The Recall Desk

State

Indiana product recalls

73,806 recalls have nationwide distribution and so reach Indiana. 9,598 additional recalls listed Indiana specifically in their distribution scope.

What the numbers show

Total
9,598
Critical
1,908
Severe
2,536
Most recent
2026-11-04

Of the 9,598 recalls naming Indiana we have scored against our rubric, 1,908 (20%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,536 (26%) are Severe.

These figures cover only the 9,598 recalls whose distribution notice names Indiana specifically. The 73,806 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

39801–39825 of 83404

  • HighNHTSA·18V941000·2018-12-31

    Arcimoto Recalls 2017-2018 FUV Motorcycles for Turn Signal Placement

    Arcimoto is recalling 2017-2018 FUV motorcycles because front turn signals are not positioned as required by federal safety standards, potentially reducing visibility.

    Product
    ARCIMOTO — ARCIMOTO FUV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V935000·2018-12-31

    Subaru Recalls 2018 Models for Rearview Camera Software Defect

    Subaru is recalling 2018 Legacy, Outback, and BRZ vehicles because a software issue may prevent the rearview camera from displaying an image while backing up.

    Product
    SUBARU — SUBARU OUTBACK, LEGACY, BRZ
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·125-2018·2018-12-30

    Zeigler Red Hot Sausage Recalled for Metal Contamination

    R. L. Zeigler Co. is recalling Red Hot chicken and pork sausage products due to possible metal contamination. No illnesses have been reported.

    Product
    R. L. Zeigler Co. Inc. — R. L. Zeigler Co., Inc. Recalls Chicken and Pork Red Hot Sausage Products due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V934000·2018-12-28

    Hyundai Recalls Sonata and Santa Fe Sport for Fuel Pipe Fire Risk

    Hyundai is recalling 2011-2014 Sonata and 2013-2014 Santa Fe Sport vehicles because a fuel pipe may leak, increasing the risk of a fire.

    Product
    HYUNDAI — HYUNDAI SONATA, SANTA FE SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V933000·2018-12-27

    Forest River Recalls 2019 Salem and Wildwood Trailers for Fire Risk

    Forest River is recalling 2019 Salem and Wildwood recreational trailers because the power cord hatch is located above the water heater exhaust, which may cause melting and increase fire risk.

    Product
    FOREST RIVER — FOREST RIVER SALEM, WILDWOOD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0775-2019·2018-12-26

    Inspired Organic Sunflower Butter Recalled for Listeria monocytogenes Contamination

    Lipari Foods is recalling Inspired Organic Sunflower Butter because product testing found Listeria monocytogenes. The recall covers 972 cases distributed across 15 states and Canada.

    Product
    Inspired Organic Sunflower Butter 16oz. plastic jar, 6 per case UPC #: 863669742526 refrigerate after opening
    Category
    Food
    Distribution
    15 states
  • CriticalFDA (Drugs)·D-0360-2019·2018-12-26

    Lubrisine eye drops recalled for undeclared colloidal silver and sterility issues

    Results RNA, LLC is recalling Lubrisine eye drops nationwide due to lack of sterility assurance and the presence of undeclared colloidal silver.

    Product
    Lubrisine eye drops (polyethylene glycol 400 0.4% and Propylene glycol 0.3%), 30 ML bottle, Manufactured and Distributed by: Results RNA, LLC, 1272 S 1380 W., Orem, UT 84058, UPC 7 9238230723 4
    Category
    Drug
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0776-2019·2018-12-26

    Lipari Foods Recalls Inspired Organic Almond Butter Due to Listeria

    Lipari Foods is recalling Inspired Organic Almond Butter because product testing found Listeria monocytogenes. Consumers should stop using the product.

    Product
    Inspired Organic Almond Butter 16oz. plastic jar, 6 per case UPC #: 863669742540 refrigerate after opening
    Category
    Food
    Distribution
    15 states
  • CriticalFDA (Food)·F-0777-2019·2018-12-26

    Inspired Organic Tahini Butter Recalled for Listeria monocytogenes Contamination

    Lipari Foods is recalling Inspired Organic Tahini Butter because product testing confirmed the presence of Listeria monocytogenes.

    Product
    Inspired Organic Tahini Butter 16oz. plastic jar, 6 per case UPC #: 863669742564 refrigerate after opening
    Category
    Food
    Distribution
    15 states
  • CriticalFDA (Food)·F-0726-2019·2018-12-26

    Marich Recalls Milk Chocolate Maltballs Due to Undeclared Macadamia Nuts

    Marich Confectionery is recalling 15 lb cases of Milk Chocolate Maltballs because a customer found undeclared macadamia nuts in the shipment.

    Product
    Milk Chocolate Maltballs: NET Wt. 15 lbs. Item number 992 Case UPC 00797817-00992-9 Allergy Information: This product contains Wheat, milk and soy and may contain peanuts and tree nuts.
    Category
    Food
    Distribution
    23 states
  • SevereFDA (Devices)·Z-0497-2019·2018-12-26

    COVIDIEN Recalls Puritan Bennett 980 Ventilators Due to Software Update Issues

    COVIDIEN LLC is recalling 9,593 Puritan Bennett 980 ventilators worldwide due to a software update affecting external USB drive performance and GUI functionality.

    Product
    Puritan Bennett 980 (PB980) ventilator series: Puritan Bennett" 980 Pediatric Adult Ventilator Puritan Bennett" 980 Neonatal Ventilator Puritan Bennett" 980 Universal Ventilator Product Usage: The Puritan Bennett 980 Series Ventilator is designed for use on patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0337-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of Infants' Ibuprofen because they may contain a higher concentration of the active ingredient.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye Free, Non-staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by: CVS Pharmacy, Inc., One CVS Drive, Woonsocket, RI 02895, UPC 0 50428 39338 3.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0626-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Short Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft during use, potentially remaining in the patient.

    Product
    Covidien Emprint Short Percutaneous Antenna with Thermosphere Technology, Material CA15L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0336-2019·2018-12-26

    Tris Pharma Recalls Superpotent Infants' Ibuprofen Suspension

    Tris Pharma is recalling 19,488 bottles of Infants' Ibuprofen due to potential higher-than-labeled ibuprofen concentrations.

    Product
    Infants' Ibuprofen, Concentrated Ibuprofen Oral Suspension, USP, (NSAID), 50 mg per 1.25 mL, Dye-Free Non-Staining Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Family Dollar Services, Inc., 10301 Monroe Road, Matthews, NC 28105, NDC 55319-250-23, UPC 0 32251 03374 2.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0335-2019·2018-12-26

    Tris Pharma Recalls Infants' Ibuprofen Due to Higher Concentration

    Tris Pharma is recalling specific lots of infants' ibuprofen oral suspension because they may contain a higher concentration of the active ingredient.

    Product
    infants* IBUPROFEN, Concentrated Ibuprofen Oral Suspension, USP (NSAID), 50 mg per 1.25 mL, Dye-Free Berry Flavor, 0.5 FL OZ (15 mL) bottle, Distributed by Wal-Mart Stores, Inc., Bentonville, AR 72716, NDC 49035-125-23, UPC 0 78742 02016 7.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0333-2019·2018-12-26

    Pharmedium Recalls Sub-Potent Fentanyl and Ropivacaine Injection Syringes

    Pharmedium Services, LLC is voluntarily recalling 295 syringes of a fentanyl and ropivacaine injection that were found to be sub-potent.

    Product
    Fentanyl Citrate 2 mcg per mL (100 mcg per 50 mL) and Ropivacaine HCl 0.1% in Sodium Chloride 0.9%, Injection, 50 mL total volume in a 60 mL BD Syringe, Rx Only, PharMEDium Services, LLC. 913 N. Davis Ave. Cleveland, MS 38732 NDC 61553-644-75.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0627-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Ablation Antenna Due to Tip Disengagement

    FDA is recalling the Covidien Emprint Standard Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Standard Percutaneous Antenna with Thermosphere Technology, CA20L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0778-2019·2018-12-26

    Lipari Foods Recalls Inspired Organic Peanut Butter for Listeria

    Lipari Foods Operating Company, LLC is recalling Inspired Organic Peanut Butter after product testing returned positive results for Listeria monocytogenes.

    Product
    Inspired Organic Peanut Butter 16oz. plastic jar, 6 per case UPC #: 863669742588 refrigerate after opening
    Category
    Food
    Distribution
    15 states
  • SevereFDA (Drugs)·D-0338-2019·2018-12-26

    Gordon Laboratories Recalls Monsel's Solution Due to High Iron Levels

    Gordon Laboratories is recalling specific batches of Monsel's (Ferric Subsulfate) Solution because they contain higher levels of iron than labeled.

    Product
    Monsel's (Ferric Subsulfate) Solution, 8 mL amber glass bottle, packaged as one dozen bottles with applicators per box, Rx only, Gordon Laboratories, Upper Darby, PA 19082, NDC 10481-0112-8.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0625-2019·2018-12-26

    FDA Recalls Covidien Emprint Percutaneous Antenna Due to Tip Disengagement

    FDA is recalling specific lots of the Covidien Emprint Long Percutaneous Antenna because the ceramic trocar tip may disengage from the needle shaft, potentially remaining in the patient.

    Product
    Covidien Emprint Long Percutaneous Antenna with Thermosphere Technology, Material CA30L2 intended for use in percutaneous, laparoscopic, and intraoperative coagulation (ablation) of soft tissue, including partial or complete ablation of nonresectable liver tumors.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0334-2019·2018-12-26

    Pharmedium Recalls Sub-Potent Fentanyl and Ropivacaine Injection Bags

    Pharmedium Services, LLC is voluntarily recalling 295 bags of Fentanyl Citrate and Ropivacaine HCl injection because the product was found to be sub-potent.

    Product
    Fentanyl Citrate 2 mcg per mL (200 mcg per 100 mL) and Ropivacaine HCl 0.2% in Sodium Chloride 0.9%, Injection, 100 mL total volume in a 150 mL Intravia Bag, Rx Only,PharMEDium Services, LLC. 913 N. Davis Ave. Cleveland, MS 38732. NDC 61553-148-48
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0617-2019·2018-12-26

    Siemens Dimension Vista 1500 Recalled for Potential Sample Contamination

    Siemens is recalling Dimension Vista 1500 instruments due to a software issue that may cause sample contamination if tests are manually cancelled during aliquoting.

    Product
    Dimension Vista 1500, Model No. 10444801 an in vitro diagnostic device intended to duplicate manual analytical procedures such as pipetting, mixing, heating, and measuring spectral intensities to determine a variety of analytes in human body fluids.
    Category
    Medical Device
    Distribution
    Distributed nationwide