The Recall Desk

State

California product recalls

73,219 recalls have nationwide distribution and so reach California. 13,255 additional recalls listed California specifically in their distribution scope.

What the numbers show

Total
13,255
Critical
1,605
Severe
2,847
Most recent
2026-10-02

Of the 13,255 recalls naming California we have scored against our rubric, 1,605 (12%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,847 (21%) are Severe.

These figures cover only the 13,255 recalls whose distribution notice names California specifically. The 73,219 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

15401–15425 of 86474

  • HighFDA (Devices)·Z-0343-2024·2023-11-29

    Small intestinal videoscope recalled due to inadequate channel drying process

    Aizu Olympus is recalling small intestinal videoscopes (Model SIF-Q180) because the channel air drying process was not properly validated. Water remaining in the channels could cause contamination and infection risk.

    Product
    Small intestinal videoscope-For endoscopy and endoscopic surgery within the upper digestive tract (including the esophagus, stomach, duodenum, and small intestine) by oral insertion or the lower digestive tract (including the anus, rectum, sigmoid colon, colon, ileocecal valve…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0381-2024·2023-11-29

    Biomet Compress Device Anchor Plugs Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs due to metal burrs that may prevent proper surgical installation and extend operation time. Distribution includes US nationwide and eight other countries.

    Product
    Compress Device Short Anchor Plug, 16 MM- Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178558
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0324-2024·2023-11-29

    Solea Laser Surgical Instrument Models 2.0 and 3.0 Recall for Unintended Activation

    Convergent Dental is recalling 39 Solea laser surgical instruments due to potential unintended laser activation without foot pedal depression. No injuries have been reported.

    Product
    Solea Models 2.0 and 3.0 Laser Surgical Instrument, Foot Pedal assembly SUB-00434 with foot pedal CUS-00226 Rev. K reworked
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0366-2024·2023-11-29

    Manual resuscitators recalled due to carbon dioxide rebreathing defect

    SunMed Holdings recalls Ventlab STAT-Check manual resuscitators due to a backwards leak in the integrated manometer allowing CO2 rebreathing, which may impair ventilation. Multiple models (Adult, Infant, Pediatric) are affected and distributed nationwide.

    Product
    Ventlab, LLC STAT-Check manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. STAT-Check Adult Resuscitator REF #: SC9101B; 2. STAT-Check Infant Resuscitator RES #s: SC7101B & SC7101B-M0; 3. STAT-Check Pediatric Resuscitator…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0351-2024·2023-11-29

    BD Extension Sets Mislabeled as DEHP-Free Despite Containing Phthalates

    Certain BD Extension Sets sold as free of DEHP (di(2-ethylhexyl) phthalate) actually contain this restricted phthalate. The products have been distributed worldwide.

    Product
    BD Extension Sets (Product Name, Catalog #) BD SmartSite Filter Extension Set PE lined Standard bore 1 SmartSite bonded 0.2um Large PES Filter 1 PC RLL. L: 16 in PV: 4mL, Catalog # 10013902 BD EXTENSION SET TRI-PORT SMALLBORE TUBING CHECK VALVE 3 SmartSite" VALVES, Catalog…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0340-2024·2023-11-29

    Mobile Airway Scope Recalled Due to Unvalidated Drying Process

    Aizu Olympus has recalled 33 Mobile Airway Scope units due to an unvalidated air drying process. Some repaired units had wet channels, creating a potential risk of contamination and infection.

    Product
    Mobile airway scope-diagnosis and observation to access airway anatomy, endotracheal/endobronchial intubation and management. Model Numbers: MAF-DM2, MAF-GM, MAF-GM2, MAF-TM, MAF-TM2.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0395-2024·2023-11-29

    Philips MRI Gradient Coil Recall Due to Fire and Smoke Risk

    Philips is recalling SmartPath to dStream 1.5T MRI systems due to a potential gradient coil failure that could produce smoke or fire. The recall affects 119 units distributed nationwide and internationally.

    Product
    SmartPath to dStream for 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0396-2024·2023-11-29

    Boston Scientific EXALT Model D Duodenoscope Recall: Fluid Ingress in Lens

    Boston Scientific is recalling certain EXALT Model D Single-Use Duodenoscopes worldwide due to fluid ingress in the lens, which causes poor image quality. Affected devices should not be used; contact the manufacturer.

    Product
    EXALT Model D Single-Use Duodenoscope: Outer box UPN# M00542420 & Outer box UPN# M0054242CE0.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0364-2024·2023-11-29

    RescuMed Manual Resuscitators Recalled for CO2 Rebreathing Risk

    SunMed Holdings recalls RescuMed manual resuscitators due to a backwards leak in the manometer allowing CO2 rebreathing. Affected models distributed nationwide across 32 US states.

    Product
    Ventlab, LLC RescuMed manual resuscitators with integrated manometer, multiple accessory configurations to include: 1. RescuMed Adult Resuscitator REF #s: BVM510-F, BVMB510-10, BVMB510-F, BVMB510S-F; 2. RescuMed Infant Resuscitator REF #s: BVMB710 & BVMB710-F; 3.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0388-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled due to metal burrs

    Biomet is recalling Compress Device Short Anchor Plugs (28 MM, Item 178570) due to potential metal burrs in transverse holes that may prevent surgical instruments from passing through, extending surgery duration.

    Product
    Compress Device Short Anchor Plug, 28 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178570
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·23V804000·2023-11-29

    2024 Tiffin Allegro Bay motorhomes recalled for LPG hose defect

    Tiffin is recalling certain 2024 Allegro Bay and Allegro Open Road motorhomes because a 32-inch LPG hose fitting may not fit correctly, creating a fuel leak risk and fire hazard.

    Product
    TIFFIN — TIFFIN ALLEGRO BAY, ALLEGRO OPEN ROAD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0329-2024·2023-11-29

    Colonoscopes Recalled for Unvalidated Channel Drying Process and Infection Risk

    Aizu Olympus is recalling certain colonoscope models because the channel air drying process was not validated. A small percentage of repaired units had water remaining in the channel, which could lead to infection risk.

    Product
    Colonoscope: for endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum, sigmoid colon, colon and ileocecal valve). Model Numbers: CF-2T160I, CF-2T160L, CF-H170I, CF-H170L, CF-H180AI, CF-H180AL, CF-H180DI, CF-H180DL, CF-H190I, CF-H190L…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0335-2024·2023-11-29

    Hysteroscope Model HYF-1T recalled due to moisture in device channels

    Aizu Olympus is recalling Hysteroscope Model HYF-1T devices because the channel air drying process after repair was not validated. Some returned units had residual moisture that could allow contamination and infection.

    Product
    Hysteroscope-For endoscopic diagnosis within the uterus Model Number: HYF-1T.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0378-2024·2023-11-29

    Biomet Compress Device Anchor Plugs recalled for metal burrs in transverse holes

    Biomet is recalling Compress Device Short Anchor Plugs due to potential metal burrs in the transverse holes that may prevent proper placement of drill pins during surgery, potentially extending surgical time.

    Product
    Compress Device Short Anchor Plug, 10 MM-Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement Item Number: 178552
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0327-2024·2023-11-29

    Bronchoscopes Recalled Due to Inadequate Air Drying Process

    Aizu Olympus recalls bronchoscopes due to unvalidated air drying process. Some returned units after repair contain water in channels, creating infection risk.

    Product
    Bronchoscope-for endoscopy and endoscopic surgery within the airways and tracheobronchial tree. Model Numbers: BF-1T150, BF-1T60, BF-1TH190, BF-1TQ170, BF-3C160, BF-3C40, BF-H190, BF-MP190F, BF-MP60, BF-P150, BF-P190, BF-P60, BF-Q170, BF-Q190, BF-XP190, BF-XP60, BF-XT160…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2024·2023-11-29

    Biomet Compress Anchor Plugs Recalled for Metal Burrs in Transverse Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs (18 MM) due to metal burrs in transverse holes that may prevent proper drill or pin placement, potentially extending surgery time.

    Product
    Compress Device Segmental Anchor Plug, 18 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178408
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0389-2024·2023-11-29

    Philips Achieva 1.5T MRI systems recalled for potential gradient coil fire risk

    Philips is recalling Achieva 1.5T MRI systems due to potential gradient coil failure that could produce smoke and/or fire. Approximately 520 units have been distributed nationwide and internationally.

    Product
    Achieva 1.5T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0387-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug recalled for metal burrs

    Biomet is recalling the Compress Device Short Anchor Plug due to metal burrs in transverse holes that may prevent proper insertion of drill or pins, potentially extending surgical time. No injuries have been reported.

    Product
    Compress Device Short Anchor Plug, 26 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178568
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0353-2024·2023-11-29

    BioFire FilmArray TORCH power switch may fail from electrical arcing

    BioFire FilmArray TORCH diagnostic devices have a power switch that may degrade from internal arcing and carbon buildup, potentially causing electrical short, device overheating, or failure to power on.

    Product
    FilmArray TORCH REF HTFA-ASY-0104. HTFA-ASY-0104 is the BIOFIRE TORCH Base which includes barcode scanner, touch screen computer and USB ports. The BioFire FilmArray Torch (BioFire Torch) is an automated in vitro diagnostic (IVD) device intended for use with FDA-cleared or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0346-2024·2023-11-29

    Olympus endoscopes recalled for potential water contamination in channels

    Aizu Olympus Co., Ltd. is recalling duodenovideoscope models due to an unvalidated channel air drying process. Water remaining in the channels after repair poses a potential contamination risk that could lead to infection.

    Product
    Duodenovideoscope-EndoTherapy accessories (such as a biopsy forceps), and other ancillary equipment for endoscopy and endoscopic surgery Model Numbers: TJF-145, TJF-150, TJF-Q180V, TJF-Q190V.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0341-2024·2023-11-29

    Colonoscopes recalled over unvalidated channel drying process

    Aizu Olympus colonoscopes are being recalled because the air drying process for the instrument channel was not properly validated. Some units returned after repair had moisture in the channel, creating a risk of contamination and infection.

    Product
    Colonoscope-indicated for use within the lower digestive tract (including the anus, rectum, sigmoid colon, colon, and ileocecal valve). Model Numbers: PCF-H180AI, PCF-H180AL, PCF-H190DI, PCF-H190DL, PCF-H190I, PCF-H190L, PCF-H190TI, PCF-H190TL, PCF-HQ190I, PCF-HQ190L…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0383-2024·2023-11-29

    Biomet Compress Device Anchor Plug Recalled for Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (20 MM) because metal burrs in transverse holes prevent surgical instruments from passing through, potentially extending surgery time.

    Product
    Compress Device Short Anchor Plug, 20 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178562
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0342-2024·2023-11-29

    Sigmoidovideoscope models recalled due to improper channel drying process

    Aizu Olympus sigmoidovideoscope (model PCF-S) units are being recalled due to an unvalidated channel drying process. Some repaired units returned with water in channels, risking contamination and infection.

    Product
    Signmoidovideoscope-For endoscopy and endoscopic surgery within the lower digestive tract (including the anus, rectum and sigmoid colon). Model Number: PCF-S.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0385-2024·2023-11-29

    Biomet Compress Device Short Anchor Plug Recalled Due to Metal Burrs

    Biomet is recalling Compress Device Short Anchor Plugs (23 MM) due to potential metal burrs in transverse holes that may prevent proper insertion of surgical instruments, potentially extending surgery time. Distribution includes US and multiple international countries.

    Product
    Compress Device Short Anchor Plug, 23 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178565
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0376-2024·2023-11-29

    Compress Device Anchor Plugs Recalled for Metal Burrs in Surgical Holes

    Biomet is recalling Compress Device Segmental Anchor Plugs due to metal burrs that may prevent surgical instruments from passing through properly. The defect may result in extended surgery time.

    Product
    Compress Device Segmental Anchor Plug, 22 MM-For Correction of revision of unsuccessful osteotomy, arthrodesis, or previous joint replacement. Item Number: 178412
    Category
    Medical Device
    Distribution
    Distributed nationwide