  • HighFDA (Food)·H-0589-2026·2026-04-01

    Chilli Spanish Peanuts First Street recalled for glass contamination

    Western Mixers Produce & Nuts, Inc. is recalling First Street Chilli Spanish Peanuts (11 oz) because glass fragments were found in sealed containers. Affected lots have expiration dates of 2/11/2027, 2/13/2027, and 2/23/2027.

    Product
    Chilli Spanish Peanuts, First Street brand, 11oz clear plastic container. UPC: None Item Code: 2608-T20
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1633-2026·2026-04-01

    Straumann angled custom abutments made from wrong bar material

    Straumann is recalling Custom Abutment AS Ti for Straumann RC because a material mix-up meant titanium abutments were manufactured from TAN bar material instead of Titanium Grade 4.

    Product
    Custom Abutment AS Ti, for Straumann RC, incl. TAN screw; Catalog Number/Art.: 010.5438;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1638-2026·2026-04-01

    Olympus Everest bipolar forceps model 3005 jaws may break

    Olympus is recalling Everest Bipolar Cutting Forceps model 3005 because a supplier did not adequately validate the welding process, and defective welds can cause the jaw to break during clinical use.

    Product
    Brand Name: Olympus Everest Bipolar Cutting Forceps, 5 mm 33 cm Product Name: Everest Bipolar Cutting Forceps Model/Catalog Number: 3005 Product Description: The OLYMPUS Everest Bipolar Cutting Forceps are intended to be passed through a 5 mm cannula. Coagulation is achieved u
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1640-2026·2026-04-01

    Olympus PK cutting forceps jaws may break from defective welds

    Olympus is recalling PK Cutting Forceps because a supplier did not adequately validate the welding process, and defective welds can cause the forceps jaw to break during clinical use.

    Product
    Brand Name: Olympus PK Cutting Forceps, 5mm 33cm Product Name: PK Cutting Forceps Model/Catalog Number: PK-CF0533 Product Description: An assembly of devices intended to generate and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation dur
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1594-2026·2026-04-01

    I.T.S. proximal humeral plates heat more in MRI than stated

    I.T.S. GmbH is recalling the Humeral Head Plate with Angular Stability because updated MRI safety testing shows higher RF-induced temperature increases than the Instructions for Use previously reflected.

    Product
    Brand Name: Humeral Head Plate with Angular Stability, with the following description: Proximal Humeral Plate. Article Numbers: 211341-10, 211341-4, 211341-7, 21134-4, 21134-5, 21135-4, 21136-4, 21136-5, 21136-7, 21137-4, 21137-7, 21138-4, 21139-4.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1641-2026·2026-04-01

    Olympus HALO PKS cutting forceps jaws may break from defective welds

    Olympus is recalling HALO PKS Cutting Forceps because a supplier did not adequately validate the welding process, and defective welds can cause the forceps jaw to break during clinical use.

    Product
    Brand Name: Olympus HALO PKS Cutting Forceps, 5mm 33cm Product Name: HALO PKS Cutting Forceps Model/Catalog Number: HACF0533 Product Description: The HALO PKS Cutting Forceps are intended to be passed through a 5 mm laparoscopic cannula. Coagulation is achieved using electro
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0404-2026·2026-04-01

    Teva octreotide acetate 10 mg recalled over sterility assurance deficiencies

    Teva is recalling two lots of Octreotide Acetate for Injectable Suspension 10 mg after quality system deficiencies were identified during an FDA inspection at the contract manufacturer.

    Product
    OCTREOTIDE ACETATE — OCTREOTIDE ACETATE (OCTREOTIDE ACETATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1629-2026·2026-04-01

    Orthalign drill plate sizes 1-5 may allow excessive bone cut

    Orthalign is recalling one lot of the Trimax Pegged Drill Plate sizes 1-5 for the Lantern Knee System because plates manufactured out of specification can result in a bone cut in excess of 0.0800 inches.

    Product
    Drill Plate, Ortho Dev. Trimax - Pegged, PREF Size 1 -5 REF:402566 component Lantern Knee System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1651-2026·2026-04-01

    Embrace shoulder drill tower surgical technique lists mixed-up article numbers

    Waldemar Link is recalling the Embrace Drill Tower because the surgical technique document has mixed-up article numbers in the instrument overview, although the individual surgical steps are correct.

    Product
    Embrace Drill Tower, Wedged (25mm); Item Number: 645-081/62;
    Category
    Medical Device
    Distribution
    15 states
  • ModerateFDA (Devices)·Z-1631-2026·2026-04-01

    BiDop 3 pocket Doppler labeling includes uncleared fetal indication

    Koven Technology is recalling the BiDop 3 Pocket Doppler packaged with a fetal probe because the product labeling includes a fetal indication for use that is not cleared under its 510(k).

    Product
    Brand Name: BiDop 3 Product Name: BiDop 3 Pocket Doppler (ES-100V3) with BT2M20S8C fetal probe Model/Catalog Number: ES-100V3 (device); BT2M20S8C (2 MHz fetal probe). Software Version: N/A Product Description: Hand-held, battery-powered ultrasonic Doppler blood-flow detector
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0401-2026·2026-04-01

    Sodium iodide capsule packs recalled after failing capsule specifications

    Radnostix is recalling three lots of the Gelatin Capsule Pack used with the Sodium Iodide I-131 Kit because the product failed tablet and capsule specifications.

    Product
    SODIUM IODIDE I-131 — SODIUM IODIDE I-131 (SODIUM IODIDE I-131)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1645-2026·2026-04-01

    BD Alaris system labeling omits required TLS version for secure Wi-Fi

    CareFusion is recalling the BD Alaris System with Guardrails Suite MX because the product labeling does not indicate which TLS version must be enabled on the hospital network for secure Wi-Fi communication.

    Product
    BD Alaris" System with Guardrails" Suite MX with Point of Care Unit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1652-2026·2026-04-01

    Embrace standard drill tower surgical technique lists mixed-up article numbers

    Waldemar Link is recalling the Embrace Drill Tower, Standard/Lateral, because the surgical technique document has mixed-up article numbers in the instrument overview, although the surgical steps are correct.

    Product
    Embrace Drill Tower, Standard/Lateral (25mm); Item Number: 645-081/63;
    Category
    Medical Device
    Distribution
    15 states