The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

7926–7950 of 15403

  • HighNHTSA·18V786000·2018-11-08

    Chrysler Recalls 2018 Jeep Wrangler Due to Door Latch Defect

    Chrysler is recalling 2018 Jeep Wrangler four-door vehicles because the right rear door latch may be misaligned, potentially preventing the door from latching properly.

    Product
    JEEP — JEEP WRANGLER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·19714·2018-11-08

    Honda Recalls Pioneer 1000 Vehicles Due to Fire and Burn Hazards

    Honda is recalling approximately 56,000 Pioneer 1000 recreational off-highway vehicles because an incorrectly installed throttle body can ignite, posing fire and burn hazards.

    Product
    Recreational off-highway vehicles (ROVs)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E102000·2018-11-07

    Eaton Recalls Heavy-Duty Truck Clutches Due to Component Failure Risk

    Eaton is recalling specific heavy-duty truck clutches because an internal component may fail, potentially causing unintended vehicle movement and increasing crash risk.

    Product
    POWER TRAIN:CLUTCH ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E100000·2018-11-07

    Dexter Trailer Axle Recall for Insufficient Bearing Grease

    Dexter Axle Company is recalling specific trailer axles because inner hub bearings may lack sufficient grease, risking overheating and failure.

    Product
    POWER TRAIN:AXLE HUBS recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V781000·2018-11-06

    Lotus Recalls 2018 Evora Vehicles for Steering Column Assembly Error

    Lotus is recalling 2018 Evora vehicles because an assembly error may prevent the steering column from collapsing properly in a frontal collision, increasing injury risk.

    Product
    LOTUS — LOTUS EVORA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V785000·2018-11-06

    Keystone Montana Recalled for Potential Brake Fastener Failure

    Keystone is recalling 2019 Montana recreational trailers with the Legacy package because brake fasteners may fail, causing loss of braking ability.

    Product
    KEYSTONE — KEYSTONE MONTANA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V783000·2018-11-06

    Blue Bird Recalls 2017-2019 Vision School Buses Due to Fire Risk

    Blue Bird is recalling 2017-2019 Vision school buses because alternator cables may chafe, causing an electrical short and increasing the risk of a fire.

    Product
    BLUE BIRD — BLUE BIRD VISION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V780000·2018-11-05

    Thor Aria and Venetian Motorhomes Recalled for Brake Caliper Bolts

    Thor Motor Coach is recalling 2018-2019 Aria and Venetian motorhomes because brake caliper mounting bolts may be insufficiently tightened, increasing crash risk.

    Product
    THOR — THOR, THOR MOTOR COACH ARIA, VENETIAN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V779000·2018-11-02

    Triple E Recalls 2019 Unity Motorhomes Due to Brake Line Contact

    Triple E is recalling 2019 Unity motorhomes because a support bracket may contact the brake line, causing fluid leaks and reduced braking ability.

    Product
    TRIPLE E — TRIPLE E UNITY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V774000·2018-11-01

    GM Recalls 2019 Vehicles Due to Air Bag Module Defect

    General Motors is recalling 2019 Buick Encore, Chevrolet Spark, Traverse, and Trax vehicles because the air bag module may not be programmed correctly, preventing deployment in a crash.

    Product
    CHEVROLET — CHEVROLET, BUICK TRAX, SPARK, TRAVERSE, ENCORE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V775000·2018-11-01

    Ford Recalls 2010-2012 Vehicles for Passenger Air Bag Defect

    Ford is recalling specific 2010-2012 vehicles to replace passenger air bag modules that may fail to inflate properly in a crash.

    Product
    LINCOLN — LINCOLN, MERCURY, FORD MKZ, MILAN, FUSION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V778000·2018-11-01

    Mack Recalls 2019 Trucks Due to Potential Steering Shaft Separation

    Mack Trucks is recalling 2019 Anthem, Granite, and Pinnacle vehicles because a loose pinch bolt may allow the steering shaft to separate, causing loss of steering.

    Product
    MACK — MACK PINNACLE (PI/PN), ANTHEM (AN), GRANITE (GR)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V777000·2018-11-01

    Honda and Acura Recall Vehicles for Rear Brake Caliper Coating Defect

    Honda is recalling specific 2016-2019 HR-V, Odyssey, and Acura MDX models because rear brake caliper pistons may have insufficient coating, reducing braking performance.

    Product
    HONDA — HONDA, ACURA HR-V, ODYSSEY, MDX, MDX SPORT HYBRID
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V773000·2018-11-01

    Subaru Recalls 2018 Legacy and Outback for Fuel Display Software Error

    Subaru is recalling 2018 Legacy and Outback vehicles because a software error may cause the fuel gauge to display incorrect levels, increasing the risk of stalling and a crash.

    Product
    SUBARU — SUBARU OUTBACK, LEGACY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V772000·2018-11-01

    Subaru and Scion Recall Issued for Engine Valve Spring Fracture Risk

    Subaru and Toyota are recalling specific 2012-2014 Impreza, BRZ, XV Crosstrek, and FR-S models because engine valve springs may fracture, potentially causing an engine stall that increases crash risk.

    Product
    SCION — SCION, SUBARU FR-S, BRZ, XV CROSSTREK, IMPREZA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V769000·2018-10-31

    Suzuki Recalls 2010-2013 Kizashi Vehicles for Fuel Tank Fire Risk

    Suzuki is recalling 2010-2013 Kizashi vehicles because dust in the vent line may crack the fuel tank, increasing the risk of a fuel leak and fire.

    Product
    SUZUKI — SUZUKI KIZASHI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V770000·2018-10-31

    Forest River Recalls 2018-2019 Buses and RVs for Brake Bolt Issue

    Forest River is recalling 2018-2019 Berkshire RVs and StarTrans/Glaval buses because brake caliper mounting bolts may be insufficiently tightened, increasing crash risk.

    Product
    STARTRANS — STARTRANS, FOREST RIVER, GLAVAL BUS PS2, BERKSHIRE, LEGACY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V767000·2018-10-31

    Keystone Recalls 2019 Crossroads Cruiser Trailers Due to Gas Leak Risk

    Keystone RV Company is recalling 2019 Crossroads Cruiser recreational trailers because the water heater exhaust may allow carbon monoxide or propane gas to enter the living quarters.

    Product
    CROSSROADS — CROSSROADS CRUISER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V771000·2018-10-31

    Kia Recalls 2019 Forte Vehicles for Headlight Aiming Defect

    Kia is recalling 2019 Forte vehicles with LED headlights because they may not be aimed correctly, potentially reducing driver visibility and increasing crash risk.

    Product
    KIA — KIA FORTE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·18V768000·2018-10-31

    Forest River Recalls Motorhomes Due to Windshield Shade Visibility Hazard

    Forest River is recalling specific 2017-2019 motorhomes because the driver's windshield roller shade may unroll unexpectedly, blocking visibility and increasing crash risk.

    Product
    FOREST RIVER — FOREST RIVER BERKSHIRE, CHARLESTON, GEORGETOWN, FR3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V762000·2018-10-30

    Altec Recalls 2009 Aerial Devices Due to Riser Assembly Cracking Risk

    Altec Industries is recalling 2009 LSS 60 and LSS 70 Elevator Aerial devices because the elevator riser assembly may crack and fail, increasing the risk of injury or death.

    Product
    ALTEC — ALTEC AERIAL DEVICE
    Category
    Vehicle
    Distribution
    Distributed nationwide