  • CriticalFDA (Devices)·Z-1319-2026·2026-02-18

    Reprocessed Webster CS catheters recalled over residual material particles

    Medline is recalling 228 units because these lots of reprocessed catheters may contain small particles of residual material.

    Product
    Medline ReNewal Reprocessed Webster CS Catheters: Webster CS Catheter 10 Electrodes 2-8-2mm Spacing w/AutoID w/ EZ Steer BD710DF282CRH; Webster CS Catheter 10 Electrodes, 2-8-2mm Spacing w/ EZ Steer BD710DF282RRH BD710FJ282RRH; Webster CS Catheter 10 Electrodes, 2-8-2mm S
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0324-2026·2026-02-18

    Testosterone 200mg single pellets recalled over potential metal particulate

    Asteria Health is recalling 194,336 pellets of Testosterone, 200 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    Testosterone, 200 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-1200-43.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1340-2026·2026-02-18

    GammaPlan software recalled over plans that may irradiate the wrong location

    Elekta is recalling Leksell GammaPlan versions 11.3 and 11.4 because an error when defining a new stereotactic reference may produce a treatment plan that irradiates the incorrect patient location.

    Product
    Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11,3, 11.4 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0328-2026·2026-02-18

    Testosterone 100mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 4,599 pellets of Testosterone 100mg, Triamcinolone Acetonide 20mcg sterile pellets over the potential presence of metal particulate matter.

    Product
    Testosterone 100mg, Triamcinolone Acetonide 20mcg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC:79559-6100-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0503-2026·2026-02-18

    Peanut butter and grape jelly packs recalled over blue plastic

    Ventura Foods is recalling 929 cases of 2.12oz packs after the firm found pieces of blue plastic in a filter during production.

    Product
    CREAMY PEANUT BUTTER NET WT 1.12 OZ(32g)/GRAPE JELLY NET WT 1 OZ (28g) POCO PAC DISTRIBUTED BY DYMA BRANDS, INC. ATLANTA, GA 30328 CREAMY PEANUT BUTTER NET WT 1.12 OZ(32g)/GRAPE JELLY NET WT 1 OZ (28g) POCO PAC DISTRIBUTED BY DYMA BRANDS, INC. ATLANTA, GA 30328
    Category
    Food
    Distribution
    40 states
  • HighFDA (Devices)·Z-1355-2026·2026-02-18

    Surgeon console displays recalled over firmware that can lose visualization

    Intuitive Surgical is recalling 47 da Vinci 5 Surgeon Console Viewer Displays manufactured with outdated firmware, which may cause loss of the 3D surgical field or complete visualization loss.

    Product
    da Vinci 5 Surgeon Console Viewer Display, ASSY, DV5 CONSOLE, IS5000, Part Number: 380730-45
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0313-2026·2026-02-18

    Estradiol 22mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 133 pellets of ESTRADIOL, 22 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    ESTRADIOL, 22 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-3022-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0315-2026·2026-02-18

    Estradiol 37.5mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 715 pellets of ESTRADIOL, 37.5 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    ESTRADIOL, 37.5 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-3037-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0335-2026·2026-02-18

    Thiamine injection bags recalled over a lack of assurance of sterility

    Fresenius Kabi Compounding is recalling 10,548 bags of thiamine HCl 500 mg in sodium chloride injection over a lack of assurance of sterility.

    Product
    thiamine HCl, 500 mg, 500 mg added to 100 mL, 0.9% Sodium Chloride Injection, USP, Fagron Sterile Services, 20 Dan Road, Canton, MA 02021, NDC 71506-079-56.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0337-2026·2026-02-18

    Vancomycin 2 gram bags recalled over a lack of assurance of sterility

    Fresenius Kabi Compounding is recalling vancomycin HCl 2 grams in 500 mL sodium chloride injection over a lack of assurance of sterility.

    Product
    vancomycin HCl, 2 grams, 2 grams added to 500 mL, 0.9% Sodium Chloride Injection, USP, Fagron Sterile Services, 20 Dan Road, Canton, MA 02021, NDC 71506-019-59.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1327-2026·2026-02-18

    Catheter securement dressing kits recalled over open swabstick seals

    Medline is recalling 1,350 kits of convenience kits containing BD ChloraPrep Triple Swabsticks, which BD determined may exhibit an open seal on the applicator packaging.

    Product
    Medline medical convenience kits packaged as: ADULT CATH SECUREMENT DRSG, Kit SKU DYNDC3109
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0338-2026·2026-02-18

    Oxycodone blister cards recalled over seals that let tablets fall out

    Amerisource Health Services is recalling 31,676 packages of Oxycodone Hydrochloride Tablets 5 mg over card seal defects that let tablets fall out of their cavities.

    Product
    OXYCODONE HYDROCHLORIDE — OXYCODONE HYDROCHLORIDE (OXYCODONE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0325-2026·2026-02-18

    Testosterone 303mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 1,015 pellets of Testosterone, 303 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    Testosterone, 303 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-1303-01.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1339-2026·2026-02-18

    GammaPlan 11.1 recalled over plans that may irradiate the wrong location

    Elekta is recalling Leksell GammaPlan version 11.1 because an error when defining a new stereotactic reference may produce a treatment plan that irradiates the incorrect patient location.

    Product
    Brand Name: Leksell GammaPlan Product Name: Radionuclide RT Treatment planning system Software Version: 11.1 Product Description: Leksell GammaPlan¿ is a computer-based system designed for Leksell Gamma Knife¿ treatment planning.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0504-2026·2026-02-18

    Peanut butter and jam packs recalled over blue plastic pieces

    Ventura Foods is recalling 379 cases of Poco Pac creamy peanut butter and strawberry jam after the firm found pieces of blue plastic in a filter during production.

    Product
    CREAMY PEANUT BUTTER NET WT 1.12 OZ(32g)/STRAWBERRY JAM NET WT 1 OZ (28g) POCO PAC DISTRIBUTED BY DYMA BRANDS, INC. ATLANTA, GA 30328 CREAMY PEANUT BUTTER NET WT 1.12 OZ(32g)/STRAWBERRY JAM NET WT 1 OZ (28g) POCO PAC DISTRIBUTED BY DYMA BRANDS, INC. ATLANTA, GA 30328
    Category
    Food
    Distribution
    40 states
  • HighFDA (Drugs)·D-0310-2026·2026-02-18

    Estradiol 15mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 14,848 pellets of ESTRADIOL, 15 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    ESTRADIOL,15 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-3015-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1328-2026·2026-02-18

    Pediatric catheter securement kits recalled over open swabstick seals

    Medline is recalling 450 kits of convenience kits containing BD ChloraPrep Triple Swabsticks, which BD determined may exhibit an open seal on the applicator packaging.

    Product
    Medline medical convenience kits packaged as: PEDIATRIC CATH SECUREMENT DRSG, Kit SKU DYNDC3108
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1344-2026·2026-02-18

    Azurion 3 M12 systems recalled over tables that may move unexpectedly

    Philips is recalling 291 units of the Azurion 3 M12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 3 M12 System Model Numbers: (1) 722063, (2) 722221, (3) 722229; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0316-2026·2026-02-18

    Testosterone 12.5mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 3,871 pellets of Testosterone, 12.5 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    Testosterone, 12.5 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-1012-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1318-2026·2026-02-18

    Spectral CT 7500 scanners recalled over rotor fasteners that may loosen

    Philips is recalling 3 units of the Spectral CT 7500 on Rails because fasteners attaching the rotor to the gantry bearing may not be torqued to specification.

    Product
    Spectral CT 7500 on Rails; Product Code (REF): 728334;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0319-2026·2026-02-18

    Testosterone 37.5mg pellets recalled over potential metal particulate matter

    Asteria Health is recalling 60,868 pellets of Testosterone, 37.5 mg sterile pellets over the potential presence of metal particulate matter.

    Product
    Testosterone, 37.5 mg, 1 Sterile Pellet, Asteria Health 432 Industrial Ln, Birmingham, AL 35211, NDC: 79559-1037-32.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1314-2026·2026-02-18

    Breast biopsy needles recalled over particulates that can enter tissue

    Hologic is recalling 681,870 Brevera Breast Biopsy System disposable 9 gauge needles because particulates in affected devices can be deposited into breast tissue during use.

    Product
    Brevera Breast Biopsy System Disposable 9 Gauge Needle. Biopsy Instrument.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1334-2026·2026-02-18

    Dressing change trays recalled over open swabstick applicator seals

    Medline is recalling 8,445 kits of convenience kits containing BD ChloraPrep Triple Swabsticks, which BD determined may exhibit an open seal on the applicator packaging.

    Product
    Medline medical convenience kits packaged as: ) LVAD DRESSING CHANGE TRAY, Kit SKU DM320C; 2) PORT AND IO ACCESS DRESSING KI, Kit SKU DT15780A; 3) PORT-A-CATH DRESSING CHANGE TR, Kit SKU DT16615; 4) LARGE BORE CENTRAL LINE DRSG C, Kit SKU DT19660; 5) CENTRAL LINE DRESS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1350-2026·2026-02-18

    Azurion 5 M12 systems recalled over tables that may move unexpectedly

    Philips is recalling 326 units of the Azurion 5 M12 because the table may move unexpectedly when the Reset Geometry button is pressed, even with a table lock active.

    Product
    Azurion 5 M12 System Model Numbers: (1)722227, (2)722231; Software Version Number - All versions: R1.X, R2.X, R3.X
    Category
    Medical Device
    Distribution
    Distributed nationwide