The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

7476–7500 of 114917

  • HighFDA (Devices)·Z-0166-2026·2025-10-22

    Cardiac Workstation 7000 recalled after pinched power module wire caused short

    Philips is recalling 29 Cardiac Workstation 7000 units after environmental stress testing failed because a pinched power module wire inside the housing resulted in a short.

    Product
    Cardiac Workstation 7000; Model Number: 860441;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0151-2026·2025-10-22

    Ceramic femoral heads recalled over packaging that may compromise sterile barrier

    BioPro is recalling 147 ceramic femoral heads over a potential packaging issue that could compromise the sterile barrier and present a risk of infection if implanted.

    Product
    BioPro Femoral Head (Ceramic heads 28-30) Product ID/Description 19023 HEAD FEMORAL CERAMIC 28MM -3 19024 HEAD FEMORAL CERAMIC 28MM +0 19025 HEAD FEMORAL CERAMIC 32MM -3 19026 HEAD FEMORAL CERAMIC 32MM +0 19027 HEAD FEMORAL CERAMIC 32MM +3
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0204-2026·2025-10-22

    Non-DEHP solution sets recalled from one lot because IV sets may leak

    Baxter is recalling 18,720 CLEARLINK System non-DEHP Continu-Flo solution sets from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM NON-DEHP CONTINU-FLO SOLN SET, 96" (2,4 m), Product Code: 2H8519
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0152-2026·2025-10-22

    Ceramic endo modular heads recalled over sterile barrier packaging defect

    BioPro is recalling 147 ceramic Endo Modular Heads over a potential packaging issue that could compromise the sterile barrier and risk infection if implanted.

    Product
    BioPro Endo Head (Ceramic) Product ID/Description 13006 ENDO MODULAR CERAMIC SH 38 13012 ENDO MODULAR CERAMIC SH 51 13013 ENDO MODULAR CERAMIC MD 38 13019 ENDO MODULAR CERAMIC MD 51 13007 ENDO MODULAR CERAMIC SH 41 13008 ENDO MODULAR CERAMIC SH 43 13009 ENDO MODULAR…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0185-2026·2025-10-22

    Eye and cataract packs recalled after being sterilized more than once

    American Contract Systems is recalling cataract, eye, retinal and vitrectomy convenience packs that were re-gassed after a sterilization nonconformance.

    Product
    Medical convenience kits Item Number/Description BFCT04X CATARACT PACK - 205986 CMEY17AI EYE PACK - 213187 CMEY17AI EYE PACK - 213187 CMEY17AI EYE PACK - 213187 PERP25AQ PEI RETINAL PACK-206025 RFEY50AC EYE PACK-206026 UIVT47AS VITRECTOMY SUPPLY
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0198-2026·2025-10-22

    Fourteen inch extension sets recalled from one lot because sets may leak

    Baxter is recalling 2,304 CLEARLINK System straight-type extension sets with a retractable collar from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM EXTENSION SET, Straight-Type Extension Set, Standard Bore, CLEARLINK Luer Activated Valve, Retractable Collar, 14-inch (35 centimeters), Product Code 2C8632
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0192-2026·2025-10-22

    Continu-Flo solution sets recalled across six lots because sets may leak

    Baxter is recalling 473,040 CLEARLINK System Continu-Flo solution sets across six lots because the IV sets may leak.

    Product
    CLEARLINK SYSTEM CONTINU-FLO Solution Set, Non-Vented, two CLEARLINK Luer Activated Valves, Backcheck Valve, 10 drops/mL, 112-inch (2.8 meters), Product Code 2C8519
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0170-2026·2025-10-22

    Basic biopsy trays recalled after entire lot was sterilized more than once

    American Contract Systems is recalling a Basic Biopsy Tray lot that was re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Basic Biopsy Tray, Item Number NMBP44L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0203-2026·2025-10-22

    Paclitaxel infusion sets recalled from one lot because IV sets may leak

    Baxter is recalling 27,072 CLEARLINK System Paclitaxel Sets from one lot because the IV sets may leak.

    Product
    CLEARLINK System Paclitaxel Set, Non-Vented with Polyethylene Lined Tubing and CLEARLINK Luer Activated Valve, 0.2 Micron Filter, CLEARLINK Luer Activated Valve, 10 drops/mL, 107-inch (2.7 meters), Product Code 2R8858
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0201-2026·2025-10-22

    Non-DEHP Continu-Flo sets recalled from one lot because sets may leak

    Baxter is recalling 48,096 CLEARLINK System non-DEHP Continu-Flo solution sets from one lot because the IV sets may leak.

    Product
    CLEARLINK SYSTEM CONTINU-FLO Solution Set, Non-Vented, two CLEARLINK Luer Activated Valves. 10 drops/mL, 96-inch (2.4 meters). Non-DEHP, Product Code 2R8519
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0139-2026·2025-10-22

    TENACIO pumps without InhibiZone recalled over inflation and deflation issues

    Boston Scientific is recalling TENACIO Pump without InhibiZone, UPN 72404420, because of the potential for inflation or deflation performance issues or difficulties.

    Product
    TENACIO Pump without InhibiZone; UPN: 72404420;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0147-2026·2025-10-22

    Linear cutter reloads recalled after devices were shipped unsterilized

    Ethicon Endo-Surgery is recalling three ECHELON LINEAR Cutter Reload 80 mm Blue units because the devices were shipped unsterilized.

    Product
    ECHELON LINEAR Cutters Reload 80 mm Blue, intended for transection, resection, and/or creation of anastomoses, Product Number GLC80
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0135-2026·2025-10-22

    Goniotomy instruments recalled over compromised sterile packaging integrity

    Iantrek is recalling 198 C-Rex UNO Microinterventional Goniotomy Instruments over the potential for compromised integrity of the sterile packaging.

    Product
    C-Rex UNO Microinterventional Goniotomy Instrument. Model Number: CRX-120. Product Description: The C-Rex UNO Microinterventional Goniotomy Instrument is a sterile single use disposable manual surgical instrument used in ophthalmic procedures for ab interno goniotomy and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0036-2026·2025-10-22

    Frozen jumbo shrimp recalled over possible cesium 137 contamination

    Sea Port Products is recalling raw frozen easy peel headless shell-on white shrimp because the shrimp may be contaminated with Cesium-137.

    Product
    Sea Port brand, Raw Frozen Easy Peel Headless Shell-On White Shrimp, Jumbo size 16-20. Product of Indonesia. Distributed by Sea Port Products Corporation, Kirkland, WA. Master Case: 10/2 lbs. bags. Net weight 20lbs. UPC 10659878008617 IQF Inner Bag 2lbs: UPC 6 59878 00861 0…
    Category
    Food
    Distribution
    6 states
  • HighFDA (Devices)·Z-0157-2026·2025-10-22

    LOGIQ P9 ultrasound systems recalled over inaccurate liver steatosis measurements

    GE is recalling 37 LOGIQ P9 R4.5 ultrasound systems running software R4.5.7 because the Ultrasound-Guided Attenuation Parameter measurement may display inaccurate liver steatosis values.

    Product
    LOGIQ P9 R4.5 ultrasound system with system software version R4.5.7., Model Number 5877533
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0108-2026·2025-10-22

    Flow diverter devices recalled over tantalum defect affecting vessel wall apposition

    MicroVention is recalling 467 FRED and FRED X flow diverters over a manufacturing issue with tantalum length or attachment that may leave the device incompletely open or poorly apposed.

    Product
    Flow Re-Direction Endoluminal Devices: FRED 27, REF: FRED5019, FRED5029, FRED4528, FRED4026, FRED5526, FRED4508, FRED5514, FRED3536, FRED3511, FRED5014, FRED3516, MV-F451827; FRED X 27, REF: XFRED4017-MVE, XFRED4528-MVE, MV-F501427X, XFRED4518-MVE, XFRED5526-MVE, XFRED4539-MVE…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0179-2026·2025-10-22

    Gynecology procedure packs recalled after being sterilized more than once

    American Contract Systems is recalling gynecology, laparoscopy and hysteroscopy convenience kits that were re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Medical convenience kits Item Number/Description RCGY52D GYN LAPAROSCOPY SPH 0246965 UIGN82M GYN (PS 907645) UIHY16AE ASC HYSTEROSCOPY PACK (PS 020634)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0143-2026·2025-10-22

    Preconnect pump devices recalled over inflation and deflation performance issues

    Boston Scientific is recalling 172 CXR Preconnect devices with TENACIO Pump and InhibiZone because of the potential for inflation or deflation performance issues or difficulties.

    Product
    CXR Preconnect with TENACIO Pump with InhibiZone; UPNs: (1) UPN: 72404461 (12CM PS IZ), (2) 72404462 (14CM PS IZ), (3) 72404463 (16CM PS IZ), (4) 72404464 (18CM PS IZ), (5) 72404465 (10CM IP IZ), (6) 72404466 (12CM IP IZ), (7) 72404467 (14CM IP IZ), (8) 72404468 (16CM IP IZ)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0186-2026·2025-10-22

    PICC and gastrostomy tube packs recalled after being sterilized more than once

    American Contract Systems is recalling PICC G-Tube convenience packs that were re-gassed after a sterilization nonconformance, without validation for multiple cycles.

    Product
    Medical convenience kits UDPG88W PICC G-TUBE PACK-230209
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0131-2026·2025-10-22

    Carotid stent systems recalled because integrated filter may not fully open

    Contego Medical is recalling 568 Neuroguard IEP carotid stent systems because the integrated filter may not open, or may not fully open, during sheath retraction and filter knob operation.

    Product
    Neuroguard IEP 3 in 1 Carotid Stent and Post-Dilation Balloon System with Integrated Embolic Protection (Neuroguard IEP System), REF: NG-0740-140-2, NG-NV-7-40, NG-0640-140-2, NG-NV-6-40
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0165-2026·2025-10-22

    Cardiac workstations recalled after pinched power module wire caused short

    Philips is recalling 28 Cardiac Workstation 5000 units after environmental stress testing failed because a pinched power module wire inside the housing resulted in a short.

    Product
    Cardiac Workstation 5000; Model Number: 860439;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0132-2026·2025-10-22

    Omnipod 5 app recalled because magnifying a field duplicates typed digits

    Insulet is recalling 174,013 units of the Omnipod 5 iOS app because using the iPhone magnifier on a manual entry field while typing can duplicate a digit.

    Product
    The failure occurs if a user on the Omnipod 5 iOS application selects and holds down on a manual entry field, to magnify the visual field using the magnifying feature of the iPhone, while simultaneously selecting a single number on the keyboard.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0155-2026·2025-10-22

    Ultrasound systems recalled over inaccurate liver steatosis measurement values

    GE is recalling 65 LOGIQ P10 series systems running software R4.5.7 because the Ultrasound-Guided Attenuation Parameter measurement may display inaccurate liver steatosis values.

    Product
    LOGIQ P10 series with software version R4.5.7 Model Number 5877534
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0042-2026·2025-10-22

    Frozen burrito bowl blend recalled because it may contain undeclared shrimp

    One Frozen is recalling 57,240 bags of Good and Gather Southwest-Style Burrito Bowl Blend because the product may contain undeclared shrimp.

    Product
    Good and Gather brand Southwest-Style Burrito Bowl Blend Processed in a facility that also handles shellfish, egg, fish, milk, sesame, soy, tree nut and wheat ingredients
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0138-2026·2025-10-22

    TENACIO pumps with InhibiZone recalled over inflation and deflation issues

    Boston Scientific is recalling 59 TENACIO Pump with InhibiZone units, UPN 72404429, because of the potential for inflation or deflation performance issues or difficulties.

    Product
    TENACIO Pump with InhibiZone; UPN: 72404429;
    Category
    Medical Device
    Distribution
    Distributed nationwide