The Recall Desk

State

Connecticut product recalls

73,366 recalls have nationwide distribution and so reach Connecticut. 6,572 additional recalls listed Connecticut specifically in their distribution scope.

What the numbers show

Total
6,572
Critical
838
Severe
1,881
Most recent
2026-09-30

Of the 6,572 recalls naming Connecticut we have scored against our rubric, 838 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,881 (29%) are Severe.

These figures cover only the 6,572 recalls whose distribution notice names Connecticut specifically. The 73,366 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

17451–17475 of 79938

  • ModerateCPSC·23185·2023-04-20

    Rollerblade Fury Inline Skates Recalled Due to Fall Hazard

    Rollerblade USA is recalling about 13,400 Fury Inline Skates because the rear brake support can fracture or separate, reducing stability and increasing the risk of falls. No injuries have been reported to date.

    Product
    Rollerblade® Fury Inline Skates and Rollerblade® Fury brake supports
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-0705-2023·2023-04-19

    Frozen Organic Strawberries Recalled Due to Hepatitis A Contamination

    Multiple brands of frozen organic strawberries are being recalled due to potential hepatitis A contamination. The recall affects products distributed across the United States.

    Product
    Simply Nature Organic Strawberries, frozen, net wt. 24 oz., 8 packages per case. UPC 4099100256222. Product of Mexico. Distributed by Aldi Batavia, IL Vital Choice Organic Strawberries, frozen, net wt. 16 oz., 20 packages per case. UPC 834297005024. Product of Mexico.…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0703-2023·2023-04-19

    Frozen Organic Strawberries Recalled for Potential Hepatitis A Contamination

    Frozen Organic Strawberries sold under multiple brands (Kirkland Signature, Trader Joe's, and others) are being recalled due to potential hepatitis A contamination. Do not consume; discard or return to retailer.

    Product
    Frozen Organic Strawberries, Kirkland Signature, frozen, net wt. 4lb., 9 packages per case, Costco Item 904984. UPC 096619140404. Distributed by Costco Warehouse Corporation, Seattle, WA. Product of Mexico.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereNHTSA·23V280000·2023-04-19

    Volvo VNR Electric Trucks Recalled for Battery Cooling System Fire Risk

    Volvo Trucks is recalling certain 2020-2024 VNR electric vehicles. A faulty battery coolant line could cause electrical shorts and fire. Owners should contact Volvo for free battery inspection and replacement.

    Product
    VOLVO — VOLVO VNR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0704-2023·2023-04-19

    Trader Joe's Frozen Tropical Fruit Blend Recalled for Hepatitis A Risk

    Scenic Fruit Company is recalling Trader Joe's Organic Tropical Fruit Blend and related products distributed nationwide and regionally due to potential Hepatitis A contamination from Mexican strawberries. Five lot numbers with Best By dates from April to June 2024 are affected.

    Product
    Trader Joes Organic Tropical Fruit Blend, frozen, net wt. 16 oz., 24 bags per case, SKU 051191. UPC 00511919. This product contains strawberries from Mexico. Distributed by Trader Joe's Monrovia, CA.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1350-2023·2023-04-19

    First Response Easy Read App unable to reliably read pregnancy test results

    Church & Dwight's Easy Read App for pregnancy test sticks may fail to display test results or misread them, leading to false positive or false negative results. The app was marketed without required FDA clearance.

    Product
    Easy Read App associated with First Response Pregnancy Test Sticks - Intended use of converting analog pregnancy test results into text pregnant or not pregnant for display on consumer devices (e.g., smart phone, iPad)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1363-2023·2023-04-19

    Inflatable Penile Prosthesis Risk of Premature Pump Failure

    Coloplast's Titan Touch NB Scrot Zero 16cm prosthesis has been recalled due to decreased wall thickness that could cause premature pump failure. The defect was identified in specific lot units distributed worldwide.

    Product
    Titan Touch NB Scrot Zero 16cm, Catalog Number EN29162400; inflatable penile Prosthesis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0707-2023·2023-04-19

    Impossible Chicken Nuggets Recalled for Possible Wood Fragments

    Impossible Foods Inc is recalling 128,029 cases of Impossible Chicken Nuggets nationwide due to possible wood fragments in the product, which pose a choking and injury risk.

    Product
    Impossible Chicken Nuggets Made From Plants, 2x5 lb Bags. Item No. 60-00031. Net Wt.: 10 lb (4.5kg). Not for retail sale. Fully Cooked. Perishable, Keep Frozen. Distributed by: Impossible Foods, Inc., Redwood City, CA 94063.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·23V279000·2023-04-19

    Triple E RV Recalls 2020-2023 Wonder Motorhomes for Bed Bracket Defect

    Triple E RV is recalling 2020-2023 Wonder W24RTB motorhomes because an incorrectly installed bed stay bracket may fail, causing the bed lid to fall and increasing injury risk.

    Product
    TRIPLE E RV — TRIPLE E RV WONDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1371-2023·2023-04-19

    Inflatable Penile Prosthesis Recall Due to Potential Pump Failure Risk

    Coloplast is recalling certain inflatable penile prostheses due to decreased wall thickness that may cause premature pump failure. No injuries have been reported.

    Product
    Titan Touch Scro Zero Ang 22cm, Catalog Number ES29222400; inflatable penile Prosthesis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0719-2023·2023-04-19

    Animal Crackers in Meal Kits May Contain Metal Shavings

    E S Foods is recalling 1,044,918 meal kits nationwide due to potential bronze metal shavings in the animal crackers component. Consumers should not consume affected product.

    Product
    61498 Cheese Stick with Marinara Sauce with 2 Grains MB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0698-2023·2023-04-19

    Zone Perfect Fudge Graham bars recalled for hard plastic fragments

    Abbott Laboratories is recalling Zone Perfect Fudge Graham bars due to potential hard plastic fragments in the product. Affected bars were distributed to 36 U.S. states.

    Product
    Zone Perfect Fudge Graham bar 50g bars packaged in foil wrapped- 12 bars individually wrapped per cardboard carton
    Category
    Food
    Distribution
    35 states
  • HighFDA (Devices)·Z-1382-2023·2023-04-19

    Philips DigitalDiagnost C50 Radiographic System Ceiling Suspension Malfunction Risk

    The Philips DigitalDiagnost C50 radiographic system's ceiling suspension may descend unintentionally if annual maintenance is skipped and power is interrupted, potentially injuring patients and operators.

    Product
    Philips DigitalDiagnost C50 -intended for use in generating radiographic images of human anatomy Model Number : 712201
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1390-2023·2023-04-19

    Unsterile Plain Gut Absorbable Sutures Recalled Due to Sterilization Defect

    Covidien recalled 3,228 units of Plain Gut Absorbable Sutures due to a sterilization defect. Unsterile sutures may cause infection or vision loss in eye surgery.

    Product
    Plain Gut Absorbable Sutures, PLAIN GUT 5/0 18 P-13 X12 (SG-5686), PLAIN GUT 4-0 18 UD SC-11 DA (SG828-2)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1379-2023·2023-04-19

    Swan-Ganz Thermodilution Catheter May Bend and Cause Monitor Error

    Edwards Lifesciences is recalling Swan-Ganz CCOmbo V thermodilution catheters because the distal end may bend beyond its intended curvature, potentially causing the patient monitoring device to display an error message.

    Product
    Edward Lifesciences, REF 777F8, Swan-Ganz CCOmbo V, CCO/SvO2/CEDV/VIP, Thermodilution Catheter, Exterior Diameter 8F (2.7mm), Usable Length 110 cm, Recommended Guidewire size 0.018 (0.46mm), Minimum Introducer size 9F (3.0 mm)
    Category
    Medical Device
    Distribution
    50 states
  • HighFDA (Devices)·Z-1375-2023·2023-04-19

    Titan inflatable penile prosthesis recalled due to premature pump failure risk

    Coloplast is recalling the Titan 0-Deg inflatable penile prosthesis due to decreased pump wall thickness that may cause premature device failure. The recall affects 23 units distributed worldwide.

    Product
    Titan 0-Deg Scrotal 22 Cm, Catalog Number ES89222400; inflatable penile Prosthesis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0723-2023·2023-04-19

    Animal Crackers in Meal Kits Recalled Due to Possible Metal Shavings

    E S Foods is recalling animal crackers in meal kits distributed nationwide because they may contain bronze metal shavings that could cause choking or internal injury if ingested.

    Product
    61151 Apple Muffin Top TSMB
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1366-2023·2023-04-19

    Inflatable penile prosthesis recalled due to pump wall thickness manufacturing defect

    Coloplast is recalling Titan NB inflatable penile prostheses with reduced pump wall thickness that may cause premature pump failure during normal use.

    Product
    Titan NB Scrotal Zero Ang 18cm, Catalog Number EN88182400; inflatable penile Prosthesis
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1378-2023·2023-04-19

    BioPlex 2200 Anti-CCP Reagent Kit recalled due to reduced test specificity

    Bio-Rad is recalling BioPlex 2200 Anti-CCP reagent kits due to reduced specificity that may cause false positive results. Four customer complaints documented discrepant results during validation testing.

    Product
    BioPlex 2200, Anti-CCP Calibrator Set, REF 663-3200, IVD
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0717-2023·2023-04-19

    Butterball Turkey Stick Meal Kits Recalled for Possible Metal Shavings

    E S Foods is recalling Butterball Turkey Stick meal kits nationwide due to possible bronze metal shavings in the animal crackers. Consumers should not consume these products.

    Product
    61404 Butterball Turkey Stick MB (meal box)
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0803-2023·2023-04-19

    Protein bars recalled nationwide for undeclared cashew allergen

    Wellness Natural USA Inc. is recalling SimplyProtein peanut butter chocolate crispy bars sold at Costco due to undeclared cashew allergen. 2.46 million boxes are affected.

    Product
    SimplyProtein¿ Peanut Butter Chocolate Crispy 15-1.41 OZ (40 g) bar. (UPC 6 86207 00914 7) Sold in 15-count variety pack with two other flavors (Lemon Coconut and Chocolate Sea Salt) NET WT 21/16 OZ (600 g). Outside carton UPC 6 86207 80906 8. Packaged in a carboard box.…
    Category
    Food
    Distribution
    Distributed nationwide